Computerized occlusal analysis of two different removable retainers used during retention phase- A Randomized controlled trial

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Orthodontic Waves Pub Date : 2021-07-03 DOI:10.1080/13440241.2021.1942611
P. B, R. Jain, Purva Verma, Akriti Tiwari, S. Shankar
{"title":"Computerized occlusal analysis of two different removable retainers used during retention phase- A Randomized controlled trial","authors":"P. B, R. Jain, Purva Verma, Akriti Tiwari, S. Shankar","doi":"10.1080/13440241.2021.1942611","DOIUrl":null,"url":null,"abstract":"ABSTRACT Aim: To evaluate and compare occlusal contact force distribution, occlusion time and disclusion time following wear of Begg’s wrap around retainer and Vacuum formed retainer after completion of orthodontic treatment using a T-scan III. Materials and Methods: Twenty subjects after completion of active orthodontic treatment were randomly allocated into two groups, Group I – Begg’s wrap-around retainer (n-10) and Group II–vacuum formed retainer (n-10) one patient was lost to follow up in each group and the final sample size assessed at T1 in each group was 9. T-scan III was used at two-time intervals, T0 – first scan taken immediately after debonding and T1 – taken during retention any time between 10 and 12 months. Comparison of parameters within the groups was done using paired t-test and comparison between the groups was done using independent t-test. Results: No statistically significant difference in the distribution of occlusal contact forces was noted in both groups at T0 and T1 (p value<0.05). Disclusion time reduced in both groups at T1 but a statistically significant reduction in the disclusion time of left lateral excursive movement and protrusive movements (p value<0.05) was noted (T0-T1) in Group I. Statistically significant increase in the occlusion time was noted in Group II (T0-T1) at T1 between the two groups. Conclusion: No differences in occlusal contact force distribution was noted within and between the two groups. Disclusion time reduced in subjects on Begg’s wrap around retainers indicating favourable muscle activity and Occlusion time increased in subjects on vacuum formed retainers.","PeriodicalId":43169,"journal":{"name":"Orthodontic Waves","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2021-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/13440241.2021.1942611","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthodontic Waves","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/13440241.2021.1942611","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

ABSTRACT Aim: To evaluate and compare occlusal contact force distribution, occlusion time and disclusion time following wear of Begg’s wrap around retainer and Vacuum formed retainer after completion of orthodontic treatment using a T-scan III. Materials and Methods: Twenty subjects after completion of active orthodontic treatment were randomly allocated into two groups, Group I – Begg’s wrap-around retainer (n-10) and Group II–vacuum formed retainer (n-10) one patient was lost to follow up in each group and the final sample size assessed at T1 in each group was 9. T-scan III was used at two-time intervals, T0 – first scan taken immediately after debonding and T1 – taken during retention any time between 10 and 12 months. Comparison of parameters within the groups was done using paired t-test and comparison between the groups was done using independent t-test. Results: No statistically significant difference in the distribution of occlusal contact forces was noted in both groups at T0 and T1 (p value<0.05). Disclusion time reduced in both groups at T1 but a statistically significant reduction in the disclusion time of left lateral excursive movement and protrusive movements (p value<0.05) was noted (T0-T1) in Group I. Statistically significant increase in the occlusion time was noted in Group II (T0-T1) at T1 between the two groups. Conclusion: No differences in occlusal contact force distribution was noted within and between the two groups. Disclusion time reduced in subjects on Begg’s wrap around retainers indicating favourable muscle activity and Occlusion time increased in subjects on vacuum formed retainers.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在固位阶段使用的两种不同的可移动固位器的计算机咬合分析-一项随机对照试验
目的:应用T-scan III评价和比较正畸治疗完成后贝格氏包裹固位器和真空成形固位器佩戴后的咬合接触力分布、咬合时间和离断时间。材料与方法:20例患者在完成积极正畸治疗后,随机分为两组,第一组-贝格氏缠绕固位器(n-10)和第二组-真空成形固位器(n-10),每组少随访1例,每组T1时最终样本量为9例。t -扫描III每隔两个时间间隔使用,T0 -在剥离后立即进行第一次扫描,T1 -在保留期间进行10至12个月的任何时间。组内参数比较采用配对t检验,组间比较采用独立t检验。结果:T0、T1时两组牙合接触力分布差异无统计学意义(p值<0.05)。两组在T1时的咬合时间均有所减少,但ⅰ组在T1时左侧游离运动和前突运动的咬合时间减少有统计学意义(p值<0.05)(T0-T1),ⅱ组在T1时咬合时间增加有统计学意义(T0-T1)。结论:两组间牙合接触力分布无明显差异。使用贝格氏固定器的受试者解除时间缩短,表明有利于肌肉活动,而使用真空成形固定器的受试者解除时间增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Orthodontic Waves
Orthodontic Waves DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.40
自引率
0.00%
发文量
0
期刊介绍: Orthodontic Waves is the official publication of the Japanese Orthodontic Society. The aim of this journal is to foster the advancement of orthodontic research and practice. The journal seeks to publish original articles (i) definitive reports of wide interest to the orthodontic community, (ii) Case Reports and (iii) Short Communications. Research papers stand on the scientific basis of orthodontics. Clinical topics covered include all techniques and approaches to treatment planning. All submissions are subject to peer review.
期刊最新文献
Condylectomy as a treatment approach to condylar hyperplasia Effectiveness of a fluoride-releasing orthodontic primer in reducing demineralization around brackets – a systematic review Updates on periodontally accelerated osteogenic orthodontics Incidence of impacted teeth requiring fenestration, traction, and orthodontic treatment in Japan Bond strength of orthodontic buttons on clear aligner materials
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1