James P Cline, Marcus H Mendenhall, Joseph J Ritter, David Black, Albert Henins, John E Bonevich, Pamela S Whitfield, James J Filliben
{"title":"The Certification of Standard Reference Material 1979: Powder Diffraction Line Profile Standard for Crystallite Size Analysis.","authors":"James P Cline, Marcus H Mendenhall, Joseph J Ritter, David Black, Albert Henins, John E Bonevich, Pamela S Whitfield, James J Filliben","doi":"10.6028/jres.125.020","DOIUrl":null,"url":null,"abstract":"<p><p>This rather long-standing project has resulted in a National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) for the analysis of crystallite size from a consideration of powder diffraction line profile broadening. It consists of two zinc oxide powders, one with a crystallite size distribution centered at approximately 15 nm, and a second centered at about 60 nm. These materials display the effects of stacking faults that broaden specific <i>hkl</i> reflections and a slight amount of microstrain broadening. Certification data were collected on the high-resolution powder diffractometer located at beamline 11-BM of the Advanced Photon Source, and on a NIST-built laboratory diffractometer equipped with a Johansson incident beam monochromator and position sensitive detector. Fourier transforms were extracted from the raw data using a modified, two-step profile fitting procedure that addressed the issue of accurate background determination. The mean column lengths, 〈<i>L</i>〉<sub>area</sub> and 〈<i>L</i>〉<sub>vol</sub>, were then computed from the Fourier transforms of the specimen contribution for each reflection. Data were also analyzed with fundamental parameters approach refinements using broadening models to yield 〈<i>L</i>〉<sub>area</sub> and 〈<i>L</i>〉<sub>vol</sub> values. These values were consistent with the model-independent Fourier transform results; however, small discrepancies were noted for the 〈<i>L</i>〉<sub>area</sub> values from both machines and both crystallite size ranges. The fundamental parameters approach fits to the laboratory data yielded the certified lattice parameters.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":" ","pages":"125020"},"PeriodicalIF":17.7000,"publicationDate":"2020-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11239193/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.6028/jres.125.020","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
This rather long-standing project has resulted in a National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) for the analysis of crystallite size from a consideration of powder diffraction line profile broadening. It consists of two zinc oxide powders, one with a crystallite size distribution centered at approximately 15 nm, and a second centered at about 60 nm. These materials display the effects of stacking faults that broaden specific hkl reflections and a slight amount of microstrain broadening. Certification data were collected on the high-resolution powder diffractometer located at beamline 11-BM of the Advanced Photon Source, and on a NIST-built laboratory diffractometer equipped with a Johansson incident beam monochromator and position sensitive detector. Fourier transforms were extracted from the raw data using a modified, two-step profile fitting procedure that addressed the issue of accurate background determination. The mean column lengths, 〈L〉area and 〈L〉vol, were then computed from the Fourier transforms of the specimen contribution for each reflection. Data were also analyzed with fundamental parameters approach refinements using broadening models to yield 〈L〉area and 〈L〉vol values. These values were consistent with the model-independent Fourier transform results; however, small discrepancies were noted for the 〈L〉area values from both machines and both crystallite size ranges. The fundamental parameters approach fits to the laboratory data yielded the certified lattice parameters.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.