Multimodal Single-Entity Electrochemical Fluoride Sensor for Fuel Cell Membrane Degradation Diagnostics

R. López, Justin Fuentes, Adrian Gonzalez-Camps, T. Benhaddouch, A. Kaushik, Christopher Lloyd Metler, S. Bhansali, D. Dong
{"title":"Multimodal Single-Entity Electrochemical Fluoride Sensor for Fuel Cell Membrane Degradation Diagnostics","authors":"R. López, Justin Fuentes, Adrian Gonzalez-Camps, T. Benhaddouch, A. Kaushik, Christopher Lloyd Metler, S. Bhansali, D. Dong","doi":"10.1149/2754-2726/ac8aa8","DOIUrl":null,"url":null,"abstract":"To the best of our knowledge, very few works have been done for the continuous real-time monitoring of Proton Exchange Membrane Fuel Cells (PEMFCs) membrane degradation based on fluoride-specific electrochemical microsensors. PEMFCs are eco-smart energy sources for efficient transportation but experience variable degradation rates that wear the Membrane Electrode Assembly (MEA), a critical component of the fuel cell’s functionality. Current market options lack specific diagnostics and a legitimate indication of when exactly the membrane needs to be replaced. As such, this work focused on manufacturing a sensor for measuring MEA degradation in real-time by selectively monitoring fluoride concentration in effluent water, a signature PEMFCs degradation status, through functionalized LaF3:(Au nanoparticle) thin films (∼60 nm). The sensor’s exceptional specificity/sensitivity has been achieved in real-time at a sub 10 ppb level, optimized through spin-coating deposition and post-annealing process. Its multimodal readout has been achieved and studied through the characterizations of open circuit potential, cyclic voltammetry, chronoamperometry, and differential pulse voltammetry revealing a consistent linear decrease of 15.7 mA cm−2 at 0 ppb to 10.2 mA cm−2, while also maintaining its low-cost, small size, and robustness.","PeriodicalId":72870,"journal":{"name":"ECS sensors plus","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECS sensors plus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1149/2754-2726/ac8aa8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

To the best of our knowledge, very few works have been done for the continuous real-time monitoring of Proton Exchange Membrane Fuel Cells (PEMFCs) membrane degradation based on fluoride-specific electrochemical microsensors. PEMFCs are eco-smart energy sources for efficient transportation but experience variable degradation rates that wear the Membrane Electrode Assembly (MEA), a critical component of the fuel cell’s functionality. Current market options lack specific diagnostics and a legitimate indication of when exactly the membrane needs to be replaced. As such, this work focused on manufacturing a sensor for measuring MEA degradation in real-time by selectively monitoring fluoride concentration in effluent water, a signature PEMFCs degradation status, through functionalized LaF3:(Au nanoparticle) thin films (∼60 nm). The sensor’s exceptional specificity/sensitivity has been achieved in real-time at a sub 10 ppb level, optimized through spin-coating deposition and post-annealing process. Its multimodal readout has been achieved and studied through the characterizations of open circuit potential, cyclic voltammetry, chronoamperometry, and differential pulse voltammetry revealing a consistent linear decrease of 15.7 mA cm−2 at 0 ppb to 10.2 mA cm−2, while also maintaining its low-cost, small size, and robustness.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于燃料电池膜降解诊断的多模态单实体电化学氟化物传感器
据我们所知,基于氟化物特异性电化学微传感器对质子交换膜燃料电池(pemfc)膜降解进行持续实时监测的工作很少。pemfc是一种生态智能能源,可用于高效运输,但降解率不同,会磨损膜电极组件(MEA),而膜电极组件是燃料电池功能的关键组成部分。目前的市场选择缺乏具体的诊断和合理的指示,何时需要更换膜。因此,这项工作的重点是制造一种传感器,通过功能化的LaF3:(Au纳米颗粒)薄膜(~ 60 nm),选择性地监测出水中的氟化物浓度,从而实时测量MEA的降解情况。通过旋转镀膜沉积和后退火工艺优化,该传感器在低于10 ppb的水平下实现了卓越的特异性/灵敏度。通过开路电位、循环伏安法、计时伏安法和差分脉冲伏安法的表征,已经实现并研究了它的多模态读数,结果显示,在0 ppb下,它从15.7 mA cm - 2线性下降到10.2 mA cm - 2,同时还保持了它的低成本、小尺寸和鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Portable Dynamic Laser Speckle Imaging for Rapid Antimicrobial Susceptibility Testing. Review—Energy and Power Requirements for Wearable Sensors 3D Printed Carbon Nanotubes Reinforced Polydimethylsiloxane Flexible Sensors for Tactile Sensing Editors’ Choice—Review—Advances in Electrochemical Sensors: Improving Food Safety, Quality, and Traceability Field Testing of a Mixed Potential IoT Sensor Platform for Methane Quantification
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1