Clinical pharmacology, use, and adverse reactions of intravenous iodinated contrast media in computed tomography

D. Brillantino, T. Ferro, C. Brillantino, E. Rossi, R. Minelli, E. Bignardi, A. Tufano, R. Zeccolini, M. Zeccolini
{"title":"Clinical pharmacology, use, and adverse reactions of intravenous iodinated contrast media in computed tomography","authors":"D. Brillantino, T. Ferro, C. Brillantino, E. Rossi, R. Minelli, E. Bignardi, A. Tufano, R. Zeccolini, M. Zeccolini","doi":"10.14312/2399-8172.2020-1","DOIUrl":null,"url":null,"abstract":"Contrast media are substances used in radiology to improve the visualization of certain body structures subjected to analysis in a medical image. Contrast media are, then, diagnostic drugs because they increase the visibility of organs and tissues and allow the identification of details that otherwise could not be observed. With the introduction of multidetector computed tomography the number of patients undergoing contrast studies has grown exponentially in recent years. In computed tomography the formation of the radiographic image is obtained with the use of contrast media containing iodine atoms, exploiting the different attenuation that the X-ray beam presents in crossing the anatomical districts. The iodinated contrast media are a category of numerous substances formed by even complex molecules that vary considerably in their properties, uses and toxic effects. This article describes the clinical pharmacology, use and adverse reactions of intravenous iodinated contrast media used in computerized tomography, offering all doctors, even non-radiologists, the opportunity for rapid updating.","PeriodicalId":73922,"journal":{"name":"Journal of radiology and imaging","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of radiology and imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14312/2399-8172.2020-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Contrast media are substances used in radiology to improve the visualization of certain body structures subjected to analysis in a medical image. Contrast media are, then, diagnostic drugs because they increase the visibility of organs and tissues and allow the identification of details that otherwise could not be observed. With the introduction of multidetector computed tomography the number of patients undergoing contrast studies has grown exponentially in recent years. In computed tomography the formation of the radiographic image is obtained with the use of contrast media containing iodine atoms, exploiting the different attenuation that the X-ray beam presents in crossing the anatomical districts. The iodinated contrast media are a category of numerous substances formed by even complex molecules that vary considerably in their properties, uses and toxic effects. This article describes the clinical pharmacology, use and adverse reactions of intravenous iodinated contrast media used in computerized tomography, offering all doctors, even non-radiologists, the opportunity for rapid updating.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
计算机断层扫描中静脉注射碘化造影剂的临床药理学、使用和不良反应
造影剂是放射学中用于改善医学图像中进行分析的某些身体结构的可视化的物质。因此,造影剂是诊断药物,因为它们可以增加器官和组织的可见性,并可以识别原本无法观察到的细节。随着多探测器计算机断层扫描的引入,近年来接受对比研究的患者数量呈指数级增长。在计算机断层扫描中,射线图像的形成是通过使用含有碘原子的造影剂来获得的,利用X射线束在穿过解剖区域时呈现的不同衰减。碘化造影剂是一类由复杂分子形成的众多物质,其性质、用途和毒性作用差异很大。本文介绍了计算机断层扫描中使用的静脉碘造影剂的临床药理学、使用和不良反应,为所有医生,甚至非放射科医生提供了快速更新的机会。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Massive localized lymphedema of the thigh: Pseudosarcoma of the morbidly obese Further development of the preceding Gaussian-pencil-beam-model used for calculation of the in-water dose caused by clinical electron-beam irradiation A revised Gaussian pencil beam model for calculation of the in-water dose caused by clinical electron-beam irradiation Fast magnetic resonance arthrography of the labrum Analytic continuation and incomplete data tomography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1