Electrical Indication of Modified Concrete´s and Mortar´s Ability Resist Chloride Ion Penetration

IF 0.1 Q4 ENGINEERING, MULTIDISCIPLINARY Revista Digital Lampsakos Pub Date : 2018-07-10 DOI:10.21501/21454086.2358
Luz Marina Torrado-Gómez, Norma Cristina Solarte-Vanegas
{"title":"Electrical Indication of Modified Concrete´s and Mortar´s Ability Resist Chloride Ion Penetration","authors":"Luz Marina Torrado-Gómez, Norma Cristina Solarte-Vanegas","doi":"10.21501/21454086.2358","DOIUrl":null,"url":null,"abstract":"This article describes the ability of concrete and mortar mixtures with different fly ash contents to resist chloride ion penetration 14 and 28 days after casting. The Rapid Chloride Permeability Test (RCPT) in accordance to the norm ASTM C1202 was used in order to obtain qualitative indications of the chloride ion penetrability depending on the electrical conductance of concrete respectively mortar samples. Furthermore, the Automatic Concrete Water Permeability Apparatus at Four Cells C430X from Matest was used to measure the water permeability 28 days after casting. Finally, the uniaxial compressive strength was measured 28 days after casting. The following conclusions can be made. The results of the Chloride Permeability Test (RCPT) did not show a clear correlation between the ash content, the a/c ratio and the Chloride Ion Penetrability. However, the chloride diffusion coefficient for the hormone and mortar at 28 days tends to increase with increasing a / c ratio and decreases with the age of hydration. As for permeability, an increase in the permeability was found at 28 days of age with an increasing ratio of a/c ratio.","PeriodicalId":53826,"journal":{"name":"Revista Digital Lampsakos","volume":" ","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2018-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Digital Lampsakos","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21501/21454086.2358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1

Abstract

This article describes the ability of concrete and mortar mixtures with different fly ash contents to resist chloride ion penetration 14 and 28 days after casting. The Rapid Chloride Permeability Test (RCPT) in accordance to the norm ASTM C1202 was used in order to obtain qualitative indications of the chloride ion penetrability depending on the electrical conductance of concrete respectively mortar samples. Furthermore, the Automatic Concrete Water Permeability Apparatus at Four Cells C430X from Matest was used to measure the water permeability 28 days after casting. Finally, the uniaxial compressive strength was measured 28 days after casting. The following conclusions can be made. The results of the Chloride Permeability Test (RCPT) did not show a clear correlation between the ash content, the a/c ratio and the Chloride Ion Penetrability. However, the chloride diffusion coefficient for the hormone and mortar at 28 days tends to increase with increasing a / c ratio and decreases with the age of hydration. As for permeability, an increase in the permeability was found at 28 days of age with an increasing ratio of a/c ratio.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
改性混凝土和砂浆抗氯离子渗透性能的电气指标
本文介绍了不同粉煤灰含量的混凝土和砂浆混合物在浇筑后14天和28天抵抗氯离子渗透的能力。使用根据标准ASTM C1202的快速氯离子渗透性测试(RCPT),以获得取决于混凝土和砂浆样品的电导率的氯离子渗透能力的定性指示。此外,使用来自Matest的四孔C430X的自动混凝土透水性装置来测量浇筑后28天的透水性。最后,在铸造后28天测量单轴抗压强度。可以得出以下结论。氯化物渗透性试验(RCPT)的结果没有显示灰分、a/c比和氯离子渗透性之间的明显相关性。然而,激素和砂浆在28天时的氯离子扩散系数往往随着a/c比的增加而增加,并随着水化年龄的增加而降低。关于渗透率,在28天龄时发现渗透率随着a/c比的增加而增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Revista Digital Lampsakos
Revista Digital Lampsakos ENGINEERING, MULTIDISCIPLINARY-
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊最新文献
Métodos de Clapeyron y Cross para el análisis de vigas de inercia variable Ceramic waste in semi-dense asphalt mixtures: alternatives for low traffic roads in Colombia Manejo de residuos de construcción y demolición y economía circular: una revisión narrativa Conceptualización de resiliencia al cambio climático en cadenas agropecuarias de valor Desarrollo de un modelo predictivo de las propiedades mecánicas del suelo usando redes neuronales artificiales
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1