Dong Hyeok Park, Mei Tong He, Eun Ju Cho, Karl Morten, Jeung Sang Go
{"title":"Development of a novel microfluidic perfusion 3D cell culture system for improved neuronal cell differentiation","authors":"Dong Hyeok Park, Mei Tong He, Eun Ju Cho, Karl Morten, Jeung Sang Go","doi":"10.1007/s10544-023-00660-4","DOIUrl":null,"url":null,"abstract":"<div><p>Three-dimensional (3D) cell cultures have recently gained popularity in the biomedical sciences because of their similarity to the <i>in vivo</i> environment. SH-SY5Y cells, which are neuronal cells and are commonly used to investigate neurodegenerative diseases, have particularly been reported to be differentiated as neuron-like cells expressing neuron-specific markers of mature neurons in static 3D culture environments when compared to static 2D environments, and those in perfusion environments have not yet been investigated. Microfluidic technology has provided perfusion environment which has more similarity to <i>in vivo</i> through mimicking vascular transportation of nutrients, but air bubbles entering into microchannels drastically increase instability of the flow. Furthermore, static incubation commonly used is incompatible with perfusion setup due to its air conditions, which is a critical huddle to the biologists. In the present study, we developed a novel microfluidic perfusion 3D cell culture system that overcomes the disturbance from air bubbles and intuitionally sets the incubation with the perfusion 3D culture. The system is capable of generating concentration gradients between 5 and 95% and air bubble traps were included to increase stability during incubation by collecting air bubbles. To evaluate the perfusion 3D culture, SH-SY5Y differentiation was examined in static 2D, static 3D, and perfusion 3D cultures. Our system supported significantly increased clustering of SH-SY5Y compared to static 2D and 3D methods, as well as increasing neurite growth rate. This novel system therefore supports differentiation of SH-SY5Y and can be used to more accurately model the <i>in vivo</i> environment during cell culture experiments.</p></div>","PeriodicalId":490,"journal":{"name":"Biomedical Microdevices","volume":"25 3","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2023-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10544-023-00660-4.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Microdevices","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10544-023-00660-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Three-dimensional (3D) cell cultures have recently gained popularity in the biomedical sciences because of their similarity to the in vivo environment. SH-SY5Y cells, which are neuronal cells and are commonly used to investigate neurodegenerative diseases, have particularly been reported to be differentiated as neuron-like cells expressing neuron-specific markers of mature neurons in static 3D culture environments when compared to static 2D environments, and those in perfusion environments have not yet been investigated. Microfluidic technology has provided perfusion environment which has more similarity to in vivo through mimicking vascular transportation of nutrients, but air bubbles entering into microchannels drastically increase instability of the flow. Furthermore, static incubation commonly used is incompatible with perfusion setup due to its air conditions, which is a critical huddle to the biologists. In the present study, we developed a novel microfluidic perfusion 3D cell culture system that overcomes the disturbance from air bubbles and intuitionally sets the incubation with the perfusion 3D culture. The system is capable of generating concentration gradients between 5 and 95% and air bubble traps were included to increase stability during incubation by collecting air bubbles. To evaluate the perfusion 3D culture, SH-SY5Y differentiation was examined in static 2D, static 3D, and perfusion 3D cultures. Our system supported significantly increased clustering of SH-SY5Y compared to static 2D and 3D methods, as well as increasing neurite growth rate. This novel system therefore supports differentiation of SH-SY5Y and can be used to more accurately model the in vivo environment during cell culture experiments.
期刊介绍:
Biomedical Microdevices: BioMEMS and Biomedical Nanotechnology is an interdisciplinary periodical devoted to all aspects of research in the medical diagnostic and therapeutic applications of Micro-Electro-Mechanical Systems (BioMEMS) and nanotechnology for medicine and biology.
General subjects of interest include the design, characterization, testing, modeling and clinical validation of microfabricated systems, and their integration on-chip and in larger functional units. The specific interests of the Journal include systems for neural stimulation and recording, bioseparation technologies such as nanofilters and electrophoretic equipment, miniaturized analytic and DNA identification systems, biosensors, and micro/nanotechnologies for cell and tissue research, tissue engineering, cell transplantation, and the controlled release of drugs and biological molecules.
Contributions reporting on fundamental and applied investigations of the material science, biochemistry, and physics of biomedical microdevices and nanotechnology are encouraged. A non-exhaustive list of fields of interest includes: nanoparticle synthesis, characterization, and validation of therapeutic or imaging efficacy in animal models; biocompatibility; biochemical modification of microfabricated devices, with reference to non-specific protein adsorption, and the active immobilization and patterning of proteins on micro/nanofabricated surfaces; the dynamics of fluids in micro-and-nano-fabricated channels; the electromechanical and structural response of micro/nanofabricated systems; the interactions of microdevices with cells and tissues, including biocompatibility and biodegradation studies; variations in the characteristics of the systems as a function of the micro/nanofabrication parameters.