Separation of ampicillin on polar-endcapped phase: Development of the HPLC method to achieve its correct dosage in cardiac surgery

IF 1.7 4区 化学 Q3 CHEMISTRY, ANALYTICAL Acta Chromatographica Pub Date : 2022-01-27 DOI:10.1556/1326.2021.00957
Vendula Kubíčková, Z. Racova, J. Strojil, P. Šantavý, K. Urbanek
{"title":"Separation of ampicillin on polar-endcapped phase: Development of the HPLC method to achieve its correct dosage in cardiac surgery","authors":"Vendula Kubíčková, Z. Racova, J. Strojil, P. Šantavý, K. Urbanek","doi":"10.1556/1326.2021.00957","DOIUrl":null,"url":null,"abstract":"\n The accurate, simple, and selective reversed phase high performance liquid chromatography (RP-HPLC) has been established and validated for the determination of an antibiotic ampicillin (AMP) in human blood plasma. The SPE extraction was used for the sample preparation. Chromatographic separation was accomplished by a mobile phase containing 15 mM monopotassium phosphate solution of pH 3.3 and methanol (75:25, v/v) in an isocratic mode at a flow rate of 1.4 mL min−1 at 30 °C. The separation was evaluated on a column with a new polar-endcapped C18 stationary phase Arion® Polar C18 or well-known phase Luna® Omega Polar C18. Excellent linearity (R\n 2 0.9998) was shown over range 10–300 mg L−1 with mean percentage recovery 90%. Peak shapes were symmetrical in both columns, Arion® Polar C18 and Luna® Omega Polar C18, with asymmetry factor of 1.0 and 1.4, tailing factor of 1.0 and 1.2, and retention factor of 4.6 and 5.6, respectively. The Arion® Polar C18 was almost 1.4-fold more effective than Luna® Omega Polar C18 phase. The LOQ for ampicillin was achieved 10 mg L−1 for Luna® Omega Polar C18 and 5 mg L−1 for Arion® Polar C18 using 20 µL of a solution containing 0.24 mg mL−1 of cephalexin as an internal standard.\n A number of articles dealing with the determination of ampicillin is limited, therefore, this study showed the HPLC method suitable for the determination of AMP in human blood plasma from patient who underwent elective cardiac surgical revascularization. In addition, the determination of AMP was also performed for the first time using an Arion® Polar C18 column, which effectively separated AMP from other compounds present in human blood plasma. This new polar-endcapped phase can help in separation of polar antibiotics or other polar compounds, which are unsuccessfully separated on conventional C18 column, and thus can help during method development.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2022-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2021.00957","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 3

Abstract

The accurate, simple, and selective reversed phase high performance liquid chromatography (RP-HPLC) has been established and validated for the determination of an antibiotic ampicillin (AMP) in human blood plasma. The SPE extraction was used for the sample preparation. Chromatographic separation was accomplished by a mobile phase containing 15 mM monopotassium phosphate solution of pH 3.3 and methanol (75:25, v/v) in an isocratic mode at a flow rate of 1.4 mL min−1 at 30 °C. The separation was evaluated on a column with a new polar-endcapped C18 stationary phase Arion® Polar C18 or well-known phase Luna® Omega Polar C18. Excellent linearity (R 2 0.9998) was shown over range 10–300 mg L−1 with mean percentage recovery 90%. Peak shapes were symmetrical in both columns, Arion® Polar C18 and Luna® Omega Polar C18, with asymmetry factor of 1.0 and 1.4, tailing factor of 1.0 and 1.2, and retention factor of 4.6 and 5.6, respectively. The Arion® Polar C18 was almost 1.4-fold more effective than Luna® Omega Polar C18 phase. The LOQ for ampicillin was achieved 10 mg L−1 for Luna® Omega Polar C18 and 5 mg L−1 for Arion® Polar C18 using 20 µL of a solution containing 0.24 mg mL−1 of cephalexin as an internal standard. A number of articles dealing with the determination of ampicillin is limited, therefore, this study showed the HPLC method suitable for the determination of AMP in human blood plasma from patient who underwent elective cardiac surgical revascularization. In addition, the determination of AMP was also performed for the first time using an Arion® Polar C18 column, which effectively separated AMP from other compounds present in human blood plasma. This new polar-endcapped phase can help in separation of polar antibiotics or other polar compounds, which are unsuccessfully separated on conventional C18 column, and thus can help during method development.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
氨苄青霉素在极性封端相上的分离:高效液相色谱法在心脏外科手术中的应用
建立了准确、简便、选择性高的反相高效液相色谱法测定人血浆中抗生素氨苄西林(AMP)。样品的制备采用固相萃取法。色谱分离采用流动相进行,流动相中含有15mm磷酸二钾溶液(pH 3.3)和甲醇(75:25,v/v),流速为1.4 mL min - 1,温度为30°C。色谱柱采用新型极性端盖C18固定相Arion®Polar C18或知名相Luna®Omega Polar C18进行分离评估。在10 ~ 300 mg L−1范围内线性良好(r2 0.9998),平均回收率为90%。Arion®Polar C18和Luna®Omega Polar C18色谱柱峰形对称,不对称系数分别为1.0和1.4,残留系数分别为1.0和1.2,保留系数分别为4.6和5.6。Arion®Polar C18比Luna®Omega Polar C18有效近1.4倍。Luna®Omega Polar C18氨苄西林的定量限为10 mg L−1,Arion®Polar C18氨苄西林的定量限为5 mg L−1,使用20µL含有0.24 mg mL−1头孢氨苄的溶液作为内标。关于氨苄西林测定的文章有限,因此,本研究表明HPLC法适用于择期心脏手术血运重建术患者血浆中AMP的测定。此外,还首次使用Arion®Polar C18色谱柱进行了AMP的测定,该色谱柱有效地将AMP与人血浆中存在的其他化合物分离开来。这种新的极性端盖相可以帮助分离极性抗生素或其他极性化合物,这些化合物在传统的C18色谱柱上无法成功分离,因此可以在方法开发过程中提供帮助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Acta Chromatographica
Acta Chromatographica 化学-分析化学
CiteScore
4.00
自引率
0.00%
发文量
55
审稿时长
2.3 months
期刊介绍: Acta Chromatographica Open Access Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.
期刊最新文献
Determination of four dry cough medications in fixed dose form by developed stability indicating liquid chromatography-photodiode array detection Method development and validation of Metformin HCL and Dapagliflozin by using RP-HPLC Determination of fraxetin, fraxin and dimethylfraxetin in rat plasma by UPLC-MS/MS Development of an HPLC-UV method for the simultaneous determination of allantoin and D-panthenol in cosmetic products containing Aloe vera extracts A simple, rapid, and green method for determination of three cholic acids in bio-transformed Jindanfen by HPLC-MS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1