{"title":"A Simple Device to Determine Ante-Version During Femoral Prosthesis Insertion in Total Hip Replacement","authors":"Ninad Godghate, N. Godghate, T. Drew, K. Saindane","doi":"10.52916/jmrs224093","DOIUrl":null,"url":null,"abstract":"Introduction: Good outcomes in Total Hip Replacement (THR) depend upon correct component alignment. This is influenced by the surgeon’s capacity to recreate a geometrically normal and biomechanically stable hip joint. Mal-positioining of components can lead to various complications and the surgeons have to make vital decisions intra-operatively based on their experience. Materials and Methods: This study describes a simple instrument to aid alignment of femoral stem insertion and hence achieve the normal range of ante-version between 10 º-20 º. Experiments performed on a saw bone model by twenty orthopaedic surgeons, each making six attempts to insert a prosthesis demonstrated improved positioning when compared to unaided insertion. Results: The mean average femoral stem ante-version unaided was 18.3 º (range, 4.9 º to 36.6 º). Device aided ante-version was 14.4 º (range, 9.8 º to 18.9 º) (p<0.001). We also report the practicality of the use of the device which was assessed by use on cadavers. Conclusion: Precise assessment of stem ante-version can be achieved in non-navigated THR if such a device is available intra-operatively.","PeriodicalId":73820,"journal":{"name":"Journal of medical research and surgery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of medical research and surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52916/jmrs224093","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Good outcomes in Total Hip Replacement (THR) depend upon correct component alignment. This is influenced by the surgeon’s capacity to recreate a geometrically normal and biomechanically stable hip joint. Mal-positioining of components can lead to various complications and the surgeons have to make vital decisions intra-operatively based on their experience. Materials and Methods: This study describes a simple instrument to aid alignment of femoral stem insertion and hence achieve the normal range of ante-version between 10 º-20 º. Experiments performed on a saw bone model by twenty orthopaedic surgeons, each making six attempts to insert a prosthesis demonstrated improved positioning when compared to unaided insertion. Results: The mean average femoral stem ante-version unaided was 18.3 º (range, 4.9 º to 36.6 º). Device aided ante-version was 14.4 º (range, 9.8 º to 18.9 º) (p<0.001). We also report the practicality of the use of the device which was assessed by use on cadavers. Conclusion: Precise assessment of stem ante-version can be achieved in non-navigated THR if such a device is available intra-operatively.