Validation of the Korean Version of the Depression in Old Age Scale and Comparison with Other Depression Screening Questionnaires Used in Elderly Patients in Medical Settings
Young-Eun Jung, Moon-Doo Kim, W. Bahk, Y. Woo, Beomwoo Nam, J. Seo, Sae-Heon Jang, H. Sung, I. Shim, B. Yoon, Ji Sun Kim, Y. Kwon
{"title":"Validation of the Korean Version of the Depression in Old Age Scale and Comparison with Other Depression Screening Questionnaires Used in Elderly Patients in Medical Settings","authors":"Young-Eun Jung, Moon-Doo Kim, W. Bahk, Y. Woo, Beomwoo Nam, J. Seo, Sae-Heon Jang, H. Sung, I. Shim, B. Yoon, Ji Sun Kim, Y. Kwon","doi":"10.9758/cpn.2019.17.3.369","DOIUrl":null,"url":null,"abstract":"Objective The Depression in Old Age Scale (DIA-S) is a new screening tool for assessing depression in the elderly. The primary aims of this study were to describe the validation of the Korean version of the DIA-S (K-DIA-S) and to compare its validity with that of other depression screening questionnaires used in elderly outpatients in medical settings. Methods A total of 385 elderly outpatients completed the K-DIA-S and underwent the Mini International Neuropsychiatric Interview to diagnose depressive disorders. Other measures included the 15-item short form of the Geriatric Depression Scale (SGDS), the 9-item depression module of the Patient Health Questionnaire (PHQ-9), and the Montgomery–Asberg Depression Rating Scale (MADRS). Reliability and validity tests, an optimal cutoff point estimate, and receiver operating characteristic curve analysis were performed to investigate the diagnostic validity of the K-DIA-S. Areas under the curves (AUCs) for the K-DIA-S, SGDS, and PHQ-9 were compared statistically. Results The K-DIA-S showed good internal consistency and strong correlations with the SGDS (r = 0.853), PHQ-9 (r = 0.739), and MADRS (r = 0.772). The cut-off point of the K-DIA-S that can be recommended for screening depressive symptoms was a score of 4. For “any depressive disorder”, the AUC (standard error) for the K-DIA-S was 0.896 (0.015), which was significantly larger than that for the PHQ-9 (p = 0.033). Conclusion The present findings suggest that the K-DIA-S has good psychometric properties and is a valid and reliable tool for assessing depressive symptoms in elderly populations and medically ill patients.","PeriodicalId":10420,"journal":{"name":"Clinical Psychopharmacology and Neuroscience","volume":"17 1","pages":"369 - 376"},"PeriodicalIF":2.4000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Psychopharmacology and Neuroscience","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.9758/cpn.2019.17.3.369","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 4
Abstract
Objective The Depression in Old Age Scale (DIA-S) is a new screening tool for assessing depression in the elderly. The primary aims of this study were to describe the validation of the Korean version of the DIA-S (K-DIA-S) and to compare its validity with that of other depression screening questionnaires used in elderly outpatients in medical settings. Methods A total of 385 elderly outpatients completed the K-DIA-S and underwent the Mini International Neuropsychiatric Interview to diagnose depressive disorders. Other measures included the 15-item short form of the Geriatric Depression Scale (SGDS), the 9-item depression module of the Patient Health Questionnaire (PHQ-9), and the Montgomery–Asberg Depression Rating Scale (MADRS). Reliability and validity tests, an optimal cutoff point estimate, and receiver operating characteristic curve analysis were performed to investigate the diagnostic validity of the K-DIA-S. Areas under the curves (AUCs) for the K-DIA-S, SGDS, and PHQ-9 were compared statistically. Results The K-DIA-S showed good internal consistency and strong correlations with the SGDS (r = 0.853), PHQ-9 (r = 0.739), and MADRS (r = 0.772). The cut-off point of the K-DIA-S that can be recommended for screening depressive symptoms was a score of 4. For “any depressive disorder”, the AUC (standard error) for the K-DIA-S was 0.896 (0.015), which was significantly larger than that for the PHQ-9 (p = 0.033). Conclusion The present findings suggest that the K-DIA-S has good psychometric properties and is a valid and reliable tool for assessing depressive symptoms in elderly populations and medically ill patients.
期刊介绍:
Clinical Psychopharmacology and Neuroscience (Clin Psychopharmacol Neurosci) launched in 2003, is the official journal of The Korean College of Neuropsychopharmacology (KCNP), and the associate journal for Asian College of Neuropsychopharmacology (AsCNP). This journal aims to publish evidence-based, scientifically written articles related to clinical and preclinical studies in the field of psychopharmacology and neuroscience. This journal intends to foster and encourage communications between psychiatrist, neuroscientist and all related experts in Asia as well as worldwide. It is published four times a year at the last day of February, May, August, and November.