Verification of dose distribution by different material properties in intraoral mold irradiation

IF 0.3 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Radiotherapy in Practice Pub Date : 2023-07-20 DOI:10.1017/S1460396923000286
H. Fuse, Fumihiro Tomita, Kenji Yasue, Hideaki Ikoma, Shin Miyakawa, Norikazu Kori, T. Fujisaki, Y. Ishimori, M. Monma, T. Okumura, Y. Tamaki
{"title":"Verification of dose distribution by different material properties in intraoral mold irradiation","authors":"H. Fuse, Fumihiro Tomita, Kenji Yasue, Hideaki Ikoma, Shin Miyakawa, Norikazu Kori, T. Fujisaki, Y. Ishimori, M. Monma, T. Okumura, Y. Tamaki","doi":"10.1017/S1460396923000286","DOIUrl":null,"url":null,"abstract":"Abstract Background: Brachytherapy is an effective local treatment for early-stage head and neck cancers. Mold irradiation is a method in which the source is placed in the oral cavity in sites where the soft tissue is thin and an irradiation source cannot be implanted. However, dose calculations based on TG-43 may be subject to uncertainty due to the heterogeneity of tissues and materials used for the irradiation of head and neck cancers. Materials and Methods: In this study, we investigated the basic physical properties of different materials and densities in the molds, retrospectively analysed patient plans and verified the doses of intraoral mold irradiation using a dose verification system with MC simulations specifically designed for brachytherapy, which was constructed independently. Results and Discussion: Dose–volume histograms were obtained with a treatment planning system (TG-43) and MC simulation and revealed a non-negligible difference in coverage of high-risk clinical target volume (HR-CTV) and organ at risk (OAR) between calculations using computed tomography values and those with density changes. The underdose was 10·6%, 3·7% and 5·6% for HR-CTV, gross tumour volume and OAR, respectively, relative to the treatment plan. The calculations based on the differences in the elemental composition and density changes in TG-43, a water-based calculation algorithm, resulted in clinically significant dose differences. The validation method was used only for the cases of complex small source therapy. Conclusion: The findings of this study can be applied to more complex cases with steeper density gradients, such as mold irradiation.","PeriodicalId":44597,"journal":{"name":"Journal of Radiotherapy in Practice","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiotherapy in Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/S1460396923000286","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background: Brachytherapy is an effective local treatment for early-stage head and neck cancers. Mold irradiation is a method in which the source is placed in the oral cavity in sites where the soft tissue is thin and an irradiation source cannot be implanted. However, dose calculations based on TG-43 may be subject to uncertainty due to the heterogeneity of tissues and materials used for the irradiation of head and neck cancers. Materials and Methods: In this study, we investigated the basic physical properties of different materials and densities in the molds, retrospectively analysed patient plans and verified the doses of intraoral mold irradiation using a dose verification system with MC simulations specifically designed for brachytherapy, which was constructed independently. Results and Discussion: Dose–volume histograms were obtained with a treatment planning system (TG-43) and MC simulation and revealed a non-negligible difference in coverage of high-risk clinical target volume (HR-CTV) and organ at risk (OAR) between calculations using computed tomography values and those with density changes. The underdose was 10·6%, 3·7% and 5·6% for HR-CTV, gross tumour volume and OAR, respectively, relative to the treatment plan. The calculations based on the differences in the elemental composition and density changes in TG-43, a water-based calculation algorithm, resulted in clinically significant dose differences. The validation method was used only for the cases of complex small source therapy. Conclusion: The findings of this study can be applied to more complex cases with steeper density gradients, such as mold irradiation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
口腔内霉菌照射中不同材料特性剂量分布的验证
摘要背景:近距离治疗是早期头颈癌的一种有效的局部治疗方法。霉菌照射是一种将放射源放置在口腔中软组织较薄且无法植入放射源的部位的方法。然而,由于用于头颈癌照射的组织和材料的异质性,基于TG-43的剂量计算可能存在不确定性。材料和方法:在这项研究中,我们研究了模具中不同材料和密度的基本物理特性,回顾性分析了患者计划,并使用专门为近距离放射治疗设计的MC模拟剂量验证系统验证了口内模具照射的剂量,该系统是独立构建的。结果和讨论:使用治疗计划系统(TG-43)和MC模拟获得剂量-体积直方图,并显示使用计算机断层扫描值和密度变化的计算之间,高风险临床目标体积(HR-CTV)和危险器官(OAR)的覆盖率存在不可忽略的差异。相对于治疗计划,HR-CTV、肿瘤总体积和OAR的欠剂量分别为10.6%、3.7%和5.6%。基于TG-43(一种基于水的计算算法)中元素组成和密度变化的差异进行的计算导致了临床上显著的剂量差异。该验证方法仅用于复杂小来源治疗的病例。结论:本研究结果可应用于密度梯度更陡的更复杂病例,如霉菌照射。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Radiotherapy in Practice
Journal of Radiotherapy in Practice RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
0.80
自引率
0.00%
发文量
36
期刊介绍: Journal of Radiotherapy in Practice is a peer-reviewed journal covering all of the current modalities specific to clinical oncology and radiotherapy. The journal aims to publish research from a wide range of styles and encourage debate and the exchange of information and opinion from within the field of radiotherapy practice and clinical oncology. The journal also aims to encourage technical evaluations and case studies as well as equipment reviews that will be of interest to an international radiotherapy audience.
期刊最新文献
Wobbling nature of gamma passing rate as a function of calibration field sizes in patient-specific quality assurance Secondary fragmentation and relative biological effectiveness (RBE) study using Bridge SOI microdosimeter: Monte Carlo simulation Keratin-based topical cream for radiation dermatitis during head and neck radiotherapy: a randomised, open-label pilot study. Single catheter 3d volume based hybrid inverse planning optimization in IVBT can improve organ sparing – CORRIGENDUM Dosimetric case study of 3-D FiF vs. VMAT techniques in the treatment of H/N tumour
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1