T1 and T2 Mappings in the Early Diagnosis of Achilles Tendinosis

Zeineb Tbini, M. Mars, M. Chelli
{"title":"T1 and T2 Mappings in the Early Diagnosis of Achilles Tendinosis","authors":"Zeineb Tbini, M. Mars, M. Chelli","doi":"10.2174/1874220301603010083","DOIUrl":null,"url":null,"abstract":"\n \n The purpose of this study was to compare T1 and T2 relaxation times of normal and pathologic Achilles Tendon (AT) in order to evaluate the ability of these methods to detect early Achilles tendon tendinosis.\n \n \n \n Forty-eight subjects were included in this study. Twenty-two subjects were classified as normal group and twenty-six subjects as patient group with tendinosis. MR examination was performed by 3 Tesla scanner using a 12 channel head coil. For relaxation times quantification, we used a sagittal 3D FLASH variable flip angle gradient echo UTE sequence (3D VFA-GE UTE) for T1 mapping and a sagittal Multi Echo Spin Echo sequence (MESE) for T2 mapping. Relaxation times were quantified using two different algorithms written in MATLAB. P value < 0.05 was considered statistically significant.\n \n \n \n Our results showed a statistically significant difference in T1 and T2 values for the normal group compared to the patient group (p<0.05). Mean values of T1 and T2 were 571.69 ms and 24.16 ms for the normal group and 818.10 ms and 32.43 ms for the patient group, respectively. Results reported no correlation (r=0.193) for T1 mapping and a positive significant moderate correlation (r=0.542, p=0.000) for T2 mapping between the normal and patient groups. T1 and T2 showed no correlation in the normal group (r= 0.091, p=0.489) and a positive significant weak correlation in the patient group (r=0.263, p=0.048).\n \n \n \n We concluded that T1 and T2 relaxation times are relatively sensitive to diagnosis degenerative changes in the AT and T1 is more sensitive to AT tendinosis compared to T2.\n","PeriodicalId":91371,"journal":{"name":"Open medicine journal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open medicine journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874220301603010083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The purpose of this study was to compare T1 and T2 relaxation times of normal and pathologic Achilles Tendon (AT) in order to evaluate the ability of these methods to detect early Achilles tendon tendinosis. Forty-eight subjects were included in this study. Twenty-two subjects were classified as normal group and twenty-six subjects as patient group with tendinosis. MR examination was performed by 3 Tesla scanner using a 12 channel head coil. For relaxation times quantification, we used a sagittal 3D FLASH variable flip angle gradient echo UTE sequence (3D VFA-GE UTE) for T1 mapping and a sagittal Multi Echo Spin Echo sequence (MESE) for T2 mapping. Relaxation times were quantified using two different algorithms written in MATLAB. P value < 0.05 was considered statistically significant. Our results showed a statistically significant difference in T1 and T2 values for the normal group compared to the patient group (p<0.05). Mean values of T1 and T2 were 571.69 ms and 24.16 ms for the normal group and 818.10 ms and 32.43 ms for the patient group, respectively. Results reported no correlation (r=0.193) for T1 mapping and a positive significant moderate correlation (r=0.542, p=0.000) for T2 mapping between the normal and patient groups. T1 and T2 showed no correlation in the normal group (r= 0.091, p=0.489) and a positive significant weak correlation in the patient group (r=0.263, p=0.048). We concluded that T1 and T2 relaxation times are relatively sensitive to diagnosis degenerative changes in the AT and T1 is more sensitive to AT tendinosis compared to T2.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
T1和T2映射在跟腱炎早期诊断中的应用
本研究的目的是比较正常和病理跟腱(AT)的T1和T2松弛时间,以评估这些方法检测早期跟腱肌腱病变的能力。本研究共纳入48名受试者。22例为正常组,26例为肌腱病患者组。磁共振检查采用3特斯拉扫描仪,采用12通道头线圈。为了量化松弛时间,我们使用了矢状面3D FLASH可变翻转角梯度回波序列(3D VFA-GE UTE)进行T1映射,使用矢状面多回波自旋回波序列(MESE)进行T2映射。使用MATLAB编写的两种不同算法对松弛时间进行量化。P值< 0.05为差异有统计学意义。结果显示,正常组T1、T2值与患者组比较差异有统计学意义(p<0.05)。正常组T1和T2均值分别为571.69 ms和24.16 ms,患者组T1和T2均值分别为818.10 ms和32.43 ms。结果显示,正常组和患者组T1映射无相关性(r=0.193), T2映射呈正相关(r=0.542, p=0.000)。正常组T1与T2无相关性(r= 0.091, p=0.489),患者组T1与T2呈显著正相关(r=0.263, p=0.048)。我们得出结论,T1和T2的松弛时间对诊断AT的退行性改变相对敏感,T1比T2对AT肌腱病变更敏感。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
China Against Drug Resistance (CARE) Point Prevalence Study: A Tool for Evaluating Hospital Acquired Infections and Antimicrobial Prescription at Patient Bedside CLEC4A Expression as a Prognostic Biomarker and Immunoregulator in Lung Adenocarcinoma: Insights from Immune Cell Infiltration Value of the A2DS2 Score Combined with the Neutrophil-to-lymphocyte Ratio in Predicting Acute Ischemic Stroke-associated Pneumonia Systemic Lupus Erythematosus in a Patient with Liver Cirrhosis: Case Report and Literature Review Comparing the Effectiveness and Safety of Anterior Cervical Discectomy and Fusion with Four Different Fixation Systems: A Systematic Review and Network Meta-analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1