Clinical effects of the implantation of porous tantalum rod under three-dimensional C-arm positioning in treating ARCO I-II non-traumatic necrosis of the femoral head

Rui Luo, Guomin Li, B. Liu, Bo Li, X. Tian, Hu Ruyin
{"title":"Clinical effects of the implantation of porous tantalum rod under three-dimensional C-arm positioning in treating ARCO I-II non-traumatic necrosis of the femoral head","authors":"Rui Luo, Guomin Li, B. Liu, Bo Li, X. Tian, Hu Ruyin","doi":"10.3760/CMA.J.ISSN.0253-2352.2019.23.004","DOIUrl":null,"url":null,"abstract":"Objective \nTo evaluate the clinical effects of the implantation of porous tantalum rod under three-dimensional (3D) C-arm positioning in the treatment of ARCO I and II non-traumatic femoral head necrosis. \n \n \nMethods \nFifty patients (58 hips, 39 males and 11 females, mean age 33.52 years) with non-traumatic femoral head in ARCO I-II were included from January 2009 to December 2011. All patients received implantation of porous tantalum rod. The 3D C-arm X-ray positioning was used in 24 patients (29 hips), while traditional C-arm X-ray positioning was performed in the other patients. The visual analogue scale (VAS), Harris score and superior rate were evaluated at 0.5, 1, 2, and 4 years after the surgery. Total hip arthroplasty was regarded as the end event for survival rate. \n \n \nResults \nIn the 3D C-arm X-ray positioning group, the VAS score decreased from 7.17±1.00 points preoperatively to 2.38±0.86 points at half year, to 2.10±1.40 points at 1 year, to 2.38±1.66 points at 2 years, and to 2.21±1.47 points at 4 years postoperatively (F=98.78, P=0.00). Meanwhile, the Harris score increased significantly from 73.97±3.49 points preoperatively to 89.90±1.93, 89.93±3.26, 89.21±5.83, 88.57±5.70 points at the follow up, respectively (F=84.35, P=0.00). According to the analysis of the pre-operative and post-operative image data, there was no significant difference in progress in the ARCO staging at 23 hips duration the follow-up. Four hips were developed to ARCO III and two hips to ARCO II. Thus, the success rate of operation was 79% (23/29). There were two hips underwent total hip arthroplasty, so the survival rate of femoral head was 93% (27/29). The trend of VAS score and Harris score in the C-arm X-ray positioning group was in accordance with the 3D C-arm X-ray positioning group but without statistically significant difference (P>0.05). The operation duration 31.38±3.96 min, blood loss 36.72±5.59 ml, the ratio of distance of metal rod to bone cortex in femoral neck 0.48±0.10, and the distance of mental rod to center of necrosis 0.18±0.07 cm in 3D C-arm X-ray positioning group was superior to C-arm X-ray positioning group (respectively 41.97±4.64 min, 41.49±4.46 ml, 0.46±0.06, 0.23±0.10 cm, P<0.05). \n \n \nConclusion \nThe implantation of tantalum rod in treating ARCO I-II non-traumatic femoral head necrosis can increase the function of hip joint, relieve the symptoms of necrosis of femoral head, alleviate the progress of femoral head necrosis in X-ray, and obtain a higher survival rate. The 3D C-arm positioning in surgical operation could improve the accuracy and safety of surgery. \n \n \nKey words: \nFemur head necrosis; Tantalum; Imaging, three-dimensional; X-rays; Radiography","PeriodicalId":36405,"journal":{"name":"中华骨科杂志","volume":"39 1","pages":"1440-1446"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华骨科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.0253-2352.2019.23.