Comparison of Calcified Plaque Volume in Coronary Arteries using Filtered Back Projection and Intelli IP Advanced at CT-scan 128 Slice

Q4 Agricultural and Biological Sciences International Journal Bioautomation Pub Date : 2023-03-01 DOI:10.7546/ijba.2023.27.1.000878
Naufal Arya Pratama, L. Muqmiroh, Amillia Kartika Sari, Widiana Ferriastuti, Falentina Syivasari, Muhaimin, Sidarta Prassetyo, Cong Tien Nguyen, Phan Anh Phuong, V. Luu
{"title":"Comparison of Calcified Plaque Volume in Coronary Arteries using Filtered Back Projection and Intelli IP Advanced at CT-scan 128 Slice","authors":"Naufal Arya Pratama, L. Muqmiroh, Amillia Kartika Sari, Widiana Ferriastuti, Falentina Syivasari, Muhaimin, Sidarta Prassetyo, Cong Tien Nguyen, Phan Anh Phuong, V. Luu","doi":"10.7546/ijba.2023.27.1.000878","DOIUrl":null,"url":null,"abstract":"Calcified plaque has a major effect on increasing plaque volume which can increase the risk of Coronary Artery Disease (CAD). The use of Filtered Back Projection (FBP) on CT-scans still has flaws in terms of image quality that can result in errors in the calculation of plaque volume. Intelli IP Advanced is hitachi CT-scan’s Iterative Reconstruction (IR) type and can improve image quality compared to FBP. The purpose of this study is to find out the comparison of calcified plaque volume in coronary arteries using FBP and Intelli IP Advanced. This study used 38 samples of coronary artery blood vessels that had calcified plaque and reconstructed using the reconstruction of FBP and Intelli IP Advanced algorithms (Levels 1-3). Plaque calculation is done automatically using aquarius intuition edition application on CT-scan Hitachi SCENARIA 128 Slice. The results in this study found significant differences (p < 0.05) in calcified plaque volume results with the use of FBP and Intelli IP Advanced algorithm reconstruction (Levels 1-3). However, significant differences are found only in algorithm reconstruction pairs (Intelli IP Advanced Level 1 and Level 3) that have a p < 0.05. The conclusion is that IR affects the volume value of calcified plaque.","PeriodicalId":38867,"journal":{"name":"International Journal Bioautomation","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal Bioautomation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7546/ijba.2023.27.1.000878","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
引用次数: 0

Abstract

Calcified plaque has a major effect on increasing plaque volume which can increase the risk of Coronary Artery Disease (CAD). The use of Filtered Back Projection (FBP) on CT-scans still has flaws in terms of image quality that can result in errors in the calculation of plaque volume. Intelli IP Advanced is hitachi CT-scan’s Iterative Reconstruction (IR) type and can improve image quality compared to FBP. The purpose of this study is to find out the comparison of calcified plaque volume in coronary arteries using FBP and Intelli IP Advanced. This study used 38 samples of coronary artery blood vessels that had calcified plaque and reconstructed using the reconstruction of FBP and Intelli IP Advanced algorithms (Levels 1-3). Plaque calculation is done automatically using aquarius intuition edition application on CT-scan Hitachi SCENARIA 128 Slice. The results in this study found significant differences (p < 0.05) in calcified plaque volume results with the use of FBP and Intelli IP Advanced algorithm reconstruction (Levels 1-3). However, significant differences are found only in algorithm reconstruction pairs (Intelli IP Advanced Level 1 and Level 3) that have a p < 0.05. The conclusion is that IR affects the volume value of calcified plaque.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
冠状动脉钙化斑块体积的筛选后投影与Intelli IP - Advanced在128层ct扫描中的比较
钙化斑块的主要作用是增加斑块体积,从而增加冠状动脉疾病(CAD)的风险。在ct扫描中使用滤波后投影(FBP)在图像质量方面仍然存在缺陷,可能导致斑块体积计算错误。Intelli IP Advanced是日立ct扫描的迭代重建(IR)类型,与FBP相比,可以改善图像质量。本研究的目的是比较FBP和Intelli IP Advanced对冠状动脉钙化斑块体积的影响。本研究使用38例钙化斑块的冠状动脉血管样本,并使用FBP重建和Intelli IP高级算法(level 1-3)进行重建。斑块计算是自动使用宝瓶直觉版应用程序在ct扫描日立SCENARIA 128切片。本研究结果发现,FBP与Intelli IP Advanced算法重建在钙化斑块体积结果上存在显著差异(p < 0.05) (level 1-3)。然而,只有在算法重构对(Intelli IP Advanced Level 1和Level 3)中发现显著差异,p < 0.05。结论:IR影响钙化斑块的体积值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal Bioautomation
International Journal Bioautomation Agricultural and Biological Sciences-Food Science
CiteScore
1.10
自引率
0.00%
发文量
22
审稿时长
12 weeks
期刊最新文献
Differential Effect of Novel Plant Cystatins on the Adhesive Behaviour of Normal and Cancer Breast Cells Genome Wide Identification, Characterization and Evolutionary Analysis of T6SS in Burkholderia cenocepacia Strains Dynamic Model Inference of Gene Regulatory Network based on Hybrid Parallel Genetic Algorithm and Threshold Qualification Method Effect of Graphene Oxide and Ammonia-modified Graphene Oxide Particles on ATPase Activity of Rat Liver Mitochondria The Ecological Role of Probiotics in in vitro Culture for the Improvement of Health in the Poultry Industry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1