{"title":"Bias-sensitive transparent single-element ultrasound transducers using hot-pressed PMN-PT","authors":"M. Sobhani, K. Latham, Jeremy A. Brown, R. Zemp","doi":"10.1364/osac.426779","DOIUrl":null,"url":null,"abstract":"Here we introduce electrostrictive hot-pressed lead magnesium niobate (PMN) with low lead titanate (PT) doping as a candidate transparent transducer material. We fabricate transparent high-frequency single-element transducers and characterize their optical, electrical, and acoustic properties. PMN-PT may offer sensitivity advantages over other transducer materials such as lithium niobate owing to its high electromechanical efficiency and bias-voltage sensitivity. The transparency of the fabricated transducer was measured ∼67% at 532 nm wavelength with a maximum electromechanical coefficient of ∼0.68 with a DC bias level of 100 V. The photoacoustic impulse response showed a center frequency of ∼27.6 MHz with a −6 dB bandwidth of ∼61% at a DC bias level of 40 V. Results demonstrate that the new transparent transducers hold promise for future optical-ultrasonic and photoacoustic imaging applications.","PeriodicalId":19750,"journal":{"name":"OSA Continuum","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2021-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"OSA Continuum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/osac.426779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 1
Abstract
Here we introduce electrostrictive hot-pressed lead magnesium niobate (PMN) with low lead titanate (PT) doping as a candidate transparent transducer material. We fabricate transparent high-frequency single-element transducers and characterize their optical, electrical, and acoustic properties. PMN-PT may offer sensitivity advantages over other transducer materials such as lithium niobate owing to its high electromechanical efficiency and bias-voltage sensitivity. The transparency of the fabricated transducer was measured ∼67% at 532 nm wavelength with a maximum electromechanical coefficient of ∼0.68 with a DC bias level of 100 V. The photoacoustic impulse response showed a center frequency of ∼27.6 MHz with a −6 dB bandwidth of ∼61% at a DC bias level of 40 V. Results demonstrate that the new transparent transducers hold promise for future optical-ultrasonic and photoacoustic imaging applications.