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective To evaluate the clinical effects of the implantation of porous tantalum rod under three-dimensional (3D) C-arm positioning in the treatment of ARCO I and II non-traumatic femoral head necrosis. Methods Fifty patients (58 hips, 39 males and 11 females, mean age 33.52 years) with non-traumatic femoral head in ARCO I-II were included from January 2009 to December 2011. All patients received implantation of porous tantalum rod. The 3D C-arm X-ray positioning was used in 24 patients (29 hips), while traditional C-arm X-ray positioning was performed in the other patients. The visual analogue scale (VAS), Harris score and superior rate were evaluated at 0.5, 1, 2, and 4 years after the surgery. Total hip arthroplasty was regarded as the end event for survival rate. Results In the 3D C-arm X-ray positioning group, the VAS score decreased from 7.17±1.00 points preoperatively to 2.38±0.86 points at half year, to 2.10±1.40 points at 1 year, to 2.38±1.66 points at 2 years, and to 2.21±1.47 points at 4 years postoperatively (F=98.78, P=0.00). Meanwhile, the Harris score increased significantly from 73.97±3.49 points preoperatively to 89.90±1.93, 89.93±3.26, 89.21±5.83, 88.57±5.70 points at the follow up, respectively (F=84.35, P=0.00). According to the analysis of the pre-operative and post-operative image data, there was no significant difference in progress in the ARCO staging at 23 hips duration the follow-up. Four hips were developed to ARCO III and two hips to ARCO II. Thus, the success rate of operation was 79% (23/29). There were two hips underwent total hip arthroplasty, so the survival rate of femoral head was 93% (27/29). The trend of VAS score and Harris score in the C-arm X-ray positioning group was in accordance with the 3D C-arm X-ray positioning group but without statistically significant difference (P>0.05). The operation duration 31.38±3.96 min, blood loss 36.72±5.59 ml, the ratio of distance of metal rod to bone cortex in femoral neck 0.48±0.10, and the distance of mental rod to center of necrosis 0.18±0.07 cm in 3D C-arm X-ray positioning group was superior to C-arm X-ray positioning group (respectively 41.97±4.64 min, 41.49±4.46 ml, 0.46±0.06, 0.23±0.10 cm, P<0.05). Conclusion The implantation of tantalum rod in treating ARCO I-II non-traumatic femoral head necrosis can increase the function of hip joint, relieve the symptoms of necrosis of femoral head, alleviate the progress of femoral head necrosis in X-ray, and obtain a higher survival rate. The 3D C-arm positioning in surgical operation could improve the accuracy and safety of surgery. Key words: Femur head necrosis; Tantalum; Imaging, three-dimensional; X-rays; Radiography
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三维c臂定位下多孔钽棒植入术治疗ARCO I-II型非外伤性股骨头坏死的临床效果
目的探讨三维(3D) c臂定位下多孔钽棒植入术治疗ARCO型和II型非外伤性股骨头坏死的临床效果。方法2009年1月至2011年12月对50例非外伤性股骨头患者(58髋,男39例,女11例)进行回顾性分析,平均年龄33.52岁。所有患者均行多孔钽棒植入术。24例患者(29髋)采用三维c臂x线定位,其余患者采用传统c臂x线定位。分别于术后0.5年、1年、2年、4年评估视觉模拟评分(VAS)、Harris评分及优胜率。全髋关节置换术被认为是生存率的终点事件。结果三维c臂x线定位组VAS评分由术前7.17±1.00分降至半年2.38±0.86分,1年2.10±1.40分,2年2.38±1.66分,4年2.21±1.47分(F=98.78, P=0.00)。Harris评分由术前的73.97±3.49分上升至随访时的89.90±1.93分、89.93±3.26分、89.21±5.83分、88.57±5.70分(F=84.35, P=0.00)。根据术前和术后影像资料分析,随访期间23髋的ARCO分期进展无显著差异。四个髋关节发展到ARCO III,两个髋关节发展到ARCO II。手术成功率为79%(23/29)。2髋行全髋关节置换术,股骨头成活率93%(27/29)。c臂x线体位组VAS评分和Harris评分趋势与3D c臂x线体位组一致,但差异无统计学意义(P < 0.05)。三维c臂x线定位组手术时间31.38±3.96 min,出血量36.72±5.59 ml,股骨颈金属棒距骨皮质距离0.48±0.10,金属棒距坏死中心距离0.18±0.07 cm(分别为41.97±4.64 min, 41.49±4.46 ml, 0.46±0.06,0.23±0.10 cm, P<0.05)优于c臂x线定位组。结论钽棒植入术治疗ARCO I-II型非外伤性股骨头坏死可增加髋关节功能,缓解股骨头坏死症状,缓解x线股骨头坏死进展,获得较高生存率。三维c型臂在手术中的定位可以提高手术的准确性和安全性。关键词:股骨头坏死;钽;三维成像;x射线;射线照相法
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中华骨科杂志
中华骨科杂志 Medicine-Surgery
CiteScore
0.80
自引率
0.00%
发文量
8153
期刊介绍:
期刊最新文献
A comparative study of the efficacy and complications of oblique lumbar interbody fusion and transforaminal lumbar interbody fusion in lumbar degenerative scoliosis A comparative study on the treatment of degenerative lumbar spondylolisthesis by oblique interbody fusion and minimally invasive transforminal lumbar interbody fusion Rooting, and growing with luxuriant branches and leaves-the story of oblique lateral interbody fusion in China Percutaneous endoscopic lumbar discectomy combined with oblique lateral interbody fusion for degenerative lumbar diseases with ruptured disc herniation The complications of oblique lateral interbody fusion procedure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1