Calculation of specific electrical loads of residential buildings based on actual measurements

A. Akhmetshin, Y. I. Soluyanov, A. Fedotov, N. Chernova, V. Soluyanov
{"title":"Calculation of specific electrical loads of residential buildings based on actual measurements","authors":"A. Akhmetshin, Y. I. Soluyanov, A. Fedotov, N. Chernova, V. Soluyanov","doi":"10.21443/1560-9278-2022-25-4-313-323","DOIUrl":null,"url":null,"abstract":"Updating the development of specific electrical loads of residential buildings of clusters 1 (up to 5 floors) and 2 (6-11 floors) based on actual measurements (with amendments to the Code of Rules 256.1325800.2016 \"Electrical installations of residential and public buildings. Design and installation rules\") contributes reducing the cost of technological connection in residential construction, as well as reducing the actual unused \"locked power\" at the same time as reducing electricity losses in power transformers. In the course of the study, an analysis has been made of the actual electrical loads of residential buildings in Moscow for the periods from November 1 to November 30, 2021 and from December 25, 2021 to January 31, 2022. The number of the studied sample for cluster 1 is 91 houses, for cluster 2 - 58 houses. When determining the maximum specific power of a sample set of multi-apartment residential buildings in Moscow in clusters 1 and 2, an average value and a confidence interval have been established, which \"covers\" the average of the general population with a probability of 95 %; a comparative analysis of the actual specific electrical loads of a residential building with the loads given in the Code of Rules has been carried out. Based on the results of statistical processing of a sample of multi-apartment buildings in clusters 1 and 2, the dependence of the maximum specific power on the number of apartments in a residential building has been determined with a trend line that clearly illustrates the trend in the studied dependence.","PeriodicalId":30200,"journal":{"name":"Vestnik MGTU","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik MGTU","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21443/1560-9278-2022-25-4-313-323","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Updating the development of specific electrical loads of residential buildings of clusters 1 (up to 5 floors) and 2 (6-11 floors) based on actual measurements (with amendments to the Code of Rules 256.1325800.2016 "Electrical installations of residential and public buildings. Design and installation rules") contributes reducing the cost of technological connection in residential construction, as well as reducing the actual unused "locked power" at the same time as reducing electricity losses in power transformers. In the course of the study, an analysis has been made of the actual electrical loads of residential buildings in Moscow for the periods from November 1 to November 30, 2021 and from December 25, 2021 to January 31, 2022. The number of the studied sample for cluster 1 is 91 houses, for cluster 2 - 58 houses. When determining the maximum specific power of a sample set of multi-apartment residential buildings in Moscow in clusters 1 and 2, an average value and a confidence interval have been established, which "covers" the average of the general population with a probability of 95 %; a comparative analysis of the actual specific electrical loads of a residential building with the loads given in the Code of Rules has been carried out. Based on the results of statistical processing of a sample of multi-apartment buildings in clusters 1 and 2, the dependence of the maximum specific power on the number of apartments in a residential building has been determined with a trend line that clearly illustrates the trend in the studied dependence.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
根据实测计算住宅建筑比电负荷
根据实际测量,更新第1组(最高5层)和第2组(6-11层)住宅建筑物的特定电力负荷发展(修订规则守则256.1325800.2016“住宅和公共建筑物的电气装置”)。设计和安装规则”)有助于降低住宅建设中的技术连接成本,减少实际未使用的“锁定功率”,同时减少电力变压器的电力损耗。在研究过程中,分析了2021年11月1日至11月30日和2021年12月25日至2022年1月31日期间莫斯科住宅建筑的实际电力负荷。聚类1的样本数量为91户,聚类2的样本数量为58户。在确定莫斯科1和2组多公寓住宅建筑样本集的最大比功率时,建立了平均值和置信区间,该平均值“覆盖”了一般人群的平均值,概率为95%;对住宅建筑的实际特定电气负荷与《规则》中规定的负荷进行了比较分析。基于集群1和集群2中多公寓建筑样本的统计处理结果,确定了最大比功率与住宅建筑中公寓数量的依赖关系,并绘制了一条趋势线,清楚地说明了所研究的依赖关系的趋势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
27
审稿时长
5 weeks
期刊最新文献
The effect of spacing grid in the precision solution of the inverse vertical electric sounding problem Investigation of the biopotential of products of hydrolysis of waste from cutting the white-legged shrimp Penaeus vannamei Solving the problem of optimizing fishing activities Development of methodology for creating technologies for processing low-grade semi-finished products of fish oils and fatty waste Development of the technology of milk sauce with the addition of guarana
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1