Occurrence and removal of microplastics in a municipal wastewater treatment plant with conventional activated sludge process: A case study in Isfahan, Iran

IF 1.3 Q4 ENVIRONMENTAL SCIENCES Environmental Health Engineering and Management Journal Pub Date : 2023-02-01 DOI:10.34172/ehem.2023.07
H. Sharifi, H. Movahedian Attar, B. Bina
{"title":"Occurrence and removal of microplastics in a municipal wastewater treatment plant with conventional activated sludge process: A case study in Isfahan, Iran","authors":"H. Sharifi, H. Movahedian Attar, B. Bina","doi":"10.34172/ehem.2023.07","DOIUrl":null,"url":null,"abstract":"Background: Microplastics (MPs) are nowadays found in the air and in various terrestrial and aquatic environments and have become emerging pollutants. These particles can absorb other chemicals and microbial contaminants and release them into the environment and food chain. Despite the high efficiency of wastewater treatment plants (WWTPs) in removing MPs, WWTPs are still one of the major sources of MPs discharge to the environment. This study was conducted to evaluate the efficiency of MPs removal in a municipal WWTP with conventional activated sludge in Iran. Methods: MPs particles were counted using a stereomicroscope after the initial preparation steps (sieving, chemical digestion with the catalytic wet peroxidation-oxidation and density separation with NaCl) and then analyzed for particle composition using a Raman micro-spectrometer. Results: MPs concentration in the influent, grit chamber, primary sedimentation tank, and effluent were 843.2±147.5, 315.5±54.7, 80.2±19.1, and 11.13±3.14 items/L, respectively. The overall MPs removal efficiency of the WWTP was 98.7%, with the grit chamber, primary sedimentation tank, and secondary sedimentation tank removed 62.6%, 27.9%, and 8.2% of the total MPs, respectively. The most abundant polymers were polypropylene (PP) and polyethylene (PE). Conclusion: Despite the effective removal of MPs in WWTP, on average 4.47×1011±1.03×1011 MPs are discharged into the receiving waters through the effluent of this WWTP annually. This means that WWTPs can be one of the major sources of MPs in the environment and efforts should be made to increase the efficiency of WWTPs and equip them with advanced technologies.","PeriodicalId":51877,"journal":{"name":"Environmental Health Engineering and Management Journal","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Health Engineering and Management Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/ehem.2023.07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Microplastics (MPs) are nowadays found in the air and in various terrestrial and aquatic environments and have become emerging pollutants. These particles can absorb other chemicals and microbial contaminants and release them into the environment and food chain. Despite the high efficiency of wastewater treatment plants (WWTPs) in removing MPs, WWTPs are still one of the major sources of MPs discharge to the environment. This study was conducted to evaluate the efficiency of MPs removal in a municipal WWTP with conventional activated sludge in Iran. Methods: MPs particles were counted using a stereomicroscope after the initial preparation steps (sieving, chemical digestion with the catalytic wet peroxidation-oxidation and density separation with NaCl) and then analyzed for particle composition using a Raman micro-spectrometer. Results: MPs concentration in the influent, grit chamber, primary sedimentation tank, and effluent were 843.2±147.5, 315.5±54.7, 80.2±19.1, and 11.13±3.14 items/L, respectively. The overall MPs removal efficiency of the WWTP was 98.7%, with the grit chamber, primary sedimentation tank, and secondary sedimentation tank removed 62.6%, 27.9%, and 8.2% of the total MPs, respectively. The most abundant polymers were polypropylene (PP) and polyethylene (PE). Conclusion: Despite the effective removal of MPs in WWTP, on average 4.47×1011±1.03×1011 MPs are discharged into the receiving waters through the effluent of this WWTP annually. This means that WWTPs can be one of the major sources of MPs in the environment and efforts should be made to increase the efficiency of WWTPs and equip them with advanced technologies.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用常规活性污泥法的城市污水处理厂微塑料的发生和去除:伊朗伊斯法罕的案例研究
背景:微塑料(MP)目前存在于空气、各种陆地和水生环境中,已成为新出现的污染物。这些颗粒可以吸收其他化学物质和微生物污染物,并将其释放到环境和食物链中。尽管污水处理厂在去除MP方面效率很高,但污水处理厂仍然是MP排放到环境中的主要来源之一。本研究旨在评估伊朗城市污水处理厂使用传统活性污泥去除MPs的效率。方法:在初始制备步骤(筛选、催化湿式过氧化化学消化和NaCl密度分离)后,使用立体显微镜对MPs颗粒进行计数,然后使用拉曼光谱仪分析颗粒组成。结果:进水、沉砂池、初沉池和出水的MPs浓度分别为843.2±147.5、315.5±54.7、80.2±19.1和11.13±3.14项/L。污水处理厂的总MPs去除率为98.7%,沉砂池、初沉池和二沉池分别去除了62.6%、27.9%和8.2%的MPs。最丰富的聚合物是聚丙烯(PP)和聚乙烯(PE)。结论:尽管污水处理厂能有效去除污水中的MPs,但该污水处理厂每年平均有4.47×1011±1.03×1011个MPs通过污水排入受纳水体。这意味着污水处理厂可能是环境中MP的主要来源之一,应努力提高污水处理厂的效率并为其配备先进技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.40
自引率
37.50%
发文量
17
审稿时长
12 weeks
期刊最新文献
Two phases of online food delivery app users’ behavior in Greater Jakarta during the second year of the COVID-19 pandemic: Perceptions of food safety and hygiene Feasibility of natural wastewater treatment systems and life cycle assessment (LCA) for aquatic systems Modeling the concentration of suspended particles by fuzzy inference system (FIS) and adaptive neuro-fuzzy inference system (ANFIS) techniques: A case study in the metro stations Plant inoculation with Piriformospora indica fungus and additive effects of organic and inorganic Zn fertilize on decreasing the Cd concentration of the plants cultivated in the Cd-polluted soil Quantitative assessment of health, safety, and environment (HSE) resilience based on the Delphi method and analytic hierarchy process (AHP) in municipal solid waste management system: A case study in Tehran
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1