A Comparative Evaluation of Performance of Sysmex XN 3000 and Horiba Yumizen H2500 Automated Complete Blood Count Analysers.

IF 0.7 4区 医学 Q4 HEMATOLOGY Indian Journal of Hematology and Blood Transfusion Pub Date : 2024-04-01 Epub Date: 2023-08-17 DOI:10.1007/s12288-023-01687-6
Rajesh Kumar Bhola, Christophe Fudaly, Shubham Rastogi
{"title":"A Comparative Evaluation of Performance of Sysmex XN 3000 and Horiba Yumizen H2500 Automated Complete Blood Count Analysers.","authors":"Rajesh Kumar Bhola, Christophe Fudaly, Shubham Rastogi","doi":"10.1007/s12288-023-01687-6","DOIUrl":null,"url":null,"abstract":"<p><p>Modern automated laboratory haematology analysers use various methods to measure different haematological parameters. These parameters are useful in the diagnostic and clinical interpretation of patient symptoms. So, it is very important to compare the performance of different analysers measuring the same parameter. Hence, a comparison of complete blood counts analysed by Sysmex XN 3000 and Horiba Yumizen H2500 was performed. Total 296 EDTA anti-coagulated blood samples were processed in both the analysers in duplicate within 4 h of collection. The white blood cell count, red blood cell count, erythrocyte indices, differential leukocyte count, platelet count and platelet indices and reticulocyte count were compared. A good level of correlation and agreement between different parameters were obtained. A strong correlation was observed (r > 0.9) between Sysmex XN 3000 and Yumizen H2500 for WBC (0.997), RBC (0.997), Haemoglobin (0.999), haematocrit (0.974), MCV (0.902), MCH (0.99),, platelet count by impedance (0.989), mean platelet volume (0.954), plateletcrit (0.971), platelet distribution width (PDW) (0.916), neutrophils (0.997), lymphocytes (0.989), monocytes (0.943), and eosinophils (0.991) counts. A moderate correlation was observed for RDW-CV (0.75). The basophils count showed poor correlation (r < 0.5) possibly because of sample selection with mostly low basophils count. An acceptable bias was observed for most of the parameters like WBC, RBC, Haemoglobin, Haematocrit, platelet counts, neutrophils, lymphocytes, eosinophils and monocytes. The studied instruments ensured satisfactory interchangeability except for few parameters, thus facilitate substitution of one analyser by another without affecting the clinical decision making.</p>","PeriodicalId":49188,"journal":{"name":"Indian Journal of Hematology and Blood Transfusion","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11065844/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Hematology and Blood Transfusion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12288-023-01687-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/17 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Modern automated laboratory haematology analysers use various methods to measure different haematological parameters. These parameters are useful in the diagnostic and clinical interpretation of patient symptoms. So, it is very important to compare the performance of different analysers measuring the same parameter. Hence, a comparison of complete blood counts analysed by Sysmex XN 3000 and Horiba Yumizen H2500 was performed. Total 296 EDTA anti-coagulated blood samples were processed in both the analysers in duplicate within 4 h of collection. The white blood cell count, red blood cell count, erythrocyte indices, differential leukocyte count, platelet count and platelet indices and reticulocyte count were compared. A good level of correlation and agreement between different parameters were obtained. A strong correlation was observed (r > 0.9) between Sysmex XN 3000 and Yumizen H2500 for WBC (0.997), RBC (0.997), Haemoglobin (0.999), haematocrit (0.974), MCV (0.902), MCH (0.99),, platelet count by impedance (0.989), mean platelet volume (0.954), plateletcrit (0.971), platelet distribution width (PDW) (0.916), neutrophils (0.997), lymphocytes (0.989), monocytes (0.943), and eosinophils (0.991) counts. A moderate correlation was observed for RDW-CV (0.75). The basophils count showed poor correlation (r < 0.5) possibly because of sample selection with mostly low basophils count. An acceptable bias was observed for most of the parameters like WBC, RBC, Haemoglobin, Haematocrit, platelet counts, neutrophils, lymphocytes, eosinophils and monocytes. The studied instruments ensured satisfactory interchangeability except for few parameters, thus facilitate substitution of one analyser by another without affecting the clinical decision making.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Sysmex xn3000和堀场Yumizen H2500全自动全血细胞计数分析仪性能的比较评价
现代自动化实验室血液分析仪使用各种方法测量不同的血液参数。这些参数有助于诊断和临床解释病人的症状。因此,比较测量同一参数的不同分析仪的性能非常重要。因此,我们对 Sysmex XN 3000 和 Horiba Yumizen H2500 分析的全血细胞计数进行了比较。两种分析仪在采集后 4 小时内重复处理了 296 份 EDTA 抗凝血样本。比较了白细胞计数、红细胞计数、红细胞指数、白细胞计数差值、血小板计数和血小板指数以及网织红细胞计数。不同参数之间具有良好的相关性和一致性。Sysmex XN 3000 和 Yumizen H2500 在白细胞(0.997)、红细胞(0.997)、血红蛋白(0.999)、血细胞比容(0.974)、MCV(0.902)、MCH(0.99)、阻抗法血小板计数(0.989)、平均血小板体积(0.954)、血小板crit(0.971)、血小板分布宽度(PDW)(0.916)、中性粒细胞(0.997)、淋巴细胞(0.989)、单核细胞(0.943)和嗜酸性粒细胞(0.991)计数。RDW-CV 的相关性为中等(0.75)。嗜碱性粒细胞计数的相关性较差(r
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
82
审稿时长
>12 weeks
期刊介绍: Indian Journal of Hematology and Blood Transfusion is a medium for propagating and exchanging ideas within the medical community. It publishes peer-reviewed articles on a variety of aspects of clinical hematology, laboratory hematology and hemato-oncology. The journal exists to encourage scientific investigation in the study of blood in health and in disease; to promote and foster the exchange and diffusion of knowledge relating to blood and blood-forming tissues; and to provide a forum for discussion of hematological subjects on a national scale. The Journal is the official publication of The Indian Society of Hematology & Blood Transfusion.
期刊最新文献
Clinico-Pathological Significance and Prognostic Impact of Various PML RARA Transcripts on Outcomes in Acute Promyelocytic Myeloid Leukemia (APML) Treated with Single Agent Arsenic Trioxide(ATO)- Insights from a Tertiary Cancer Center in South India When Eosinophils Speak: A Case of Strongyloides stercoralis Infection Navigating the Challenges of Bombay Phenotype (Oh) and Leukemia A Pedigree Investigation of H-antigen Deletion Caused by Mutation of 658 C to T in the FUT1 Gene. Haploidentical Hematopoietic Stem Cell Transplantation in India-Bridging the Gap.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1