Influence of Protease Inhibitors on Bond Degradation of Self-Etch Adhesive Systems to Caries-Affected Dentin: An in Vitro Study

Diana Roberta Pereira Grandizoli, S. Pinheiro
{"title":"Influence of Protease Inhibitors on Bond Degradation of Self-Etch Adhesive Systems to Caries-Affected Dentin: An in Vitro Study","authors":"Diana Roberta Pereira Grandizoli, S. Pinheiro","doi":"10.4236/ABC.2018.81002","DOIUrl":null,"url":null,"abstract":"Background: A decline in pH and dissolution of the inorganic content of the dental tissues are followed by exposure of the organic portion of the tooth, which, in dentin, is largely composed of collagen fibres. These unprotected fibres are then degraded by metalloproteinases and cysteine cathepsins, proteolytic enzymes present in dentin. We evaluated the influence of protease inhibitors on the bond strength of a self-etch adhesive system to caries-affected dentin. Eighty permanent third molars were selected for the study. Dentinal caries were induced artificially by the microbial method and the teeth were divided in four groups: G1—application of Clearfil SE Bond adhesive system (CL); G2—2% chlorhexidine (CLX) + CL; G3—sodium bicarbonate (BIC) + CL; G4—BI + CLX + CL. Bond strength was assessed immediately and at six months. During the six months, the specimens were stored in distilled water. Microtensile bond strength testing was performed. On immediate testing, there was no significant difference in bond strength across the control, BIC, and CLX groups. The combination of BIC + CLX, however, led to an immediate, significant reduction in bond strength. After six months, bond strength was reduced in all groups. The highest bond strength was obtained in the control group (P < 0.05). Most fractures were adhesive, both immediately and at six months. We concluded that the cavity pretreatment with 2% CLX or 2% BIC did not have an immediate negative impact on bond strength of the Clearfil SE Bond system. After specimens were stored for six months in water, their bond strength of specimens was reduced in all groups. This reduction was the greatest in the groups exposed to the inhibitors.","PeriodicalId":59114,"journal":{"name":"生物化学进展(英文)","volume":"08 1","pages":"15-28"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"生物化学进展(英文)","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.4236/ABC.2018.81002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: A decline in pH and dissolution of the inorganic content of the dental tissues are followed by exposure of the organic portion of the tooth, which, in dentin, is largely composed of collagen fibres. These unprotected fibres are then degraded by metalloproteinases and cysteine cathepsins, proteolytic enzymes present in dentin. We evaluated the influence of protease inhibitors on the bond strength of a self-etch adhesive system to caries-affected dentin. Eighty permanent third molars were selected for the study. Dentinal caries were induced artificially by the microbial method and the teeth were divided in four groups: G1—application of Clearfil SE Bond adhesive system (CL); G2—2% chlorhexidine (CLX) + CL; G3—sodium bicarbonate (BIC) + CL; G4—BI + CLX + CL. Bond strength was assessed immediately and at six months. During the six months, the specimens were stored in distilled water. Microtensile bond strength testing was performed. On immediate testing, there was no significant difference in bond strength across the control, BIC, and CLX groups. The combination of BIC + CLX, however, led to an immediate, significant reduction in bond strength. After six months, bond strength was reduced in all groups. The highest bond strength was obtained in the control group (P < 0.05). Most fractures were adhesive, both immediately and at six months. We concluded that the cavity pretreatment with 2% CLX or 2% BIC did not have an immediate negative impact on bond strength of the Clearfil SE Bond system. After specimens were stored for six months in water, their bond strength of specimens was reduced in all groups. This reduction was the greatest in the groups exposed to the inhibitors.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
蛋白酶抑制剂对龋病牙本质自蚀刻粘接系统键降解的影响:体外研究
背景:pH值下降和牙组织的无机含量溶解后,牙齿的有机部分暴露出来,在牙本质中,有机部分主要由胶原纤维组成。这些未受保护的纤维随后被金属蛋白酶和半胱氨酸组织蛋白酶(存在于牙本质中的蛋白水解酶)降解。我们评估了蛋白酶抑制剂对自蚀刻粘接系统与受龋影响的牙本质的结合强度的影响。80颗恒第三磨牙被选为研究对象。采用微生物法人工诱导牙髓龋,分为4组:g1组(应用Clearfil SE Bond粘接剂系统);G2-2%氯己定(CLX) + CL;g3 -碳酸氢钠(BIC) + CL;G4-bi + CLX + cl。分别在6个月时和立即评估粘结强度。在六个月的时间里,标本被保存在蒸馏水中。进行了微拉伸粘结强度测试。在即时测试中,对照组、BIC组和CLX组之间的粘合强度没有显著差异。然而,BIC + CLX的组合会立即导致粘结强度的显著降低。6个月后,所有组的粘接强度都降低了。结合力以对照组最高(P < 0.05)。大多数骨折都是粘连的,无论是立即还是六个月大的时候。我们得出结论,2% CLX或2% BIC的空腔预处理不会对Clearfil SE bond系统的结合强度产生直接的负面影响。在水中保存6个月后,各组标本的粘结强度均有所降低。这种减少在暴露于抑制剂的组中是最大的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
251
期刊最新文献
Radiation-Induced Chromosome Instability in WTK1 and TK6 Human Lymphoblastoid Cells Association between Metabolic Syndrome Components and Serum High-Sensitivity C-Reactive Protein or Interleukin-6 Levels among Congolese Adults Possible Relevance of the Allende Meteorite Conditions in Prebiotic Chemistry: An Insight into the Chondrules and Organic Compounds Persistently High Glycated Hemoglobin in a Subgroup of Type 2 Diabetic Patients Who Failed Usual Oral Antihyperglycemics and Insulin in Côte d’Ivoire Starch Metabolism in Plant and Its Applications in Food Industry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1