Method for assessing the impact of residual roughness after corneal ablation simulated as random and filtered noise in polychromatic vision

IF 1.9 4区 物理与天体物理 Q3 OPTICS Journal of the European Optical Society-Rapid Publications Pub Date : 2023-03-21 DOI:10.1051/jeos/2023013
Shwetabh Verma
{"title":"Method for assessing the impact of residual roughness after corneal ablation simulated as random and filtered noise in polychromatic vision","authors":"Shwetabh Verma","doi":"10.1051/jeos/2023013","DOIUrl":null,"url":null,"abstract":"Purpose: Despite theoretical models for achieving laser-based ablation smoothness, methods do not yet exist for assessing the impact of residual roughness after corneal ablation, on retinal polychromatic vision. We developed a method and performed an exploratory study to qualitatively and quantitatively analyze the impact of varying degree of corneal roughness simulated through white and filtered noise, on the retinal image.\n\nMethods: A preliminary version of the Indiana Retinal Image Simulator (IRIS) (J Opt SocAm A Opt Image SciVis. 2008 Oct;25(10):2395-407) was used to simulate the polychromatic retinal image. Using patient-specific Zernike coefficients and pupil diameter, the impact of different levels of chromatic aberrations was calculated. Corneal roughness was modeled via both random and filtered noise (Biomed. Opt. Express 4, 220-229 (2013)), using distinct pre-calculated higher order Zernike coefficient terms. The outcome measures for the simulation were simulated retinal image, Strehl Ratio and Visual Strehl Ratio computed in frequency domain (VSOTF). The impact of varying degree of roughness (with and without refractive error), spatial frequency of the roughness, and pupil dilation was analyzed on these outcome measures. Standard simulation settings were pupil size = 6mm, Defocus Z[2,0] = 2 μm (-1.54D), and Spherical Aberrations Z[4,0] = 0.15 μm. The signal included the 2-4th Zernike orders, while noise used 7-8th Zernike orders. Noise was scaled to predetermined RMS values. All the terms in 5th and 6th Zernike order were set to 0, to avoid overlapping of signal and noise. \n\nResults: In case of a constant roughness term, reducing the pupil size resulted in improved outcome measures and simulated retinal image (Strehl = 0.005 for pupil size = 6mm to Strehl = 0.06 for pupil size = 3mm). The calculated image quality metrics deteriorated dramatically with increasing roughness (Strehl = 0. 3 for no noise; Strehl = 0.03 for random noise of 0.25µm at 6mm diameter; Strehl = 0.005 for random noise of 0.65µm at 6mm diameter). Clear distinction was observed in outcome measures for corneal roughness simulated as random noise compared to filtered noise, further influenced by the spatial frequency of filtered noise.\n\nConclusion: The proposed method enables quantifying the impact of residual roughness in corneal ablation processes at relatively low cost. Since normally laser ablation is an integral process divided on a defined grid, the impact of spatially characterized noise represents a more realistic simulation condition. This method can help comparing different refractive laser platforms in terms of their associated roughness in ablation, indirectly improving the quality of results after Laser vision correction surgery.\n","PeriodicalId":674,"journal":{"name":"Journal of the European Optical Society-Rapid Publications","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2023-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the European Optical Society-Rapid Publications","FirstCategoryId":"4","ListUrlMain":"https://doi.org/10.1051/jeos/2023013","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: Despite theoretical models for achieving laser-based ablation smoothness, methods do not yet exist for assessing the impact of residual roughness after corneal ablation, on retinal polychromatic vision. We developed a method and performed an exploratory study to qualitatively and quantitatively analyze the impact of varying degree of corneal roughness simulated through white and filtered noise, on the retinal image. Methods: A preliminary version of the Indiana Retinal Image Simulator (IRIS) (J Opt SocAm A Opt Image SciVis. 