Jennifer W H Shum, Bonnie N. K. Choy, J. Chan, W. L. Ho, Stephanie Cheri Woo, J. Lai
{"title":"EX-PRESS shunt implantation in Chinese glaucoma patients: 1-year results","authors":"Jennifer W H Shum, Bonnie N. K. Choy, J. Chan, W. L. Ho, Stephanie Cheri Woo, J. Lai","doi":"10.12809/HKJO-V23N1-231","DOIUrl":null,"url":null,"abstract":"Aim: To report the safety and efficacy of EX-PRESS glaucoma filtration device implantation in Chinese glaucoma patients.Methods: Records of 38 eyes from 38 Chinese glaucoma patients who underwent EX-PRESS shunt implantation between August 2012 and June 2014 with at least 1 year of follow-up were retrospectively reviewed. Main outcome measures included intraocular pressure (IOP), visual acuity, success rate, number of topical antiglaucoma medications applied, and postoperative complications.Results: The mean IOP reduced significantly from 25.8±12.4 mmHg before surgery to 15.1±6.3 mmHg at 1 year after surgery (p<0.005). Repeated measures ANOVA showed that IOP at all time points after surgery was significantly lower than IOP before surgery. 73.7% of patients achieved complete or qualified success.Conclusions: EX-PRESS shunt implantation is safe and effective in Chinese patients.","PeriodicalId":90844,"journal":{"name":"Hong Kong journal of ophthalmology : the official publication of the College of Ophthalmologists of Hong Kong = Xianggang yan ke xue kan : Xianggang yan ke yi xue yuan","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hong Kong journal of ophthalmology : the official publication of the College of Ophthalmologists of Hong Kong = Xianggang yan ke xue kan : Xianggang yan ke yi xue yuan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12809/HKJO-V23N1-231","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Aim: To report the safety and efficacy of EX-PRESS glaucoma filtration device implantation in Chinese glaucoma patients.Methods: Records of 38 eyes from 38 Chinese glaucoma patients who underwent EX-PRESS shunt implantation between August 2012 and June 2014 with at least 1 year of follow-up were retrospectively reviewed. Main outcome measures included intraocular pressure (IOP), visual acuity, success rate, number of topical antiglaucoma medications applied, and postoperative complications.Results: The mean IOP reduced significantly from 25.8±12.4 mmHg before surgery to 15.1±6.3 mmHg at 1 year after surgery (p<0.005). Repeated measures ANOVA showed that IOP at all time points after surgery was significantly lower than IOP before surgery. 73.7% of patients achieved complete or qualified success.Conclusions: EX-PRESS shunt implantation is safe and effective in Chinese patients.