B. Ivković, Milkica Crevar, Anka Cvetanović, Katarina Ubavkić, B. Marković
{"title":"Development and validation of RP-HPLC method for quantification of trace levels of topical corticosteroids in ambiphilic cream","authors":"B. Ivković, Milkica Crevar, Anka Cvetanović, Katarina Ubavkić, B. Marković","doi":"10.1556/1326.2021.00998","DOIUrl":null,"url":null,"abstract":"\n Corticosteroids are anti-inflammatory and immunosuppressant drugs. Topical corticosteroids formulations (ointments, creams, gels) are used in the treatment of different types of dermatitis and urticaria. Considering their therapeutic and whitening effects, they are frequently used for counterfeiting of cosmetic products. Corticosteroids can cause different local and systemic side effects. HPLC method is often chosen for their analysis, because it is selective, sensitive, precise, simple and fast.\n The aim of this study was optimization and validation of RP-HPLC method with UV detection for determination of trace levels of corticosteroids in ambiphilic creams. This method is used for qualitative and quantitative analysis of evaluated corticosteroids.\n Mometasone furoate, hydrocortisone acetate, fluocinonide, fluocinolone acetonide, betamethasone, betamethasone dipropionate and triamcinolone acetonide were evaluated. Separation was performed on Inertsil® ODS-3V 250 × 4.6 mm, 5 μm chromatographic column. Mobile phase was mixture of acetonitrile and water 50:50 (v/v) with gradient elution and flow rate 1 mL min−1. Column temperature was held on 40 °C and UV detection was performed at 240 nm.\n Selectivity, linearity, accuracy, precision and limit of quantification (LOQ) were evaluated. Method is selective because ambiphilic cream base peaks and corticosteroids peaks were not overlapping. Linearity was confirmed since correlation coefficient was 1 for all compounds. Accuracy and precision were evaluated for hydrocortisone acetate and betamethasone dipropionate. Determined Recovery values were in range of 70–130%. Both RSD values (21.46% and 9.59%) were lower than 30%. Method is highly sensitive since LOQ concentrations were in ng mL−1 range.\n All evaluated parameters of validation were in accordance with regulatory requirements. Validated RP-HPLC method can be used for qualitative and quantitative analysis of selected corticosteroids in ambiphilic creams.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2022-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2021.00998","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Corticosteroids are anti-inflammatory and immunosuppressant drugs. Topical corticosteroids formulations (ointments, creams, gels) are used in the treatment of different types of dermatitis and urticaria. Considering their therapeutic and whitening effects, they are frequently used for counterfeiting of cosmetic products. Corticosteroids can cause different local and systemic side effects. HPLC method is often chosen for their analysis, because it is selective, sensitive, precise, simple and fast.
The aim of this study was optimization and validation of RP-HPLC method with UV detection for determination of trace levels of corticosteroids in ambiphilic creams. This method is used for qualitative and quantitative analysis of evaluated corticosteroids.
Mometasone furoate, hydrocortisone acetate, fluocinonide, fluocinolone acetonide, betamethasone, betamethasone dipropionate and triamcinolone acetonide were evaluated. Separation was performed on Inertsil® ODS-3V 250 × 4.6 mm, 5 μm chromatographic column. Mobile phase was mixture of acetonitrile and water 50:50 (v/v) with gradient elution and flow rate 1 mL min−1. Column temperature was held on 40 °C and UV detection was performed at 240 nm.
Selectivity, linearity, accuracy, precision and limit of quantification (LOQ) were evaluated. Method is selective because ambiphilic cream base peaks and corticosteroids peaks were not overlapping. Linearity was confirmed since correlation coefficient was 1 for all compounds. Accuracy and precision were evaluated for hydrocortisone acetate and betamethasone dipropionate. Determined Recovery values were in range of 70–130%. Both RSD values (21.46% and 9.59%) were lower than 30%. Method is highly sensitive since LOQ concentrations were in ng mL−1 range.
All evaluated parameters of validation were in accordance with regulatory requirements. Validated RP-HPLC method can be used for qualitative and quantitative analysis of selected corticosteroids in ambiphilic creams.
皮质类固醇是抗炎和免疫抑制药物。局部皮质类固醇制剂(软膏、乳膏、凝胶)用于治疗不同类型的皮炎和荨麻疹。考虑到它们的治疗和美白效果,它们经常被用于假冒化妆品。皮质类固醇可引起不同的局部和全身副作用。高效液相色谱法具有选择性好、灵敏度高、精密度高、简便、快速等优点。本研究的目的是优化和验证反相高效液相色谱-紫外检测法测定两亲性面霜中微量皮质激素的含量。该方法可用于评价的皮质类固醇的定性和定量分析。评价糠酸莫米松、醋酸氢化可的松、氟西尼德、醋酸氟西诺酮、倍他米松、二丙酸倍他米松和曲安奈德。色谱柱为Inertsil®ODS-3V 250 × 4.6 mm, 5 μm。流动相为乙腈与水的混合物50:50 (v/v),梯度洗脱,流速1 mL min - 1。柱温保持在40℃,紫外检测波长240 nm。对该方法的选择性、线性、准确度、精密度和定量限进行了评价。方法是选择性的,因为两亲性乳膏底峰和皮质激素峰不重叠。所有化合物的相关系数均为1,证实了线性关系。评价醋酸氢化可的松和二丙酸倍他米松的准确度和精密度。测定的回收率范围为70-130%。RSD值分别为21.46%和9.59%,均小于30%。LOQ浓度在ng mL−1范围内,灵敏度高。所有评价的验证参数均符合法规要求。经验证的反相高效液相色谱法可用于两亲性乳膏中所选皮质激素的定性和定量分析。
期刊介绍:
Acta Chromatographica
Open Access
Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.