{"title":"Osteosynthesis of fifth metacarpal neck fractures with a photodynamic polymer bone stabilization system","authors":"C. Surke, Rahel L. Meier, L. Haug, E. Vögelin","doi":"10.1177/1753193419880775","DOIUrl":null,"url":null,"abstract":"Metacarpal neck fractures with severe displacement are commonly treated surgically with intramedullary Kirschner wires. We present the results of treatment of fifth metacarpal neck fractures using a light curable intramedullary photodynamic polymer (IlluminOss™, IlluminOss Medical Inc., East Providence, RI, USA). Twenty-nine patients with isolated displaced fifth metacarpal neck fractures were included and followed up for 12–24 weeks. All fractures had radiologically healed after 3 months. In two cases, a secondary loss of reduction was seen, which did not require further correction. During the follow-up period, range of motion of the metacarpophalangeal joint was 89% after 6 weeks and increased to 100% after 3 months compared with the uninjured side. Grip strength improved over time from 61% to 85%. No implant removal was necessary. We conclude that osteosynthesis using an intramedullary photodynamic polymer is a reliable treatment option for displaced fractures of the fifth metacarpal neck. Level of evidence: IV","PeriodicalId":73762,"journal":{"name":"Journal of hand surgery (Edinburgh, Scotland)","volume":"45 1","pages":"119 - 125"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1753193419880775","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of hand surgery (Edinburgh, Scotland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1753193419880775","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
Metacarpal neck fractures with severe displacement are commonly treated surgically with intramedullary Kirschner wires. We present the results of treatment of fifth metacarpal neck fractures using a light curable intramedullary photodynamic polymer (IlluminOss™, IlluminOss Medical Inc., East Providence, RI, USA). Twenty-nine patients with isolated displaced fifth metacarpal neck fractures were included and followed up for 12–24 weeks. All fractures had radiologically healed after 3 months. In two cases, a secondary loss of reduction was seen, which did not require further correction. During the follow-up period, range of motion of the metacarpophalangeal joint was 89% after 6 weeks and increased to 100% after 3 months compared with the uninjured side. Grip strength improved over time from 61% to 85%. No implant removal was necessary. We conclude that osteosynthesis using an intramedullary photodynamic polymer is a reliable treatment option for displaced fractures of the fifth metacarpal neck. Level of evidence: IV