GripAble: An accurate, sensitive and robust digital device for measuring grip strength

M. Mace, S. A. Mutalib, M. Ogrinc, N. Goldsmith, E. Burdet
{"title":"GripAble: An accurate, sensitive and robust digital device for measuring grip strength","authors":"M. Mace, S. A. Mutalib, M. Ogrinc, N. Goldsmith, E. Burdet","doi":"10.1177/20556683221078455","DOIUrl":null,"url":null,"abstract":"Introduction Grip strength is a reliable biomarker of overall health and physiological well-being. It is widely used in clinical practice as an outcome measure. This paper demonstrates the measurement characteristics of GripAble, a wireless mobile handgrip device that measures grip force both isometrically and elastically-resisted for assessment and training of hand function. Methods A series of bench tests were performed to evaluate GripAble's grip force measurement accuracy and sensitivity. Measurement robustness was evaluated through repeated drop tests interwoven with error verification test phases. Results GripAble's absolute measurement error at the central position was under 0.81 and 1.67 kg (95th percentiles; N = 47) when measuring elastically and isometrically, respectively, providing similar or better accuracy than the industry-standard Jamar device. Sensitivity was measured as 0.062 ± 0.015 kg (mean ± std; 95th percentiles: [0.036, 0.089] kg; N = 47), independent of the applied force. There was no significant performance degradation following impact from 30 drops from a height >1.5 m. Conclusion GripAble is an accurate and reliable grip strength dynamometer. It is highly sensitive and robust, which in combination with other novel features (e.g. portability, telerehabilitation and digital data tracking) enable broad applicability in a range of clinical caseloads and environments.","PeriodicalId":43319,"journal":{"name":"Journal of Rehabilitation and Assistive Technologies Engineering","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation and Assistive Technologies Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20556683221078455","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 4

Abstract

Introduction Grip strength is a reliable biomarker of overall health and physiological well-being. It is widely used in clinical practice as an outcome measure. This paper demonstrates the measurement characteristics of GripAble, a wireless mobile handgrip device that measures grip force both isometrically and elastically-resisted for assessment and training of hand function. Methods A series of bench tests were performed to evaluate GripAble's grip force measurement accuracy and sensitivity. Measurement robustness was evaluated through repeated drop tests interwoven with error verification test phases. Results GripAble's absolute measurement error at the central position was under 0.81 and 1.67 kg (95th percentiles; N = 47) when measuring elastically and isometrically, respectively, providing similar or better accuracy than the industry-standard Jamar device. Sensitivity was measured as 0.062 ± 0.015 kg (mean ± std; 95th percentiles: [0.036, 0.089] kg; N = 47), independent of the applied force. There was no significant performance degradation following impact from 30 drops from a height >1.5 m. Conclusion GripAble is an accurate and reliable grip strength dynamometer. It is highly sensitive and robust, which in combination with other novel features (e.g. portability, telerehabilitation and digital data tracking) enable broad applicability in a range of clinical caseloads and environments.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
可抓握:一种精确,灵敏和强大的数字设备,用于测量握力
引言握力是整体健康和生理健康的可靠生物标志物。它在临床实践中被广泛用作一种结果测量。本文演示了GripAble的测量特性,这是一种无线移动握把设备,可以测量等距和弹性抵抗的握力,用于评估和训练手部功能。方法通过一系列台架试验,对GripAble握力测量的准确性和灵敏度进行评价。通过与误差验证测试阶段交织的重复跌落测试来评估测量稳健性。结果当弹性测量和等距测量时,GripAble在中心位置的绝对测量误差分别低于0.81和1.67kg(95%;N=47),提供了与行业标准Jamar设备相似或更好的精度。灵敏度测量为0.062±0.015 kg(平均值±标准差;第95个百分位数:[0.0360.089]kg;N=47),与施加的力无关。从1.5米以上的高度跌落30次后,性能没有显著下降。结论GripAble是一种准确可靠的握力测功机。它具有高度的灵敏度和鲁棒性,与其他新颖功能(如便携性、远程康复和数字数据跟踪)相结合,能够在一系列临床病例和环境中广泛应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
5.00%
发文量
37
期刊最新文献
Artificial intelligence approach for detecting and classifying abnormal behaviour in older adults using wearable sensors. Designing feelings into lower-limb prostheses - A kansei engineering approach to understand lower-limb prosthetic cosmeses. Public opinion on types of voice systems for older adults. Initial feasibility evaluation of the RISES system: An innovative and activity-based closed-loop framework for spinal cord injury rehabilitation and recovery. Inclusive rehabilitation and assistive technologies development: An exploration of considerations, principles, and stakeholder engagement.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1