{"title":"Utility of <sup>99m</sup>Tc-Sulfur Colloid Lymphoscintigraphy and SPECT/CT in Chylothorax and Chylous Ascites.","authors":"Jasim Jaleel, Syeddharvesh Nasurudeen, Anushna Sunila Babu, Priyanka Gupta, Bangkim Chandra Khangembam, Chetan Patel, Rakesh Kumar","doi":"10.1007/s13139-023-00813-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the diagnostic efficacy of <sup>99m</sup>Tc-sulfur colloid lymphoscintigraphy in chylothorax and chylous ascites, and the utility of single-photon emission computed tomography-computed tomography (SPECT/CT) in localizing the sites of leaks.</p><p><strong>Methods: </strong>Data from patients who underwent lymphoscintigraphy for clinical suspicion of chylothorax or chylous ascites were retrospectively analyzed. Biochemical fluid analysis was taken as the reference standard. Pleural fluid triglyceride level > 110 mg/dL (with pleural fluid/serum ratio > 1) and a cholesterol level < 200 mg/dL (with pleural fluid/serum ratio < 1) were considered confirmatory for chylothorax. Ascitic fluid triglyceride level > 200 mg/dL with a low cholesterol level (ascites fluid/serum ratio < 1) was considered confirmatory for chylous ascites.</p><p><strong>Results: </strong>26 patients (15 males, 57.7%) aged 9 months to 68 years were enrolled in the study. Based on the reference standard, 17 had chylothorax or chylous ascites (9 with surgical history). Lymphoscintigraphy was positive in 16 (with 1 false positive) and negative in 10 (with 2 false negatives). The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy of lymphoscintigraphy were 88.2% (63.6-98.5%), 88.9% (51.8-99.7%), 80.0% (51.6-93.8%), 93.8% (70.1-99.0%), and 88.5% (69.9-97.6%), respectively. SPECT/CT could localize sites of leaks in 61.5% (8/13) with a localization rate of 77.8% (7/9) and 25.0% (1/4) in patients with surgical and nonsurgical causes, respectively.</p><p><strong>Conclusion: </strong><sup>99m</sup>Tc-sulfur colloid lymphoscintigraphy is a highly efficacious noninvasive modality to diagnose chylothorax or chylous ascites with a high positive predictive value. SPECT/CT could localize the sites of leaks more frequently in patients with surgical causes.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":" ","pages":"265-274"},"PeriodicalIF":17.7000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10654269/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s13139-023-00813-6","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To assess the diagnostic efficacy of 99mTc-sulfur colloid lymphoscintigraphy in chylothorax and chylous ascites, and the utility of single-photon emission computed tomography-computed tomography (SPECT/CT) in localizing the sites of leaks.
Methods: Data from patients who underwent lymphoscintigraphy for clinical suspicion of chylothorax or chylous ascites were retrospectively analyzed. Biochemical fluid analysis was taken as the reference standard. Pleural fluid triglyceride level > 110 mg/dL (with pleural fluid/serum ratio > 1) and a cholesterol level < 200 mg/dL (with pleural fluid/serum ratio < 1) were considered confirmatory for chylothorax. Ascitic fluid triglyceride level > 200 mg/dL with a low cholesterol level (ascites fluid/serum ratio < 1) was considered confirmatory for chylous ascites.
Results: 26 patients (15 males, 57.7%) aged 9 months to 68 years were enrolled in the study. Based on the reference standard, 17 had chylothorax or chylous ascites (9 with surgical history). Lymphoscintigraphy was positive in 16 (with 1 false positive) and negative in 10 (with 2 false negatives). The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy of lymphoscintigraphy were 88.2% (63.6-98.5%), 88.9% (51.8-99.7%), 80.0% (51.6-93.8%), 93.8% (70.1-99.0%), and 88.5% (69.9-97.6%), respectively. SPECT/CT could localize sites of leaks in 61.5% (8/13) with a localization rate of 77.8% (7/9) and 25.0% (1/4) in patients with surgical and nonsurgical causes, respectively.
Conclusion: 99mTc-sulfur colloid lymphoscintigraphy is a highly efficacious noninvasive modality to diagnose chylothorax or chylous ascites with a high positive predictive value. SPECT/CT could localize the sites of leaks more frequently in patients with surgical causes.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.