Estimation of multi-infeed HVDC inter converter direct current interaction in close electric proximity

IF 0.6 Q3 ENGINEERING, MULTIDISCIPLINARY Mehran University Research Journal of Engineering and Technology Pub Date : 2023-03-28 DOI:10.22581/muet1982.2302.02
Bilawal Rehman, A. Rehman, W. Khan, Jan Muhammad, Syed Mudassir Hussain
{"title":"Estimation of multi-infeed HVDC inter converter direct current interaction in close electric proximity","authors":"Bilawal Rehman, A. Rehman, W. Khan, Jan Muhammad, Syed Mudassir Hussain","doi":"10.22581/muet1982.2302.02","DOIUrl":null,"url":null,"abstract":"This paper aims at investigating the direct current interaction between various converters of High Voltage Direct Current (HVDC) system, which lie in close electric proximity within the multi-infeed configuration. The interaction between converters in multi-infeed DC system are highly possible events which need to be evaluated in order to avoid the adverse operational results. The various indices such as multi-infeed interaction factor (MIIF) considering AC busbar voltages, local and concurrent commutation failures (CF) in converter stations under different AC disturbances, influence of AC system’s strength on fault recovery time (FRT), transient over-voltage (TOV) under permanent DC faults, voltage and power stability of multi-infeed DC system are comprehensively illustrated in literatures. However, there is lack of literature regarding the investigation of current interaction in multi-infeed DC system. Therefore, in this paper, a power flow approach is adopted to estimate the inter converter direct current interaction. An index, multi-infeed current interaction factor (MICIF) is proposed that can effectively depicts the interaction between converters. The MICIF index is verified through electromagnetic transient simulations of dual infeed HVDC system developed in PSCAD/EMTDC. The results show that MICIF index can accurately assess the interaction between different converter stations of HVDC system under steady and transient states.","PeriodicalId":44836,"journal":{"name":"Mehran University Research Journal of Engineering and Technology","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2023-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mehran University Research Journal of Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22581/muet1982.2302.02","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

This paper aims at investigating the direct current interaction between various converters of High Voltage Direct Current (HVDC) system, which lie in close electric proximity within the multi-infeed configuration. The interaction between converters in multi-infeed DC system are highly possible events which need to be evaluated in order to avoid the adverse operational results. The various indices such as multi-infeed interaction factor (MIIF) considering AC busbar voltages, local and concurrent commutation failures (CF) in converter stations under different AC disturbances, influence of AC system’s strength on fault recovery time (FRT), transient over-voltage (TOV) under permanent DC faults, voltage and power stability of multi-infeed DC system are comprehensively illustrated in literatures. However, there is lack of literature regarding the investigation of current interaction in multi-infeed DC system. Therefore, in this paper, a power flow approach is adopted to estimate the inter converter direct current interaction. An index, multi-infeed current interaction factor (MICIF) is proposed that can effectively depicts the interaction between converters. The MICIF index is verified through electromagnetic transient simulations of dual infeed HVDC system developed in PSCAD/EMTDC. The results show that MICIF index can accurately assess the interaction between different converter stations of HVDC system under steady and transient states.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
近电距离下多馈入高压直流变流器间直流相互作用的估计
本文旨在研究高压直流(HVDC)系统中各变流器之间的直流相互作用,这些变流器在多馈入配置中处于紧密的电邻近状态。在多馈入直流系统中,变流器之间的相互作用是极有可能发生的事件,为了避免不良的运行结果,需要对其进行评估。文献对考虑交流母线电压的多馈相互作用因子(MIIF)、不同交流干扰下换流站的局部和并发换相故障(CF)、交流系统强度对故障恢复时间(FRT)的影响、直流永久故障下的暂态过电压(TOV)、多馈直流系统的电压和功率稳定性等指标进行了全面阐述。然而,关于多馈入直流系统中电流相互作用的研究文献很少。因此,本文采用潮流法来估计变换器间的直流相互作用。提出了一种能够有效描述变换器间相互作用的指标——多馈流相互作用因子(MICIF)。通过PSCAD/EMTDC开发的双馈直流系统的电磁暂态仿真验证了MICIF指标。结果表明,MICIF指标能够准确地评价直流系统在稳态和暂态状态下不同换流站之间的相互作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
76
审稿时长
40 weeks
期刊最新文献
Heat transfer augmentation through engine oil-based hybrid nanofluid inside a trapezoid cavity Sustainable natural dyeing of cellulose with agricultural medicinal plant waste, new shades development with nontoxic sustainable elements Fabrication of low-cost and environmental-friendly EHD printable thin film nanocomposite triboelectric nanogenerator using household recyclable materials Compositional analysis of dark colored particulates homogeneously emitted with combustion gases (dark plumes) from brick making kilns situated in the area of Khyber Pakhtunkhwa, Pakistan Biosorption studies on arsenic (III) removal from industrial wastewater by using fixed and fluidized bed operation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1