Electrochemical Oxidation Approach towards the Treatment of Acetamiprid Pesticide from Polluted Water

M. Dolatabadi, Z. Hajebrahimi, Roya Malekahmadi, Saeid Ahmadzadeh
{"title":"Electrochemical Oxidation Approach towards the Treatment of Acetamiprid Pesticide from Polluted Water","authors":"M. Dolatabadi, Z. Hajebrahimi, Roya Malekahmadi, Saeid Ahmadzadeh","doi":"10.18502/jehsd.v7i1.8966","DOIUrl":null,"url":null,"abstract":"Introduction: Acetamiprid (AP) is one of the most widely used pesticides in the neonicotinoid class. AP residues in the environment have received considerable due to their potential toxicity to humans. Therefore, it is important to remove AP from the aqueous solution. \nMaterials and Methods: In the current study, response surface methodology (RSM) was used as an efficient approach to optimize the removal of AP using the electro-Fenton (EF) process. The effects of the main variables, including reaction time, AP concentration, current density, and H2O2 dosage were investigated and optimized. ANOVA technique was also used to identify the Fisher’s value (F-value) and P-value of the model. \nResults: The predicted AP removal efficiency by the model was in good agreement with the obtained experimental results with correlation regression of 0.9885. The ANOVA test proved that the developed quadratic model was significant with very low P-values less than 0.05, the high F-value of 240.1, and regression coefficients close to 1 at a 95% confidence level. The optimum condition for AP removal efficiency of 99.02% was attained at the reaction time of 12 min, AP concentration of 3.5 mg L-1, the current density of 12 mA cm-2, and H2O2 dosage of 86 µL. \nConclusion: RSM was employed as a suitable method to optimize the operating condition and maximize the AP removal. Herein, the EF process as an eco-friendly electrochemical advanced oxidation process (EAOP) successfully applied to remove AP from the water and wastewater.","PeriodicalId":53380,"journal":{"name":"Journal of Environmental Health and Sustainable Development","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Health and Sustainable Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/jehsd.v7i1.8966","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 5

Abstract

Introduction: Acetamiprid (AP) is one of the most widely used pesticides in the neonicotinoid class. AP residues in the environment have received considerable due to their potential toxicity to humans. Therefore, it is important to remove AP from the aqueous solution. Materials and Methods: In the current study, response surface methodology (RSM) was used as an efficient approach to optimize the removal of AP using the electro-Fenton (EF) process. The effects of the main variables, including reaction time, AP concentration, current density, and H2O2 dosage were investigated and optimized. ANOVA technique was also used to identify the Fisher’s value (F-value) and P-value of the model. Results: The predicted AP removal efficiency by the model was in good agreement with the obtained experimental results with correlation regression of 0.9885. The ANOVA test proved that the developed quadratic model was significant with very low P-values less than 0.05, the high F-value of 240.1, and regression coefficients close to 1 at a 95% confidence level. The optimum condition for AP removal efficiency of 99.02% was attained at the reaction time of 12 min, AP concentration of 3.5 mg L-1, the current density of 12 mA cm-2, and H2O2 dosage of 86 µL. Conclusion: RSM was employed as a suitable method to optimize the operating condition and maximize the AP removal. Herein, the EF process as an eco-friendly electrochemical advanced oxidation process (EAOP) successfully applied to remove AP from the water and wastewater.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电化学氧化法处理污水中啶虫脒农药的研究
前言:乙酰胺磷(AP)是新烟碱类农药中应用最广泛的一种。AP在环境中的残留由于其对人类的潜在毒性而受到重视。因此,从水溶液中去除AP是很重要的。材料和方法:在本研究中,响应面法(RSM)被用作优化电芬顿(EF)工艺去除AP的有效方法。研究并优化了反应时间、AP浓度、电流密度和H2O2用量等主要变量的影响。ANOVA技术也被用于识别模型的Fisher值(F值)和P值。结果:模型预测的AP去除率与实验结果吻合较好,相关回归系数为0.9885。ANOVA检验证明,在95%置信水平下,所开发的二次模型具有显著性,非常低的P值小于0.05,高的F值为240.1,回归系数接近1。当反应时间为12 min,AP浓度为3.5 mg L-1,电流密度为12 mA cm-2,H2O2用量为86µL时,AP去除率达到99.02%。结论:RSM是一种优化操作条件、最大限度地去除AP的合适方法。在此,EF工艺作为一种环保的电化学高级氧化工艺(EAOP)成功地应用于去除水中和废水中的AP。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Environmental Health and Sustainable Development
Journal of Environmental Health and Sustainable Development Engineering-Engineering (miscellaneous)
CiteScore
1.10
自引率
0.00%
发文量
24
审稿时长
9 weeks
期刊最新文献
Evaluation of Oxidative Stress Induced by Occupational Inhalation Exposure to N2O, an Anesthetic Gas Assessing the Rate of Recyclable Plastic Wastes and Recycling Economic Value in Hospitals of Yazd in 2022 Application of Rodenticides for the Control of Zoonotic Cutaneous Leishmaniasis in Iran: A Systematic Review of the Literature Determining Effective Factors Regarding Weather and Some Types of Air Pollutants in Seasonal Changes of PM10 Concentration Using Tree-Based Algorithms in Yazd City Investigating the Effects of Music and Temperature Changes on Heart Function and Human Error
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1