Study on Transformer JED Cap Actuation Systems in the Field of Very Strong Electromagnetic Disturbances

A. Faryński, Tomasz Brodniewicz, J. Dębiński, Łukasz Słonkiewicz, Radosław Szymański, Zbigniew Ziółkowski
{"title":"Study on Transformer JED Cap Actuation Systems in the Field of Very Strong Electromagnetic Disturbances","authors":"A. Faryński, Tomasz Brodniewicz, J. Dębiński, Łukasz Słonkiewicz, Radosław Szymański, Zbigniew Ziółkowski","doi":"10.5604/01.3001.0014.5643","DOIUrl":null,"url":null,"abstract":"This work presents the results of research on the influence of strong external electromagnetic fields on the operation of JED spark caps activated by transformer systems. The tests were carried out in order to determine the conditions of safe use of JED caps installed in control systems of generators producing electric current pulses using the principle of an explosive magnetic field cumulation [1]. For this purpose, the measurements of the voltages induced in the transformer JED spark cap actuation system were performed using sinusoidal external current with an amplitude of 10 kA for a period of 15 microseconds. This current flowed at a distance from d = 10 mm to d = 40 mm from the axis of the ferrite cores of the applied transformers: a closed core with an outer diameter of 20 mm, an inner diameter of 10 mm and a height of 10 mm and an open core with \na diameter of 6 mm and a length of 25 mm. The transformers used in Air Force Institute of Technology (AFIT) were placed alternately parallel and perpendicular to the axis of the current conductor. In the case of a transformer with a cylindrical open core perpendicular to the current axis, the induced voltages significantly exceeded the values at which the caps were activated (about 2 kV) and became lower than these values at \nd of about 40 mm. Toroidal closed cores provided induced voltages of up to 200 V (10 times lower) for all configurations tested. The measurements were performed using a system and methods developed at AFIT.\n\n","PeriodicalId":52820,"journal":{"name":"Problemy Mechatroniki","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Problemy Mechatroniki","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0014.5643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work presents the results of research on the influence of strong external electromagnetic fields on the operation of JED spark caps activated by transformer systems. The tests were carried out in order to determine the conditions of safe use of JED caps installed in control systems of generators producing electric current pulses using the principle of an explosive magnetic field cumulation [1]. For this purpose, the measurements of the voltages induced in the transformer JED spark cap actuation system were performed using sinusoidal external current with an amplitude of 10 kA for a period of 15 microseconds. This current flowed at a distance from d = 10 mm to d = 40 mm from the axis of the ferrite cores of the applied transformers: a closed core with an outer diameter of 20 mm, an inner diameter of 10 mm and a height of 10 mm and an open core with a diameter of 6 mm and a length of 25 mm. The transformers used in Air Force Institute of Technology (AFIT) were placed alternately parallel and perpendicular to the axis of the current conductor. In the case of a transformer with a cylindrical open core perpendicular to the current axis, the induced voltages significantly exceeded the values at which the caps were activated (about 2 kV) and became lower than these values at d of about 40 mm. Toroidal closed cores provided induced voltages of up to 200 V (10 times lower) for all configurations tested. The measurements were performed using a system and methods developed at AFIT.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
变压器极强电磁干扰下JED帽驱动系统的研究
本文介绍了强外部电磁场对变压器系统激活的JED火花帽运行影响的研究结果。试验是为了确定安装在利用爆炸磁场累积原理产生电流脉冲的发电机控制系统中的JED帽的安全使用条件。为此,测量变压器JED火花帽驱动系统中产生的电压,使用振幅为10 kA的正弦外部电流,持续15微秒。该电流从应用变压器铁氧体铁芯轴线d = 10mm到d = 40mm的距离流过:外径为20mm的封闭铁芯,内径为10mm,高为10mm,开式铁芯,直径为6mm,长为25mm。空军理工学院(AFIT)使用的变压器与电流导体的轴线平行或垂直交替放置。在垂直于电流轴的圆柱形开铁芯变压器的情况下,感应电压明显超过了帽被激活时的值(约2kv),并在d约40mm时低于这些值。环形封闭铁芯提供感应电压高达200v(低10倍)的所有配置测试。使用AFIT开发的系统和方法进行测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
23
审稿时长
53 weeks
期刊最新文献
Testing the Mechanical Response of Additively Manufactured Composite Joints Development of a Method of Analysing TNT and its Derivatives in the Trichoptera Larvae of the Genus Hydropsyche Angustipennis, Curtis 1834, Selected as a Bioaccumulation Indicator for the Detection of Aquatic Environment Pollution with Explosive Residues The Complete Set of Distinguishable Diagnostic States for a Centrifugal Pump System Development of a Solid, Low-Smoke Rocket Propellant – Smoke Generation Intensity Tests Using a Laser and Photodiode Setup Badania lotu przeciwpancernego pocisku kierowanego Pirat z funkcją „top attack”
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1