2008 Oct;25(10):2395-407) was used to simulate the polychromatic retinal image. Using patient-specific Zernike coefficients and pupil diameter, the impact of different levels of chromatic aberrations was calculated. Corneal roughness was modeled via both random and filtered noise (Biomed. Opt. Express 4, 220-229 (2013)), using distinct pre-calculated higher order Zernike coefficient terms. The outcome measures for the simulation were simulated retinal image, Strehl Ratio and Visual Strehl Ratio computed in frequency domain (VSOTF). The impact of varying degree of roughness (with and without refractive error), spatial frequency of the roughness, and pupil dilation was analyzed on these outcome measures. Standard simulation settings were pupil size = 6mm, Defocus Z[2,0] = 2 μm (-1.54D), and Spherical Aberrations Z[4,0] = 0.15 μm. The signal included the 2-4th Zernike orders, while noise used 7-8th Zernike orders. Noise was scaled to predetermined RMS values. All the terms in 5th and 6th Zernike order were set to 0, to avoid overlapping of signal and noise. Results: In case of a constant roughness term, reducing the pupil size resulted in improved outcome measures and simulated retinal image (Strehl = 0.005 for pupil size = 6mm to Strehl = 0.06 for pupil size = 3mm). The calculated image quality metrics deteriorated dramatically with increasing roughness (Strehl = 0. 3 for no noise; Strehl = 0.03 for random noise of 0.25µm at 6mm diameter; Strehl = 0.005 for random noise of 0.65µm at 6mm diameter). Clear distinction was observed in outcome measures for corneal roughness simulated as random noise compared to filtered noise, further influenced by the spatial frequency of filtered noise. Conclusion: The proposed method enables quantifying the impact of residual roughness in corneal ablation processes at relatively low cost. Since normally laser ablation is an integral process divided on a defined grid, the impact of spatially characterized noise represents a more realistic simulation condition. This method can help comparing different refractive laser platforms in terms of their associated roughness in ablation, indirectly improving the quality of results after Laser vision correction surgery.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
多色视觉中模拟随机和滤波噪声的角膜消融后残余粗糙度影响评估方法
目的:尽管有实现基于激光的消融平滑度的理论模型,但目前还没有评估角膜消融后残余粗糙度对视网膜多色视觉影响的方法。我们开发了一种方法,并进行了一项探索性研究,以定性和定量分析通过白色和过滤噪声模拟的不同程度的角膜粗糙度对视网膜图像的影响。方法:使用印第安纳州视网膜图像模拟器(IRIS)的初步版本(J Opt SocAm A Opt Image SciVis.2008年10月;25(10):2395-407)来模拟多色视网膜图像。使用患者特有的泽尼克系数和瞳孔直径,计算不同水平色差的影响。角膜粗糙度通过随机噪声和滤波噪声(Biomed.Opt.Express 4220-209(2013))建模,使用不同的预先计算的高阶泽尼克系数项。模拟的结果测量是模拟视网膜图像、频域计算的Strehl比率和视觉Strehl比率(VSOTF)。分析了不同粗糙度(有无折射误差)、粗糙度的空间频率和瞳孔扩张对这些结果测量的影响。标准模拟设置为瞳孔大小=6mm,散焦Z[2,0]=2μm(-1.54D),球面像差Z[4,0]=0.15μm。信号包括第2-4个Zernike阶,而噪声使用第7-8个Zernnike阶。噪声被缩放为预定的RMS值。Zernike第5和第6阶的所有项都设置为0,以避免信号和噪声的重叠。结果:在恒定粗糙度项的情况下,减小瞳孔大小可以改善结果测量和模拟视网膜图像(瞳孔大小=6mm时,Strehl=0.005;瞳孔大小=3mm时,Strehl=0.06)。计算的图像质量度量随着粗糙度的增加而急剧恶化(Strehl=0。3表示无噪声;Strehl=0.03,对于直径为6mm的0.25µm随机噪声;Strehl=0.005,对于直径6mm处0.65µm的随机噪声)。与滤波噪声相比,模拟为随机噪声的角膜粗糙度的结果测量有明显差异,滤波噪声的空间频率进一步影响了结果测量。结论:所提出的方法能够以相对较低的成本量化角膜消融过程中残余粗糙度的影响。由于激光烧蚀通常是在定义的网格上划分的积分过程,因此空间特征噪声的影响代表了更真实的模拟条件。该方法有助于比较不同屈光激光平台在消融过程中的相关粗糙度,间接提高激光视力矫正手术后的结果质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.40
自引率
0.00%
发文量
12
审稿时长
5 weeks
期刊介绍: Rapid progress in optics and photonics has broadened its application enormously into many branches, including information and communication technology, security, sensing, bio- and medical sciences, healthcare and chemistry. Recent achievements in other sciences have allowed continual discovery of new natural mysteries and formulation of challenging goals for optics that require further development of modern concepts and running fundamental research. The Journal of the European Optical Society – Rapid Publications (JEOS:RP) aims to tackle all of the aforementioned points in the form of prompt, scientific, high-quality communications that report on the latest findings. It presents emerging technologies and outlining strategic goals in optics and photonics. The journal covers both fundamental and applied topics, including but not limited to: Classical and quantum optics Light/matter interaction Optical communication Micro- and nanooptics Nonlinear optical phenomena Optical materials Optical metrology Optical spectroscopy Colour research Nano and metamaterials Modern photonics technology Optical engineering, design and instrumentation Optical applications in bio-physics and medicine Interdisciplinary fields using photonics, such as in energy, climate change and cultural heritage The journal aims to provide readers with recent and important achievements in optics/photonics and, as its name suggests, it strives for the shortest possible publication time.
期刊最新文献
Estimating the Absorption and Waveguiding in Porous Slabs from Multi-modal Measurements Towards a portable setup for the on-site SERS detection of miRNAs Orbital Angular Momentum Multiplexing Architecture for OAM/SDM Passive Optical Networks Analysis of the recording of Fibonacci lenses on photopolymers with 3-D diffusion model A method of fluorescence molecular tomographic reconstruction via the second-order sensitivity matrix
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1