E. Mesquita, Francisco Da Silva Brandão, Aldecira G. Diogenes, P. Antunes, H. Varum
{"title":"Ambient vibrational characterization of the Nossa Senhora das Dores Church","authors":"E. Mesquita, Francisco Da Silva Brandão, Aldecira G. Diogenes, P. Antunes, H. Varum","doi":"10.3846/2029882X.2017.1416311","DOIUrl":null,"url":null,"abstract":"The present paper shows the vibrational characterization tests of a clay brick heritage construction from XIX century, the Nossa Senhora das Dores Church, placed in Sobral, Brazil. In this study the calibration of the 3D finite element numerical model of the church was performed through ambient vibrational testing using the first three natural frequencies identified. The obtained results, namely the natural frequencies identified, and the calibrated model intends to give a contribute for understanding of the structural behavior of the Brazilian heritage constructions, and introduces relevant information for be used for safety assessment of the church along the time.","PeriodicalId":11839,"journal":{"name":"Engineering Structures and Technologies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3846/2029882X.2017.1416311","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering Structures and Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3846/2029882X.2017.1416311","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
The present paper shows the vibrational characterization tests of a clay brick heritage construction from XIX century, the Nossa Senhora das Dores Church, placed in Sobral, Brazil. In this study the calibration of the 3D finite element numerical model of the church was performed through ambient vibrational testing using the first three natural frequencies identified. The obtained results, namely the natural frequencies identified, and the calibrated model intends to give a contribute for understanding of the structural behavior of the Brazilian heritage constructions, and introduces relevant information for be used for safety assessment of the church along the time.
本文展示了19世纪巴西索布拉尔的Nossa Senhora das Dores教堂的粘土砖遗产建筑的振动特性测试。在这项研究中,通过使用确定的前三个固有频率进行环境振动测试,对教堂的三维有限元数值模型进行了校准。所获得的结果,即确定的固有频率,以及校准的模型旨在为理解巴西遗产建筑的结构行为做出贡献,并为教堂的安全评估提供相关信息。