The Roles of Microprobe in Localized Electrodeposition: Electrolyte Localized Transport and Force-Displacement Sensitivity.

IF 4.7 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-04-01 Epub Date: 2024-04-16 DOI:10.1089/3dp.2022.0238
Wanfei Ren, Manfei Wang, Xiaoqing Sun, Edgar Hepp, Jinkai Xu
{"title":"The Roles of Microprobe in Localized Electrodeposition: Electrolyte Localized Transport and Force-Displacement Sensitivity.","authors":"Wanfei Ren, Manfei Wang, Xiaoqing Sun, Edgar Hepp, Jinkai Xu","doi":"10.1089/3dp.2022.0238","DOIUrl":null,"url":null,"abstract":"<p><p>Facing the rapid development of 6G communication, long-wave infrared metasurface and biomimetic microfluidics, the performance requirements for microsystems based on metal tiny structures are gradually increasing. As one of powerful methods for fabrication metal complex microstructures, localized electrochemical deposition microadditive manufacturing technology can fabricate copper metal micro overhanging structures without masks and supporting materials. In this study, the role of the microprobe cantilever (MC) in localized electrodeposition was studied. The MC can be used for precise deposition with electrolyte localized transport function and high accuracy force-displacement sensitivity. To prove this, the electrolyte flow was simulated when the MC was in bending or normal state. The simulation results can indicate the influence of turbulent flow on the electrolyte flow velocity and the pressure at the end of the pyramid. The results show that the internal flow velocity increased by 8.9% in the bending probe as compared with normal. Besides, this study analyzed the force-potential sensitivity characteristics of the MC. Using the deformation of the MC as an intermediate variable, the model of the probe tip displacement caused by the growth of the deposit and the voltage value displayed by the photodetector was mathematically established. In addition, the deposition of a single voxel was simulated by simulation process with the simulated height of 520 nm for one voxel, and the coincidence of simulation and experimental results was 93.1%. In conclusion, this method provides a new way for localized electrodeposition of complex microstructures.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"e743-e750"},"PeriodicalIF":4.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11058414/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/3dp.2022.0238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Facing the rapid development of 6G communication, long-wave infrared metasurface and biomimetic microfluidics, the performance requirements for microsystems based on metal tiny structures are gradually increasing. As one of powerful methods for fabrication metal complex microstructures, localized electrochemical deposition microadditive manufacturing technology can fabricate copper metal micro overhanging structures without masks and supporting materials. In this study, the role of the microprobe cantilever (MC) in localized electrodeposition was studied. The MC can be used for precise deposition with electrolyte localized transport function and high accuracy force-displacement sensitivity. To prove this, the electrolyte flow was simulated when the MC was in bending or normal state. The simulation results can indicate the influence of turbulent flow on the electrolyte flow velocity and the pressure at the end of the pyramid. The results show that the internal flow velocity increased by 8.9% in the bending probe as compared with normal. Besides, this study analyzed the force-potential sensitivity characteristics of the MC. Using the deformation of the MC as an intermediate variable, the model of the probe tip displacement caused by the growth of the deposit and the voltage value displayed by the photodetector was mathematically established. In addition, the deposition of a single voxel was simulated by simulation process with the simulated height of 520 nm for one voxel, and the coincidence of simulation and experimental results was 93.1%. In conclusion, this method provides a new way for localized electrodeposition of complex microstructures.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
微探针在局部电沉积中的作用:电解质的局部输运和力位移灵敏度
面对 6G 通信、长波红外超表面和仿生微流控技术的快速发展,对基于金属微小结构的微系统的性能要求逐渐提高。局部电化学沉积微添加制造技术作为制造金属复杂微结构的有力手段之一,可以在不使用掩膜和支撑材料的情况下制造出铜金属微悬浮结构。本研究对微探针悬臂(MC)在局部电沉积中的作用进行了研究。MC 可用于精确沉积,具有电解质局部传输功能和高精度的力-位移灵敏度。为了证明这一点,模拟了 MC 处于弯曲或正常状态时的电解质流动。模拟结果表明了湍流对电解质流速和金字塔末端压力的影响。结果表明,与正常状态相比,弯曲探头的内部流速增加了 8.9%。此外,本研究还分析了 MC 的力-电位灵敏度特性。以 MC 的变形为中间变量,用数学方法建立了沉积物生长引起的探针尖端位移和光电探测器显示的电压值模型。此外,还通过仿真过程模拟了单个体素的沉积,模拟高度为单个体素 520 nm,仿真结果与实验结果的吻合度为 93.1%。总之,这种方法为复杂微结构的局部电沉积提供了一种新的途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊介绍: ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.
期刊最新文献
Broad-Spectrum Light-Activated Synergistic Antibacterial Platform Based on an Azobenzene-Quaternary Ammonium@MXene Nanocomposite. Divergence in Cu(II)- and Zn(II)-Based Coordination Polymers: The Sensing of Melatonin and Tryptophan, and Their Anticancer Activity. The Corrosion Resistance and Biocompatibility of the Magnetron Sputtered Si Film. Microfluidic Based In Situ Synthesis of Magneto-Responsive Microcarrier Hydrogel Bead and its Cell Seeding Applications. Lotus-Leaf-Extract-Based Nanoformulation for Sensitive Skin: Whitening and Barrier-Supporting Properties.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1