{"title":"Development of a high-performance blast energy-absorbing system for building structures","authors":"G. Gomes, V. Lúcio, C. Cismaşiu","doi":"10.1177/20414196231183006","DOIUrl":null,"url":null,"abstract":"Shock absorbers have been widely used in the automotive and aeronautical industries for many years. Inspired on these devices, the paper presents an analytical and numerical assessment of a high performance protective system for building structures against blast loads, which is composed of a shielding element connected to the main structure, at the floor levels, through ductile Energy Absorbing Connectors (EACs). The EACs exploit the external tube inversion mechanism to absorb a significant part of the imparted kinetic energy from the blast wave. While the system prototype has been developed in laboratory, it was characterized and tested in a full-scale blast testing campaign. A validated finite element model was used next to analyze its performance in a more demanding design scenario. The introduction of EACs notably reduces the peak horizontal loads and the kinetic energy transferred to the protected structure, being expected a significant reduction of the stresses in the supporting vertical elements, in addition to the protection of structural and non-structural members. These results encourage further studies of the presented protective system that can be potentially employed for a large variety of blast threat scenarios, especially when increasing the stand-off is not a possible/viable option and sensitive facilities have to be protected.","PeriodicalId":46272,"journal":{"name":"International Journal of Protective Structures","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2023-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Protective Structures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20414196231183006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0
Abstract
Shock absorbers have been widely used in the automotive and aeronautical industries for many years. Inspired on these devices, the paper presents an analytical and numerical assessment of a high performance protective system for building structures against blast loads, which is composed of a shielding element connected to the main structure, at the floor levels, through ductile Energy Absorbing Connectors (EACs). The EACs exploit the external tube inversion mechanism to absorb a significant part of the imparted kinetic energy from the blast wave. While the system prototype has been developed in laboratory, it was characterized and tested in a full-scale blast testing campaign. A validated finite element model was used next to analyze its performance in a more demanding design scenario. The introduction of EACs notably reduces the peak horizontal loads and the kinetic energy transferred to the protected structure, being expected a significant reduction of the stresses in the supporting vertical elements, in addition to the protection of structural and non-structural members. These results encourage further studies of the presented protective system that can be potentially employed for a large variety of blast threat scenarios, especially when increasing the stand-off is not a possible/viable option and sensitive facilities have to be protected.