Practical Applications

IF 1.5 4区 工程技术 Q3 CONSTRUCTION & BUILDING TECHNOLOGY Building Services Engineering Research & Technology Pub Date : 2022-08-26 DOI:10.1177/01436244221117954
{"title":"Practical Applications","authors":"","doi":"10.1177/01436244221117954","DOIUrl":null,"url":null,"abstract":"overspeed governor velocity measuring system uses a for This new process may replace the inaccurate measuring system currently employed by maintenance tech-nicians, thus its reliability. The main objective consists of rigorously testing the operation of overspeed governors. The developed system guarantees the automatic execution of the test under several anomalous operating situations, thus allowing the user to have real-time access to the test data obtained through a graphical interface available on a mobile electronic device. This study proposes a novel control framework that jointly controls portable home air puri fi ers (HAPs) and windows to maintain thermal comfort and achieve effective PM 2.5 removal. The simulation results suggest that such a hybrid control strategy can result in considerable health bene fi ts at low additional energy costs. de-tectability and cance. Regarding the framework prioritizes hard faults over sequencing logic faults to avoid false positives and false negatives; about signi fi cance, system-level faults are prioritized over zone-level faults to triage high-impact faults in the system. The detection of faults is performed via visualizing the biases from the expected behaviour of AHU and VAV characteristics to provide an envisioning interpretation for the experts in facilities man-agement in commercial buildings to fi nd the root cause of the fault and fi x them on-site. District Cooling Systems are considered as a promising solution to alleviate the climate change issue. An optimized chiller sequencing control strategy of DCS can effectively reduce overall cooling energy consumption, so as to achieve carbon neutrality. This paper outlines a case study on a costeffective operational control strategy of the DCS at HZMB-HKP. The analysis of both the theoretical and practical sequencing control strategy can be taken as a reference for DCS development in the future.","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":"43 1","pages":"537 - 538"},"PeriodicalIF":1.5000,"publicationDate":"2022-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building Services Engineering Research & Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01436244221117954","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 2

Abstract

overspeed governor velocity measuring system uses a for This new process may replace the inaccurate measuring system currently employed by maintenance tech-nicians, thus its reliability. The main objective consists of rigorously testing the operation of overspeed governors. The developed system guarantees the automatic execution of the test under several anomalous operating situations, thus allowing the user to have real-time access to the test data obtained through a graphical interface available on a mobile electronic device. This study proposes a novel control framework that jointly controls portable home air puri fi ers (HAPs) and windows to maintain thermal comfort and achieve effective PM 2.5 removal. The simulation results suggest that such a hybrid control strategy can result in considerable health bene fi ts at low additional energy costs. de-tectability and cance. Regarding the framework prioritizes hard faults over sequencing logic faults to avoid false positives and false negatives; about signi fi cance, system-level faults are prioritized over zone-level faults to triage high-impact faults in the system. The detection of faults is performed via visualizing the biases from the expected behaviour of AHU and VAV characteristics to provide an envisioning interpretation for the experts in facilities man-agement in commercial buildings to fi nd the root cause of the fault and fi x them on-site. District Cooling Systems are considered as a promising solution to alleviate the climate change issue. An optimized chiller sequencing control strategy of DCS can effectively reduce overall cooling energy consumption, so as to achieve carbon neutrality. This paper outlines a case study on a costeffective operational control strategy of the DCS at HZMB-HKP. The analysis of both the theoretical and practical sequencing control strategy can be taken as a reference for DCS development in the future.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
实际应用
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Building Services Engineering Research & Technology
Building Services Engineering Research & Technology 工程技术-结构与建筑技术
CiteScore
4.30
自引率
5.90%
发文量
38
审稿时长
>12 weeks
期刊介绍: Building Services Engineering Research & Technology is one of the foremost, international peer reviewed journals that publishes the highest quality original research relevant to today’s Built Environment. Published in conjunction with CIBSE, this impressive journal reports on the latest research providing you with an invaluable guide to recent developments in the field.
期刊最新文献
Frost suppression performance of an air source heat pump using sensible heat from indoor air to preheat outdoor air A revised PMV model: From a physiological standpoint Prediction models of bioaerosols inside office buildings: A field study investigation An overheating criterion for bedrooms in temperate climates: Derivation and application The influence of different offset modes on the drainage characteristics of a double stack drainage system in a high-rise building
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1