Structural Pounding Effect on the Seismic Performance of a Multistorey Reinforced Concrete Frame Structure

IF 2.7 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Infrastructures Pub Date : 2023-08-02 DOI:10.3390/infrastructures8080122
Kosmas E. Bantilas, M. C. Naoum, Ioannis E. Kavvadias, C. Karayannis, A. Elenas
{"title":"Structural Pounding Effect on the Seismic Performance of a Multistorey Reinforced Concrete Frame Structure","authors":"Kosmas E. Bantilas, M. C. Naoum, Ioannis E. Kavvadias, C. Karayannis, A. Elenas","doi":"10.3390/infrastructures8080122","DOIUrl":null,"url":null,"abstract":"During intense ground motion excitations, the pounding between adjacent buildings may result in extensive structural damage. Despite the provision of regulations regarding the minimum separation gap required to prevent structural collisions, the majority of existing structures are poorly separated. The modern seismic design and assessment of structures are based on the definition of acceptable response levels in relation to the intensity of seismic action, which is usually determined by an acceptable probability of exceedance. From this point of view, the seismic performance of a typical eight-storey reinforced concrete (RC) frame structure is evaluated in terms of pounding. In particular, the performance is evaluated using six different separation gap distances as a fraction of the EC8 minimum distance. As the height of the adjacent structure affected the required separation distance, the examined RC structure was assumed to interact with four idealized rigid structures of one to four storeys. The typical storey height was equal between the examined structures; therefore, collision could occur at the diaphragm level. To this end, incidental dynamic analyses (IDAs) were performed, and the fragility curves for different limit states were obtained for each case. Finally, the seismic fragility was combined with the hazard data to evaluate the seismic performance probabilistically.","PeriodicalId":13601,"journal":{"name":"Infrastructures","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2023-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infrastructures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/infrastructures8080122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

During intense ground motion excitations, the pounding between adjacent buildings may result in extensive structural damage. Despite the provision of regulations regarding the minimum separation gap required to prevent structural collisions, the majority of existing structures are poorly separated. The modern seismic design and assessment of structures are based on the definition of acceptable response levels in relation to the intensity of seismic action, which is usually determined by an acceptable probability of exceedance. From this point of view, the seismic performance of a typical eight-storey reinforced concrete (RC) frame structure is evaluated in terms of pounding. In particular, the performance is evaluated using six different separation gap distances as a fraction of the EC8 minimum distance. As the height of the adjacent structure affected the required separation distance, the examined RC structure was assumed to interact with four idealized rigid structures of one to four storeys. The typical storey height was equal between the examined structures; therefore, collision could occur at the diaphragm level. To this end, incidental dynamic analyses (IDAs) were performed, and the fragility curves for different limit states were obtained for each case. Finally, the seismic fragility was combined with the hazard data to evaluate the seismic performance probabilistically.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
结构冲击对多层钢筋混凝土框架结构抗震性能的影响
在强烈的地震动激励下,相邻建筑物之间的碰撞可能导致大范围的结构损伤。尽管规定了防止结构碰撞所需的最小分离间隙,但大多数现有结构的分离效果不佳。现代结构的抗震设计和评估基于与地震作用强度相关的可接受响应水平的定义,地震作用强度通常由可接受的超越概率决定。从这个角度出发,对一个典型的八层钢筋混凝土框架结构的抗震性能进行了冲击评估。特别地,使用六个不同的分离间隙距离作为EC8最小距离的一部分来评估性能。由于相邻结构的高度会影响所需的分离距离,因此假设所检查的RC结构与四个理想化的一到四层刚性结构相互作用。受检结构之间的典型层高相等;因此,碰撞可能发生在振膜水平。为此,进行了偶然动力分析(IDA),并获得了每种情况下不同极限状态的脆性曲线。最后,将地震易损性与危险性数据相结合,对其抗震性能进行概率评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Infrastructures
Infrastructures Engineering-Building and Construction
CiteScore
5.20
自引率
7.70%
发文量
145
审稿时长
11 weeks
期刊最新文献
Exploring the Cyclic Behaviour of URM Walls with and without Damp-Proof Course (DPC) Membranes through Discrete Element Method Modeling Variability in Seismic Analysis of Concrete Gravity Dams: A Parametric Analysis of Koyna and Pine Flat Dams Smartphone-Based Cost-Effective Pavement Performance Model Development Using a Machine Learning Technique with Limited Data State of the Art Review of Ageing of Bituminous Binders and Asphalt Mixtures: Ageing Simulation Techniques, Ageing Inhibitors and the Relationship between Simulated Ageing and Field Ageing On the Generation of Digital Data and Models from Point Clouds: Application to a Pedestrian Bridge Structure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1