{"title":"Test-retest Reliability of Various Psychoacoustic Tests in Psycon Application","authors":"Supriya Mathew, Banumathi, Sandeep Kumar, Kishore Tanniru, Chandni Jain","doi":"10.18502/avr.v32i2.12171","DOIUrl":null,"url":null,"abstract":"Background and Aim: Psychoacoustics includes studying the perceived effects of changes in sound intensity, temporal, and frequency aspects that are critical for speech perception. Psycon is one such software used in studies to assess psychoacoustic abilities. Psycon has the potential for wide clinical applications in psychoacoustic research and relies on Auditory syntaX (AUX), a program designed specifically to handle auditory signals. The current study aimed to determine the test-retest reliability of the Psycon application for differential sensitivity measures of frequency, intensity, duration and silence. \nMethods: The study included 39 participants with normal hearing sensitivity. Psychoacoustic measures, namely, gap detection threshold, duration discrimination threshold, difference limen of intensity, and difference limen of frequency, were used to assess test-retest reliability. The test-retest reliability of all measures was checked in two separate sessions within one day. \nResults: The reliability of each measure was measured using Cronbach’s alpha. Test-retest reliability of various psychoacoustic tests measured with Psycon ranges from good to excellent. difference limen of frequency had the highest reliability, followed by duration discrimination thresholds, difference limen of intensity, and gap detection thresholds. \nConclusion: Psycon appears to be a reliable tool for assessing different psychoacoustic abilities. \nKeywords: Psycon; psychoacoustics; reliability; difference limen; perception","PeriodicalId":34089,"journal":{"name":"Auditory and Vestibular Research","volume":" ","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2023-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Auditory and Vestibular Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/avr.v32i2.12171","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

Background and Aim: Psychoacoustics includes studying the perceived effects of changes in sound intensity, temporal, and frequency aspects that are critical for speech perception. Psycon is one such software used in studies to assess psychoacoustic abilities. Psycon has the potential for wide clinical applications in psychoacoustic research and relies on Auditory syntaX (AUX), a program designed specifically to handle auditory signals. The current study aimed to determine the test-retest reliability of the Psycon application for differential sensitivity measures of frequency, intensity, duration and silence. Methods: The study included 39 participants with normal hearing sensitivity. Psychoacoustic measures, namely, gap detection threshold, duration discrimination threshold, difference limen of intensity, and difference limen of frequency, were used to assess test-retest reliability. The test-retest reliability of all measures was checked in two separate sessions within one day. Results: The reliability of each measure was measured using Cronbach’s alpha. Test-retest reliability of various psychoacoustic tests measured with Psycon ranges from good to excellent. difference limen of frequency had the highest reliability, followed by duration discrimination thresholds, difference limen of intensity, and gap detection thresholds. Conclusion: Psycon appears to be a reliable tool for assessing different psychoacoustic abilities. Keywords: Psycon; psychoacoustics; reliability; difference limen; perception
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Psycon应用中各种心理声学测试的复测信度
背景和目的:心理声学包括研究对语音感知至关重要的声强、时间和频率变化的感知效应。Psycon就是这样一款用于评估心理声学能力的软件。Psycon在心理声学研究中具有广泛的临床应用潜力,它依赖于听觉语法(AUX),一种专门设计用于处理听觉信号的程序。目前的研究旨在确定Psycon应用程序对频率、强度、持续时间和沉默的差异灵敏度测量的重测可靠性。方法:39例听力正常的受试者。采用间隙检测阈值、持续时间分辨阈值、强度差异阈值和频率差异阈值等心理声学测量来评估重测信度。所有测量的重测信度在一天内的两次单独的会议中进行检查。结果:采用Cronbach 's alpha测量各测量的信度。用Psycon测量的各种心理声学测试的重测信度从好到优不等。信度最高的是频率差异阈值,其次是时间区分阈值、强度差异阈值和间隙检测阈值。结论:Psycon似乎是评估不同心理声学能力的可靠工具。关键词:Psycon;心理声学;可靠性;差别阈限;感知
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Auditory and Vestibular Research
Auditory and Vestibular Research Medicine-Otorhinolaryngology
CiteScore
0.60
自引率
20.00%
发文量
0
审稿时长
12 weeks
期刊最新文献
Clinical Characteristics and Hearing Aid Uptake Rate of Patients Seen at the Community Hearing Clinic: A Model of Upstream Preventive Care and Earlier Intervention The Use of Homotonic Monosyllabic Words in the Persian Language for the Word-in-Noise Perception Test Development of a Smart Game Application for Auditory Training of Children with Spatial Processing Disorder in Iran: A Pilot Study Investigating the Effect of Persian Phonemic Synthesis Program in Cochlear Implant Users with Phoneme Processing Dificulities Effect of Vestibular Rehabilitation Therapy on the Daily Life Aspects of Military Men with Persistent Postural- Perceptual Dizziness: A Clinical Trial
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1