A Novel 3D Light Assisted Drawing (3D-LAD) Method to Aid Intraoperative Reproduction of Osteotomy Lines Surrounding a Bone Tumor During Wide Resection: An Experimental Study
Guangyu He, Amos Z. Dai, Vamiq M. Mustahsan, C. Blum, I. Kao, F. Khan
{"title":"A Novel 3D Light Assisted Drawing (3D-LAD) Method to Aid Intraoperative Reproduction of Osteotomy Lines Surrounding a Bone Tumor During Wide Resection: An Experimental Study","authors":"Guangyu He, Amos Z. Dai, Vamiq M. Mustahsan, C. Blum, I. Kao, F. Khan","doi":"10.2147/ORR.S349240","DOIUrl":null,"url":null,"abstract":"Introduction Computer navigation and customized 3D-printed jigs improve accuracy during bone tumor resection, but such technologies can be bulky, costly, and require intraoperative radiation, or long lead time to be ready in OR. Methods We developed a method utilizing a compact, inexpensive, non-X-ray based 3D surface light scanner to provide a visual aid that helps surgeons accurately draw osteotomy lines on the surface of exposed bone to reproduce a well-defined preoperative bone resection plan. We tested the accuracy of the method on 18 sawbones using a distal femur hemimetaphyseal resection model and compared it with a traditional, freehand method. Results The method significantly reduces the positional error from 2.53 (±1.13) mm to 1.04 (±0.43) mm (p<0.001), and angular error of the front angle from 2.10° (±0.83°) to 0.80° (±0.66°) (p=0.001). The method also reduces the mean maximum deviation of the bone resection, with respect to the preoperative path, from 3.75mm to 2.69mm (p=0.003). However, no increased accuracy was observed at the back side of the bone surface where this method would not be expected to provide information. Discussion In summary, we developed a novel 3D-LAD navigation technology. From the experimental study, we demonstrated that the method can improve the ability of surgeons to accurately draw the preoperative osteotomy lines and perform resection of a primary bone sarcoma, with comparison to traditional methods, using 18 sawbones.","PeriodicalId":19608,"journal":{"name":"Orthopedic Research and Reviews","volume":"14 1","pages":"101 - 109"},"PeriodicalIF":1.7000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopedic Research and Reviews","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/ORR.S349240","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction Computer navigation and customized 3D-printed jigs improve accuracy during bone tumor resection, but such technologies can be bulky, costly, and require intraoperative radiation, or long lead time to be ready in OR. Methods We developed a method utilizing a compact, inexpensive, non-X-ray based 3D surface light scanner to provide a visual aid that helps surgeons accurately draw osteotomy lines on the surface of exposed bone to reproduce a well-defined preoperative bone resection plan. We tested the accuracy of the method on 18 sawbones using a distal femur hemimetaphyseal resection model and compared it with a traditional, freehand method. Results The method significantly reduces the positional error from 2.53 (±1.13) mm to 1.04 (±0.43) mm (p<0.001), and angular error of the front angle from 2.10° (±0.83°) to 0.80° (±0.66°) (p=0.001). The method also reduces the mean maximum deviation of the bone resection, with respect to the preoperative path, from 3.75mm to 2.69mm (p=0.003). However, no increased accuracy was observed at the back side of the bone surface where this method would not be expected to provide information. Discussion In summary, we developed a novel 3D-LAD navigation technology. From the experimental study, we demonstrated that the method can improve the ability of surgeons to accurately draw the preoperative osteotomy lines and perform resection of a primary bone sarcoma, with comparison to traditional methods, using 18 sawbones.
期刊介绍:
Orthopedic Research and Reviews is an international, peer-reviewed, open-access journal focusing on the patho-physiology of the musculoskeletal system, trauma, surgery and other corrective interventions to restore mobility and function. Advances in new technologies, materials, techniques and pharmacological agents will be particularly welcome. Specific topics covered in the journal include: Patho-physiology and bioengineering, Technologies and materials science, Surgical techniques, including robotics, Trauma management and care, Treatment including pharmacological and non-pharmacological, Rehabilitation and Multidisciplinarian care approaches, Patient quality of life, satisfaction and preference, Health economic evaluations. The journal welcomes submitted papers covering original research, basic science and technology, clinical studies, reviews and evaluations, guidelines, expert opinion and commentary, case reports and extended reports.