{"title":"Low-frequency elastic plateau in linear viscoelasticity of polyelectrolyte coacervates","authors":"Huiling Li, Y. Liu, A. Shetty, R. Larson","doi":"10.1122/8.0000488","DOIUrl":null,"url":null,"abstract":"A thorough study is made of the dependences on salt concentration and polymer chain lengths of the low-frequency plateau of coacervates of poly (diallyl dimethyl ammonium chloride), PDADMAC, and poly (sodium 4-styrenesulfonate), PSS. The reliability and reproducibility of these measurements are carefully checked by determining the frequency-dependent stress limits of the rheometer through the use of reference fluids and by repeat experiments with coacervates. Long-time frequency sweeps show that coacervates with less salt are more repeatable than those with higher salt. A low-frequency plateau reliably appears only below a critical salt concentration, and the magnitude of the plateau depends strongly on salt concentration and chain lengths of both polycation and polyanion. It is only present for the molecular weight of the polycation, PDADMAC, higher than 100 kDa, but the magnitude of the plateau is more strongly influenced by the chain length of the polyanion, PSS. Possible causes of the low-frequency plateau are discussed.","PeriodicalId":16991,"journal":{"name":"Journal of Rheology","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rheology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1122/8.0000488","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MECHANICS","Score":null,"Total":0}
引用次数: 2
Abstract
A thorough study is made of the dependences on salt concentration and polymer chain lengths of the low-frequency plateau of coacervates of poly (diallyl dimethyl ammonium chloride), PDADMAC, and poly (sodium 4-styrenesulfonate), PSS. The reliability and reproducibility of these measurements are carefully checked by determining the frequency-dependent stress limits of the rheometer through the use of reference fluids and by repeat experiments with coacervates. Long-time frequency sweeps show that coacervates with less salt are more repeatable than those with higher salt. A low-frequency plateau reliably appears only below a critical salt concentration, and the magnitude of the plateau depends strongly on salt concentration and chain lengths of both polycation and polyanion. It is only present for the molecular weight of the polycation, PDADMAC, higher than 100 kDa, but the magnitude of the plateau is more strongly influenced by the chain length of the polyanion, PSS. Possible causes of the low-frequency plateau are discussed.
期刊介绍:
The Journal of Rheology, formerly the Transactions of The Society of Rheology, is published six times per year by The Society of Rheology, a member society of the American Institute of Physics, through AIP Publishing. It provides in-depth interdisciplinary coverage of theoretical and experimental issues drawn from industry and academia. The Journal of Rheology is published for professionals and students in chemistry, physics, engineering, material science, and mathematics.