Smart handheld medical device with patient-specific force regulation mechanism

IF 1.9 4区 计算机科学 Q3 AUTOMATION & CONTROL SYSTEMS Assembly Automation Pub Date : 2022-04-12 DOI:10.1108/aa-10-2021-0126
Zhuoqi Cheng, Jiale He, Pengjie Lin, Min He, Jing Guo, Xinwei Chen, Shuting Cai, Xiaoming Xiong
{"title":"Smart handheld medical device with patient-specific force regulation mechanism","authors":"Zhuoqi Cheng, Jiale He, Pengjie Lin, Min He, Jing Guo, Xinwei Chen, Shuting Cai, Xiaoming Xiong","doi":"10.1108/aa-10-2021-0126","DOIUrl":null,"url":null,"abstract":"\nPurpose\nThe purpose of this paper is to design a smart handheld device with force regulating function, which demonstrates the concept of patient-specialized tools.\n\n\nDesign/methodology/approach\nThis handheld device integrates an electrical bioimpedance (EBI) sensor for tissue measurement and a constant force regulation mechanism for ensuring stable tool–tissue contact. Particular focuses in this study are on the design of the constant force regulation mechanism whose design process is through genetic algorithm optimization and finite element simulation. In addition, the output force can be changed to the desired value by adjusting the cross-sectional area of the generated spring.\n\n\nFindings\nThe following two specific applications based on ex vivo tissues are used for evaluating the designed device. One is in terms of safety of interaction with delicate tissue while the other is for compensating involuntary tissue motion. The results of both examples show that the handheld device is able to provide an output force with a small standard deviation.\n\n\nOriginality/value\nIn this paper, a handheld device with force regulation mechanism is designed for specific patients based on the genetic algorithm optimization and finite element simulation. The device can maintain a steady and safe interaction force during the EBI measurement on fragile tissues or moving tissues, to improve the sensing accuracy and to avoid tissue damage. Such functions of the proposed device are evaluated through a series of experiments and the device is demonstrated to be effective.\n","PeriodicalId":55448,"journal":{"name":"Assembly Automation","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2022-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Assembly Automation","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.1108/aa-10-2021-0126","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
引用次数: 3

Abstract

Purpose The purpose of this paper is to design a smart handheld device with force regulating function, which demonstrates the concept of patient-specialized tools. Design/methodology/approach This handheld device integrates an electrical bioimpedance (EBI) sensor for tissue measurement and a constant force regulation mechanism for ensuring stable tool–tissue contact. Particular focuses in this study are on the design of the constant force regulation mechanism whose design process is through genetic algorithm optimization and finite element simulation. In addition, the output force can be changed to the desired value by adjusting the cross-sectional area of the generated spring. Findings The following two specific applications based on ex vivo tissues are used for evaluating the designed device. One is in terms of safety of interaction with delicate tissue while the other is for compensating involuntary tissue motion. The results of both examples show that the handheld device is able to provide an output force with a small standard deviation. Originality/value In this paper, a handheld device with force regulation mechanism is designed for specific patients based on the genetic algorithm optimization and finite element simulation. The device can maintain a steady and safe interaction force during the EBI measurement on fragile tissues or moving tissues, to improve the sensing accuracy and to avoid tissue damage. Such functions of the proposed device are evaluated through a series of experiments and the device is demonstrated to be effective.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
具有患者专用力调节机制的智能手持医疗设备
本文的目的是设计一种具有力调节功能的智能手持设备,展示患者专用工具的概念。该手持设备集成了用于组织测量的电生物阻抗(EBI)传感器和恒定力调节机制,以确保工具与组织的稳定接触。本研究的重点是恒力调节机构的设计,其设计过程是通过遗传算法优化和有限元模拟。另外,通过调节所生成弹簧的截面积,可将输出力改变为所需值。以下两个基于离体组织的具体应用用于评估设计的设备。一个是与脆弱组织相互作用的安全性,另一个是补偿不自主的组织运动。这两个例子的结果表明,手持装置能够提供一个小的标准偏差的输出力。本文基于遗传算法优化和有限元仿真,为特定患者设计了一种带力调节机构的手持设备。本装置在对脆弱组织或运动组织进行EBI测量时,能保持稳定、安全的相互作用力,提高传感精度,避免组织损伤。通过一系列实验对所提出的装置的这些功能进行了评估,并证明该装置是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Assembly Automation
Assembly Automation 工程技术-工程:制造
CiteScore
4.30
自引率
14.30%
发文量
51
审稿时长
3.3 months
期刊介绍: Assembly Automation publishes peer reviewed research articles, technology reviews and specially commissioned case studies. Each issue includes high quality content covering all aspects of assembly technology and automation, and reflecting the most interesting and strategically important research and development activities from around the world. Because of this, readers can stay at the very forefront of industry developments. All research articles undergo rigorous double-blind peer review, and the journal’s policy of not publishing work that has only been tested in simulation means that only the very best and most practical research articles are included. This ensures that the material that is published has real relevance and value for commercial manufacturing and research organizations.
期刊最新文献
The welding tracking technology of an underwater welding robot based on sliding mode active disturbance rejection control The application of robotics and artificial intelligence in embroidery: challenges and benefits Online modeling of environmental constraint region for complex-shaped parts assembly Adaptive neural prescribed performance control for switched pure-feedback non-linear systems with input quantization Automatic tolerance analyses by generation of assembly graph and mating edges from STEP AP 242 file of mechanical assembly
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1