A. Nitasari, C. Anam, W. Budi, A. L. Wati, S. Syarifudin, G. Dougherty
{"title":"Comparisons of Water-Equivalent Diameter Measured on Images of Abdominal Routine Computed Tomography with and without A Contrast Agent","authors":"A. Nitasari, C. Anam, W. Budi, A. L. Wati, S. Syarifudin, G. Dougherty","doi":"10.17146/aij.2021.1112","DOIUrl":null,"url":null,"abstract":"Normal 0 false false false EN-ID JA AR-SA /* Style Definitions */ \n table.MsoNormalTable \n {mso-style-name:\"Table Normal\"; \n mso-tstyle-rowband-size:0; \n mso-tstyle-colband-size:0; \n mso-style-noshow:yes; \n mso-style-priority:99; \n mso-style-parent:\"\"; \n mso-padding-alt:0cm 5.4pt 0cm 5.4pt; \n mso-para-margin:0cm; \n mso-para-margin-bottom:.0001pt; \n mso-pagination:widow-orphan; \n font-size:10.0pt; \n font-family:\"Times New Roman\",serif; \n mso-ansi-language:EN-ID;} \n The size-specific dose estimate (SSDE) is a metric for an estimation of patient dose in computed tomography (CT). The SSDE strongly depends on the water-equivalent diameter (D W ). In abdominal CT examinations, a contrast agent is sometimes used to more clearly visualize tissue lesions. The Hounsfield unit (HU) of CT images with and without the use of a contrast agent at specific areas is slightly different and it may affect the D W value. This study aimed to compare the D W values calculated from axial CT images in patients who had undergone routine abdominal scans both with and without the use of a contrast agent. Axial images of 144 patients with a weight range of 3.5 kg to 90 kg who had undergone routine abdominal scans both with and without the use of a contrast agent using a Siemens Sensation 64 CT scanner were retrospectively collected. The D W values were automatically calculated using the Matlab-based IndoseCT (version 15a) software. The results show the percentage difference between D W,contrast and D W,non - contrast is below 2 %. As a result, the mean SSDE contrast is 1.5 % smaller than SSDE non - contrast . Due to the effect of a contrast agent on the D W and SSDE value s is below 2 %, the axial images of CT abdomen without the use of a contrast agent can be used as the accurate estimation of D W and SSDE for images with the use of a contrast agent. Normal 0 false false false EN-ID JA AR-SA /* Style Definitions */ \n table.MsoNormalTable \n {mso-style-name:\"Table Normal\"; \n mso-tstyle-rowband-size:0; \n mso-tstyle-colband-size:0; \n mso-style-noshow:yes; \n mso-style-priority:99; \n mso-style-parent:\"\"; \n mso-padding-alt:0cm 5.4pt 0cm 5.4pt; \n mso-para-margin:0cm; \n mso-para-margin-bottom:.0001pt; \n mso-pagination:widow-orphan; \n font-size:10.0pt; \n font-family:\"Times New Roman\",\"serif\"; \n mso-ansi-language:EN-ID; \n mso-fareast-language:EN-US;}","PeriodicalId":8647,"journal":{"name":"Atom Indonesia","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2021-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atom Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17146/aij.2021.1112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 2
Abstract
Normal 0 false false false EN-ID JA AR-SA /* Style Definitions */
table.MsoNormalTable
{mso-style-name:"Table Normal";
mso-tstyle-rowband-size:0;
mso-tstyle-colband-size:0;
mso-style-noshow:yes;
mso-style-priority:99;
mso-style-parent:"";
mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
mso-para-margin:0cm;
mso-para-margin-bottom:.0001pt;
mso-pagination:widow-orphan;
font-size:10.0pt;
font-family:"Times New Roman",serif;
mso-ansi-language:EN-ID;}
The size-specific dose estimate (SSDE) is a metric for an estimation of patient dose in computed tomography (CT). The SSDE strongly depends on the water-equivalent diameter (D W ). In abdominal CT examinations, a contrast agent is sometimes used to more clearly visualize tissue lesions. The Hounsfield unit (HU) of CT images with and without the use of a contrast agent at specific areas is slightly different and it may affect the D W value. This study aimed to compare the D W values calculated from axial CT images in patients who had undergone routine abdominal scans both with and without the use of a contrast agent. Axial images of 144 patients with a weight range of 3.5 kg to 90 kg who had undergone routine abdominal scans both with and without the use of a contrast agent using a Siemens Sensation 64 CT scanner were retrospectively collected. The D W values were automatically calculated using the Matlab-based IndoseCT (version 15a) software. The results show the percentage difference between D W,contrast and D W,non - contrast is below 2 %. As a result, the mean SSDE contrast is 1.5 % smaller than SSDE non - contrast . Due to the effect of a contrast agent on the D W and SSDE value s is below 2 %, the axial images of CT abdomen without the use of a contrast agent can be used as the accurate estimation of D W and SSDE for images with the use of a contrast agent. Normal 0 false false false EN-ID JA AR-SA /* Style Definitions */
table.MsoNormalTable
{mso-style-name:"Table Normal";
mso-tstyle-rowband-size:0;
mso-tstyle-colband-size:0;
mso-style-noshow:yes;
mso-style-priority:99;
mso-style-parent:"";
mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
mso-para-margin:0cm;
mso-para-margin-bottom:.0001pt;
mso-pagination:widow-orphan;
font-size:10.0pt;
font-family:"Times New Roman","serif";
mso-ansi-language:EN-ID;
mso-fareast-language:EN-US;}
期刊介绍:
The focus of Atom Indonesia is research and development in nuclear science and technology. The scope of this journal covers experimental and analytical research in nuclear science and technology. The topics include nuclear physics, reactor physics, radioactive waste, fuel element, radioisotopes, radiopharmacy, radiation, and neutron scattering, as well as their utilization in agriculture, industry, health, environment, energy, material science and technology, and related fields.