The Medial Triquetrohamate Portal: A New Portal in Wrist Arthroscopy. Anatomical Study.

Pub Date : 2023-07-28 eCollection Date: 2024-04-01 DOI:10.1055/s-0043-1771439
Francisco J Lucas, Vicente Carratalá, Ignacio Miranda, Sergio Pombo Alonso
{"title":"The Medial Triquetrohamate Portal: A New Portal in Wrist Arthroscopy. Anatomical Study.","authors":"Francisco J Lucas, Vicente Carratalá, Ignacio Miranda, Sergio Pombo Alonso","doi":"10.1055/s-0043-1771439","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction</b>  Continuing advances in wrist arthroscopy and better understanding of carpal conditions have created the need to design new wrist access portals that facilitate the implementation of new surgical techniques. The aim of this study was to define and verify the safety of the medial triquetrohamate (MTH) portal. <b>Description of the technique</b>  The MTH portal is located about 5-10 mm ulnar and 2-3 mm distal to the midcarpal ulnar portal, ulnar to the extensor digitorum communis (EDC) tendon of the fourth and fifth fingers, and radial to the extensor digiti quinti (minimi) (EDQ) tendon. <b>Methods</b>  An anatomical study was performed on 15 upper limb specimens from 15 human cadavers. Iatrogenic injuries to potentially at-risk neurovascular and tendinous structures were assessed, and the distance from the portal to these structures was measured. <b>Results</b>  There were no iatrogenic injuries to the structures at risk. Mean distances from the MTH portal to the EDC tendon of the fourth and fifth fingers and to the EDQ tendon were 4.67 ± 0.35 mm and 7.27 ± 0.18 mm, respectively. No differences were observed between the left and right wrists. The distance from the MTH portal to the dorsal sensory branch of the ulnar nerve was 15.07 ± 0.44 mm. The structure with the highest risk of injury was the EDC tendon of the fourth and fifth fingers, with a distance of less than 5 mm. <b>Conclusions</b>  The MTH portal is safe, reproducible and facilitates the implementation of various techniques related to midcarpal pathology.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10948239/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1771439","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction  Continuing advances in wrist arthroscopy and better understanding of carpal conditions have created the need to design new wrist access portals that facilitate the implementation of new surgical techniques. The aim of this study was to define and verify the safety of the medial triquetrohamate (MTH) portal. Description of the technique  The MTH portal is located about 5-10 mm ulnar and 2-3 mm distal to the midcarpal ulnar portal, ulnar to the extensor digitorum communis (EDC) tendon of the fourth and fifth fingers, and radial to the extensor digiti quinti (minimi) (EDQ) tendon. Methods  An anatomical study was performed on 15 upper limb specimens from 15 human cadavers. Iatrogenic injuries to potentially at-risk neurovascular and tendinous structures were assessed, and the distance from the portal to these structures was measured. Results  There were no iatrogenic injuries to the structures at risk. Mean distances from the MTH portal to the EDC tendon of the fourth and fifth fingers and to the EDQ tendon were 4.67 ± 0.35 mm and 7.27 ± 0.18 mm, respectively. No differences were observed between the left and right wrists. The distance from the MTH portal to the dorsal sensory branch of the ulnar nerve was 15.07 ± 0.44 mm. The structure with the highest risk of injury was the EDC tendon of the fourth and fifth fingers, with a distance of less than 5 mm. Conclusions  The MTH portal is safe, reproducible and facilitates the implementation of various techniques related to midcarpal pathology.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
腕部关节镜下的一种新门静脉。解剖研究
摘要:随着腕部关节镜技术的不断进步和对腕关节状况的更好了解,需要设计新的腕关节入口,以促进新手术技术的实施。本研究的目的是确定和验证内侧三骨臼门静脉(MTH)的安全性。MTH门静脉位于尺侧5-10毫米和腕中尺侧远端2-3毫米处,尺侧为第四和第五指的指共伸肌(EDC)肌腱,桡侧为指小伸肌(EDQ)肌腱。方法对15具人体尸体的15块上肢标本进行解剖研究。评估潜在危险神经血管和肌腱结构的医源性损伤,并测量从门静脉到这些结构的距离。结果无危险结构的医源性损伤。MTH门静脉到四、五指EDC肌腱和EDQ肌腱的平均距离分别为4.67±0.35 mm和7.27±0.18 mm。左手腕和右手腕之间没有观察到差异。MTH门静脉到尺神经背侧感觉支的距离为15.07±0.44 mm。损伤风险最高的结构是四指和五指的EDC肌腱,距离小于5mm。结论MTH门静脉安全、可重复性好,便于实施与腕中部病理相关的各种技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1