Damping techniques for grid-connected converters with LCL filter: an overview

A. D. A. Romão, N. Da Silva
{"title":"Damping techniques for grid-connected converters with LCL filter: an overview","authors":"A. D. A. Romão, N. Da Silva","doi":"10.5433/1679-0375.2021v42n2p227","DOIUrl":null,"url":null,"abstract":"Distributed generation systems, based on renewable energy sources, are typically connected to the main grid by a voltage-source inverter with a low-pass filter. The need for improved efficiency led to the use of third order low-pass filters, such as the LCL configuration, which has resonant behavior. In order to meet energy quality requirements and ensure the systems stability it is necessary to suppress the LCL filters resonance through damping techniques. Therefore, this paper presents an overview of some damping strategies found in literature and its design procedure, applied to a simulated single-phase grid-tied inverter. The comparison of each presented damping methodology characteristics is described, with analysis of advantages and drawbacks for each case.","PeriodicalId":30173,"journal":{"name":"Semina Ciencias Exatas e Tecnologicas","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Semina Ciencias Exatas e Tecnologicas","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5433/1679-0375.2021v42n2p227","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Distributed generation systems, based on renewable energy sources, are typically connected to the main grid by a voltage-source inverter with a low-pass filter. The need for improved efficiency led to the use of third order low-pass filters, such as the LCL configuration, which has resonant behavior. In order to meet energy quality requirements and ensure the systems stability it is necessary to suppress the LCL filters resonance through damping techniques. Therefore, this paper presents an overview of some damping strategies found in literature and its design procedure, applied to a simulated single-phase grid-tied inverter. The comparison of each presented damping methodology characteristics is described, with analysis of advantages and drawbacks for each case.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
带LCL滤波器的并网变流器阻尼技术综述
基于可再生能源的分布式发电系统通常通过带低通滤波器的电压源逆变器连接到主电网。提高效率的需要导致使用三阶低通滤波器,如具有谐振行为的LCL配置。为了满足电能质量要求和保证系统的稳定性,有必要通过阻尼技术抑制LCL滤波器的谐振。因此,本文概述了文献中发现的一些阻尼策略及其设计过程,并将其应用于模拟单相并网逆变器。对每种阻尼方法的特性进行了比较,并分析了每种阻尼方法的优缺点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
12
审稿时长
12 weeks
期刊最新文献
Preliminary observations on gastropod predationnaticids in the eastern Amazon Pigment Identification and Depth Profile in Pictorial Artworks by Non-Invasive Hybrid XRD-XRF Portable System Characterization of Pigments and Materials of the Original Body and Additions of the Book of Hours 50,1,1 from the Brazilian National Library Determination of Cu2+ and Zn2+ in Flaxseed Flour by FAAS and DPASV using Different Sample Treatments Nonlinear Canonical correspondence Analysis: Description of the data of Coffee
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1