Detection of Selenium and Nickel Metal Ion in Water Using Mn3O4-Cn-Modified Electrode

IF 2.3 Q3 ELECTROCHEMISTRY International journal of electrochemistry Pub Date : 2021-05-31 DOI:10.1155/2021/6650542
N. John, K. E. Abraham
{"title":"Detection of Selenium and Nickel Metal Ion in Water Using Mn3O4-Cn-Modified Electrode","authors":"N. John, K. E. Abraham","doi":"10.1155/2021/6650542","DOIUrl":null,"url":null,"abstract":"The present study reports the design of the Mn3O4-Cn electrode and its use for simultaneous detection of selenium and nickel in water. The designed electrode can be used as a convenient electrochemical device for on-site testing of Se (IV) and Ni (II) levels in affected regions. The best responses are obtained with 0.1 M phosphate buffer saline (PBS) and 5 mM Fe (CN)6 as supporting electrolyte. The scan rate and the number of cyclic repetitions have a great effect on peak shape and intensity. It is seen from our study that peak intensity is directly proportional to Se (IV) and Ni (II) concentrations in the range of 5 to 250 µg/L (correlation coefficients 0.952 and 0.984) when the optimized parameters are used. The detection limit of 0.533 µg/L Se (IV) and 0.718 µg/L for Ni (VI) with a response time of 18 s for 5–250 µg/L concentration is obtained, respectively. Enhanced analytical results for different water samples establish that the proposed method is appropriate for Se (IV) and Ni (II) detection. FESEM images confirm the Mn3O4-Cn nanocomposite formation on the electrode.","PeriodicalId":13933,"journal":{"name":"International journal of electrochemistry","volume":"2021 1","pages":"1-9"},"PeriodicalIF":2.3000,"publicationDate":"2021-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of electrochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2021/6650542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 2

Abstract

The present study reports the design of the Mn3O4-Cn electrode and its use for simultaneous detection of selenium and nickel in water. The designed electrode can be used as a convenient electrochemical device for on-site testing of Se (IV) and Ni (II) levels in affected regions. The best responses are obtained with 0.1 M phosphate buffer saline (PBS) and 5 mM Fe (CN)6 as supporting electrolyte. The scan rate and the number of cyclic repetitions have a great effect on peak shape and intensity. It is seen from our study that peak intensity is directly proportional to Se (IV) and Ni (II) concentrations in the range of 5 to 250 µg/L (correlation coefficients 0.952 and 0.984) when the optimized parameters are used. The detection limit of 0.533 µg/L Se (IV) and 0.718 µg/L for Ni (VI) with a response time of 18 s for 5–250 µg/L concentration is obtained, respectively. Enhanced analytical results for different water samples establish that the proposed method is appropriate for Se (IV) and Ni (II) detection. FESEM images confirm the Mn3O4-Cn nanocomposite formation on the electrode.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用mn3o4 - cn修饰电极检测水中硒和镍金属离子
本研究报告了Mn3O4-Cn电极的设计及其在同时检测水中硒和镍中的应用。所设计的电极可作为一种方便的电化学装置,用于受影响地区Se(IV)和Ni(II)水平的现场测试。最佳响应为0.1 M磷酸盐缓冲盐水(PBS)和5 mM Fe(CN)6作为支撑电解质。扫描速率和循环重复次数对峰值形状和强度有很大影响。从我们的研究中可以看出,在5-250的范围内,峰值强度与Se(IV)和Ni(II)浓度成正比 µg/L(相关系数0.952和0.984)。检测限0.533 µg/L Se(IV)和0.718 µg/L的Ni(VI),响应时间为18 s代表5–250 分别获得µg/L的浓度。对不同水样的增强分析结果表明,所提出的方法适用于Se(IV)和Ni(II)的检测。FESEM图像证实了Mn3O4-Cn纳米复合材料在电极上的形成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
2
审稿时长
7 weeks
期刊最新文献
Effect of Surface Composition on Electrochemical Oxidation Reaction of Carbon Monoxide and Ethanol of PtxRh1−x Solid Solution Electrodes Development and Characterization of a New Solid Polymer Electrolyte for Supercapacitor Device Size-Dependent Chlorinated Nitrogen-Doped Carbon Nanotubes: Their Use as Electrochemical Detectors for Catechol and Resorcinol Enabling the Electrochemical Performance of Maricite-NaMnPO4 and Maricite-NaFePO4 Cathode Materials in Sodium-Ion Batteries Electrooxidation and Development of a Highly Sensitive Electrochemical Probe for Trace Determination of the Steroid 11-Desoxycorticosterone Drug Residues in Water
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1