Effect of Preflaring on Accuracy of Endodontic Length Determination by Four Electronic Apex Locators

IF 0.2 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Dentistry Indonesia Pub Date : 2022-12-31 DOI:10.14693/jdi.v29i3.1337
A. Izadi, Maliheh Bayandari, Ezatolah Kazeminejad
{"title":"Effect of Preflaring on Accuracy of Endodontic Length Determination by Four Electronic Apex Locators","authors":"A. Izadi, Maliheh Bayandari, Ezatolah Kazeminejad","doi":"10.14693/jdi.v29i3.1337","DOIUrl":null,"url":null,"abstract":"Objective: Root canal anatomy significantly impacts the working length determination. This study aimed to investigate the effect of the preflaring technique on the accuracy of four electronic apex locators. Methods: Forty-five single-canal central maxillary teeth were selected. The working length was measured before and after the coronal preparation by four types of electronic apex locators in the range of ±0.5 and ±1 mm matched for the apical constriction. The actual working length was calculated under a microscope. Data were analyzed using ICC and paired t-tests in SPSS16. A p < 0.05 was considered significant. Results: The accuracies of Root ZX, DTE, Denjoy, and Coxo apex locators in the range of ± 0.05 mm were 71.1, 93.3, 84.4, and 75.6% before preflaring, and 82.2, 93.3, 97.8, and 100% after that. The corresponding values in the range of ±1 mm were 86.7, 97.8, 93.3, and 100% before and 97.8, 100, 100, and 100% after preflaring. Significant differences were found between the working lengths measured by the four devices and the actual working lengths before and after preflaring. Conclusion: The preflaring technique could impact the performance of apex locators in determining the working length and may be advocated for better outcomes.","PeriodicalId":53873,"journal":{"name":"Journal of Dentistry Indonesia","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2022-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dentistry Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14693/jdi.v29i3.1337","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

Objective: Root canal anatomy significantly impacts the working length determination. This study aimed to investigate the effect of the preflaring technique on the accuracy of four electronic apex locators. Methods: Forty-five single-canal central maxillary teeth were selected. The working length was measured before and after the coronal preparation by four types of electronic apex locators in the range of ±0.5 and ±1 mm matched for the apical constriction. The actual working length was calculated under a microscope. Data were analyzed using ICC and paired t-tests in SPSS16. A p < 0.05 was considered significant. Results: The accuracies of Root ZX, DTE, Denjoy, and Coxo apex locators in the range of ± 0.05 mm were 71.1, 93.3, 84.4, and 75.6% before preflaring, and 82.2, 93.3, 97.8, and 100% after that. The corresponding values in the range of ±1 mm were 86.7, 97.8, 93.3, and 100% before and 97.8, 100, 100, and 100% after preflaring. Significant differences were found between the working lengths measured by the four devices and the actual working lengths before and after preflaring. Conclusion: The preflaring technique could impact the performance of apex locators in determining the working length and may be advocated for better outcomes.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
四种电子根尖定位仪测定根管长度精度的影响
目的:根管解剖结构对工作长度的确定有显著影响。本研究旨在研究预极化技术对四个电子顶点定位器精度的影响。方法:选择上颌中央单管牙45颗。在冠状预备前后,通过四种类型的电子根尖定位器测量工作长度,其范围为±0.5和±1mm,与根尖收缩相匹配。实际工作长度是在显微镜下计算的。数据采用SPSS16中的ICC和配对t检验进行分析。p<0.05被认为是显著的。结果:Root ZX、DTE、Denjoy和Coxo顶点定位器在±0.05mm范围内的准确率在预极化前分别为71.1、93.3、84.4和75.6%,在预极化后分别为82.2、93.3和97.8和100%。±1mm范围内的相应值在预极化前分别为86.7、97.8、93.3和100%,在预极化后分别为97.8、100、100和100%。四个装置测量的工作长度与预极化前后的实际工作长度之间存在显著差异。结论:预极化技术可能会影响顶点定位器在确定工作长度方面的性能,并可能被提倡获得更好的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Dentistry Indonesia
Journal of Dentistry Indonesia DENTISTRY, ORAL SURGERY & MEDICINE-
自引率
0.00%
发文量
11
期刊最新文献
Factors Aff ors Affecting the Pr ecting the Preference of Or ence of Orthodontic Appliances thodontic Appliances Among Undergraduate Students in West Jakarta Evaluation of T aluation of Trabecular Bone Ar abecular Bone Around the Impacted Maxillar ound the Impacted Maxillary Canine on CBCT Images by Fractal Analysis Integration of Massive Open Online Course (MOOC) in Conventional Teaching and Learning for Fixed Prosthodontics - A Case Study Case Repor Case Report and X t and X-ray Microtomography and Scanning Electr aphy and Scanning Electron Microscopy Analysis of Teeth with Hypocalcified Amelogenesis Imperfecta Comparison of EDTA and Boric Acid Irrigation in Terms of Root Canal Dentin Microhardness and Sealer Penetration Depth
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1