Posterior Minimally Invasive Plate Osteosynthesis of Humeral Shaft Fractures: An Anatomic Study of “Danger Zones”

IF 4.5 Q1 EDUCATION & EDUCATIONAL RESEARCH Techniques in Shoulder and Elbow Surgery Pub Date : 2020-05-08 DOI:10.1097/BTE.0000000000000189
Kelsey A. Rebehn, Lisa K. Cannada, J. Watson
{"title":"Posterior Minimally Invasive Plate Osteosynthesis of Humeral Shaft Fractures: An Anatomic Study of “Danger Zones”","authors":"Kelsey A. Rebehn, Lisa K. Cannada, J. Watson","doi":"10.1097/BTE.0000000000000189","DOIUrl":null,"url":null,"abstract":"The most utilized approach for minimally invasive plate osteosynthesis (MIPO) of humeral fractures has been an anterior percutaneous approach. Other approaches include posterior, which places the radial nerve at risk. We performed a cadaveric study to evaluate safe intervals for screw placement using a posterior approach. MIPO fixation of the humeral shaft was performed on 11 fresh frozen cadaveric specimens following a standard protocol using a 10-hole 4.5 locking compression plate (LCP) plate and cortical screws. After fixation, anatomic dissection of the radial nerve was performed and location of the nerve delineated with regards to radiographic landmarks and the fixation construct. A 10-hole LCP plate centered on the humerus will position a screw in the third hole from top of plate only 3.08 cm (±SD 1.05 cm) from the radial nerve. The distal screws in the LCP plate construct do not the place the radial nerve at risk. The literature reports rates of iatrogenic radial nerve injury during formal open reduction and internal fixation approaching 20%, and during MIPO between 0% and 5%. With a posterior MIPO approach the radial nerve is most at risk with screw placement in the fifth and sixth holes from the top of a 10-hole plate.","PeriodicalId":44224,"journal":{"name":"Techniques in Shoulder and Elbow Surgery","volume":"21 1","pages":"50 - 53"},"PeriodicalIF":4.5000,"publicationDate":"2020-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/BTE.0000000000000189","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Shoulder and Elbow Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BTE.0000000000000189","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"EDUCATION & EDUCATIONAL RESEARCH","Score":null,"Total":0}
引用次数: 0

Abstract

The most utilized approach for minimally invasive plate osteosynthesis (MIPO) of humeral fractures has been an anterior percutaneous approach. Other approaches include posterior, which places the radial nerve at risk. We performed a cadaveric study to evaluate safe intervals for screw placement using a posterior approach. MIPO fixation of the humeral shaft was performed on 11 fresh frozen cadaveric specimens following a standard protocol using a 10-hole 4.5 locking compression plate (LCP) plate and cortical screws. After fixation, anatomic dissection of the radial nerve was performed and location of the nerve delineated with regards to radiographic landmarks and the fixation construct. A 10-hole LCP plate centered on the humerus will position a screw in the third hole from top of plate only 3.08 cm (±SD 1.05 cm) from the radial nerve. The distal screws in the LCP plate construct do not the place the radial nerve at risk. The literature reports rates of iatrogenic radial nerve injury during formal open reduction and internal fixation approaching 20%, and during MIPO between 0% and 5%. With a posterior MIPO approach the radial nerve is most at risk with screw placement in the fifth and sixth holes from the top of a 10-hole plate.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肱骨干骨折后微创钢板内固定术“危险区”的解剖学研究
肱骨骨折微创钢板接骨术(MIPO)最常用的方法是前路经皮入路。其他方法包括后神经,这会使桡神经处于危险之中。我们进行了一项尸体研究,以评估使用后部入路放置螺钉的安全间隔。根据标准方案,使用10孔4.5锁定加压钢板(LCP)和皮质螺钉在11个新鲜冷冻尸体标本上进行肱骨干的MIPO固定。固定后,对桡神经进行解剖解剖,并根据放射学标志和固定结构确定神经位置。以肱骨为中心的10孔LCP钢板将螺钉定位在钢板顶部的第三个孔中,仅3.08 cm(±SD 1.05 cm)。LCP板结构中的远端螺钉不会使桡神经处于危险之中。文献报道,在正式切开复位和内固定期间,医源性桡神经损伤的发生率接近20%,在MIPO期间,发生率在0%至5%之间。对于后部MIPO入路,将螺钉放置在10孔板顶部的第五和第六孔中,桡神经的风险最大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊介绍: Published quarterly, Techniques in Shoulder & Elbow Surgery escorts the reader into the operating room and supplies step-by-step details of exciting and advanced techniques. It explains the evolution of and rationale for the procedures, identifies the pitfalls and possible complications, provides invaluable tips for improving surgical results and it is illustrated cover to cover with high-quality intraoperative photographs and drawings, many in full color.
期刊最新文献
Lateral Epicondylitis Intramedullary Screw Fixation Supplemented by Scapular Spine Plating: A Surgical Technique for the Base of Acromion Fracture Small Fragment Instrumentation for Periprosthetic Humerus Fracture Fixation Technique A Simplified Technique for Patient Positioning During Olecranon Fracture Fixation Lateralized Versus Nonlateralized Reverse Shoulder Arthroplasty: Impact on Clinical and Functional Outcomes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1