Importance of taking into account the thermal mass in simulations for a non-air-conditioned house

Guadalupe Huelsz Lesbros, Gabriela Álvarez Almeida, Jorge Rojas Menéndez, Guillermo Barrios del Valle
{"title":"Importance of taking into account the thermal mass in simulations for a non-air-conditioned house","authors":"Guadalupe Huelsz Lesbros, Gabriela Álvarez Almeida, Jorge Rojas Menéndez, Guillermo Barrios del Valle","doi":"10.22201/fi.25940732e.2022.23.3.024","DOIUrl":null,"url":null,"abstract":"Building thermal simulation (BTS) programs are being increasingly used to evaluate the occupants’ thermal comfort and the building’s energy consumption. Although some authors have pointed out that not taking into account the thermal mass of the building’s components results in erroneous performance predictions, some BTS program users, standards and building rating systems still do not consider the thermal mass. The quantification of the difference in the simulations’ predictions of the performance of a building when its thermal mass is either considered (M) or ignored (NM) have been reported in the literature for air-conditioned buildings (AC). In this work, and for the first time, the quantification is made for a non-air-conditioned (nAC) building. The quantification of the difference between M and NM simulations’ results is also made for the same building but with AC. Simulations were carried out using EnergyPlus and considering four study cases according to the constructive systems of walls and roofs. The building is a house located in a Mexican city with a hot summer and a mild winter. For the nAC house the differences in monthly averages for the daily maximum and for the daily minimum temperatures between M and NM simulations are up to 8.3oC and 6.4oC respectively, and differences for the cold and hot discomfort degree hours are up to 124%. For the AC house the differences between M and NM simulations on the cooling and heating thermal loads are up to 30%. The difference in the air conditioning peak power demand is up to 38%, and the difference in the time this peak occurs is up to 4 hours. These results show that differences between simulations are larger for the nAC house than they are for the AC house.","PeriodicalId":30321,"journal":{"name":"Ingenieria Investigacion y Tecnologia","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ingenieria Investigacion y Tecnologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22201/fi.25940732e.2022.23.3.024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Building thermal simulation (BTS) programs are being increasingly used to evaluate the occupants’ thermal comfort and the building’s energy consumption. Although some authors have pointed out that not taking into account the thermal mass of the building’s components results in erroneous performance predictions, some BTS program users, standards and building rating systems still do not consider the thermal mass. The quantification of the difference in the simulations’ predictions of the performance of a building when its thermal mass is either considered (M) or ignored (NM) have been reported in the literature for air-conditioned buildings (AC). In this work, and for the first time, the quantification is made for a non-air-conditioned (nAC) building. The quantification of the difference between M and NM simulations’ results is also made for the same building but with AC. Simulations were carried out using EnergyPlus and considering four study cases according to the constructive systems of walls and roofs. The building is a house located in a Mexican city with a hot summer and a mild winter. For the nAC house the differences in monthly averages for the daily maximum and for the daily minimum temperatures between M and NM simulations are up to 8.3oC and 6.4oC respectively, and differences for the cold and hot discomfort degree hours are up to 124%. For the AC house the differences between M and NM simulations on the cooling and heating thermal loads are up to 30%. The difference in the air conditioning peak power demand is up to 38%, and the difference in the time this peak occurs is up to 4 hours. These results show that differences between simulations are larger for the nAC house than they are for the AC house.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在模拟非空调房屋时考虑热质量的重要性
建筑热模拟(BTS)程序越来越多地用于评估居住者的热舒适性和建筑的能耗。尽管一些作者指出,不考虑建筑组件的热质量会导致错误的性能预测,但一些BTS项目用户、标准和建筑评级系统仍然没有考虑热质量。空调建筑(AC)的文献中已经报道了当考虑(M)或忽略(NM)热质量时,模拟对建筑性能预测的差异的量化。在这项工作中,首次对非空调(nAC)建筑进行了量化。M和NM模拟结果之间的差异的量化也适用于同一栋建筑,但使用AC。模拟是使用EnergyPlus进行的,并根据墙壁和屋顶的构造系统考虑了四个研究案例。这座建筑是一座位于墨西哥城市的房子,夏天炎热,冬天温和。对于国家航空航天局来说,模拟M和NM之间的日最高温度和日最低温度的月平均值差异分别高达8.3摄氏度和6.4摄氏度,冷热不适度小时的差异高达124%。对于AC房屋,M和NM模拟在制冷和制热负荷方面的差异高达30%。空调峰值功率需求的差异高达38%,该峰值出现的时间差异高达4小时。这些结果表明,与AC房屋相比,nAC房屋的模拟之间的差异更大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
18
审稿时长
52 weeks
期刊最新文献
Analytical formula of the mutual impedance of a partial core transformer with conductive tapes Análisis del sistema de medición por atributos en la inspección de calidad para zarzamoras Application of mass-balance method to evaluate recharge rate patterns in a Quaternary aquifer in northern Mexico Mineragraphic evaluation for gold recovery Prediseño de una red de drenaje pluvial urbana con algoritmos genéticos
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1