EXPERIMENTAL INVESTIGATION AND CFD SIMULATION OF INDOOR AIR QUALITY IN ROOM USING IMPINGING JET VENTILATION SYSTEM AT DIFFERENT OCCUPANT DISTRIBUTION

Ala'a Abbas Mahdi, S. Mohammed Abbas
{"title":"EXPERIMENTAL INVESTIGATION AND CFD SIMULATION OF INDOOR AIR QUALITY IN ROOM USING IMPINGING JET VENTILATION SYSTEM AT DIFFERENT OCCUPANT DISTRIBUTION","authors":"Ala'a Abbas Mahdi, S. Mohammed Abbas","doi":"10.32852/iqjfmme.v21i2.548","DOIUrl":null,"url":null,"abstract":"The current paper reports the analysis and design of air quality and human thermal comfort in rooms using impinging jet ventilation system at different occupant distribution. Theoretical and experimental studies at different situations of occupant distribution used the square cross sectional supply air duct with height from the foot level end (0.1h). This work presents a numerical study for predicting the indoor airflow and temperature distribution by adopting impinging jet ventilation system in office room. The emergence of the three zones flow field of an impinging jet is mostly divided into three distinguished zones: impingement zone, wall jet zone and free jet zone which produce excessive kinetic energy at the stagnation zone and distribute approximately in the longitudinal and lateral directions over the floor. Acceptable Air Distribution Performance Index (ADPI), effective temperature and ventilation efficiency were found at situations of occupant distribution (when the occupant located at the center of the room one sitting in front of the other gives optimum human thermal comfort if compared with the other situations of occupant distributions).","PeriodicalId":31812,"journal":{"name":"Iraqi Journal for Mechanical and Materials Engineering","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iraqi Journal for Mechanical and Materials Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32852/iqjfmme.v21i2.548","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The current paper reports the analysis and design of air quality and human thermal comfort in rooms using impinging jet ventilation system at different occupant distribution. Theoretical and experimental studies at different situations of occupant distribution used the square cross sectional supply air duct with height from the foot level end (0.1h). This work presents a numerical study for predicting the indoor airflow and temperature distribution by adopting impinging jet ventilation system in office room. The emergence of the three zones flow field of an impinging jet is mostly divided into three distinguished zones: impingement zone, wall jet zone and free jet zone which produce excessive kinetic energy at the stagnation zone and distribute approximately in the longitudinal and lateral directions over the floor. Acceptable Air Distribution Performance Index (ADPI), effective temperature and ventilation efficiency were found at situations of occupant distribution (when the occupant located at the center of the room one sitting in front of the other gives optimum human thermal comfort if compared with the other situations of occupant distributions).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
撞击射流通风系统在不同人员分布下室内空气质量的实验研究及CFD模拟
本文对不同人员分布下的冲击射流通风系统室内空气质量和人体热舒适性进行了分析与设计。理论和实验研究在不同情况下的人员分布使用方形截面送风风管,高度从脚水平端(0.1h)。本文对办公楼采用冲击射流通风系统预测室内气流和温度分布进行了数值研究。三区冲击射流流场的出现主要分为三个明显的区域:冲击区、壁面射流区和自由射流区,它们在滞止区产生过多的动能,在底板上大致沿纵向和横向分布。可接受气流分布性能指数(ADPI)、有效温度和通风效率在不同的人员分布情况下(当人员位于房间中心时,与其他人员分布情况相比,一个人坐在另一个人的前面时,人体热舒适最佳)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
11
审稿时长
24 weeks
期刊最新文献
INVESTIGATION OF VARIABLES GEOMETRY OF NOVEL PIN CORE-SANDWICH STRUCTURE ON UNSATURATED POLYESTER FLEXTURAL PROPERTIES EXPERIMENTAL AND NUMERICAL ANALYSIS OF NEW CURVED CONFIGURATION OF HEAT SINKS REVIEW OF THE EFFECT OF OCCUPIED DENSITY WITH MIXING VENTILATION ON THERMAL HUMAN COMFORT AND INDOOR AIR QUALITY STUDY ОF PRESSURE DROP AND HEАT TRANSFER CHARACTERISTICS ОF MINI-CHANNEL HEАT SINKS EFFECT OF GEOMETRICAL AND OPERATIONAL PARAMETER ON OIL-WATER SEPARATION IN AXIAL INLET HYDROCYCLONE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1