An Automated Measurement of Image Slice Thickness of Computed Tomography

IF 0.6 Q4 NUCLEAR SCIENCE & TECHNOLOGY Atom Indonesia Pub Date : 2021-08-05 DOI:10.17146/aij.2021.1111
S. Sofiyatun, C. Anam, Ummu Mar'atu Zahro, D. A. Rukmana, G. Dougherty
{"title":"An Automated Measurement of Image Slice Thickness of Computed Tomography","authors":"S. Sofiyatun, C. Anam, Ummu Mar'atu Zahro, D. A. Rukmana, G. Dougherty","doi":"10.17146/aij.2021.1111","DOIUrl":null,"url":null,"abstract":"Measurement of the slice thickness in computed tomography (CT) is usually made using a special phantom, such as the AAPM CT performance phantom. Images of the phantom are analyzed manually and subjectively. The purpose of this study is to develop an automated system for measuring the slice thickness of the CT image of the phantom using MATLAB software. The CT AAPM performance phantom was scanned by a 128 multi-slice computed tomography scanner (Revolution Evo, GE Healthcare, Waukesha, WI) at a slice thickness of 5 mm with four different phantom orientations and also scanned by a 6 multi-slice CT scanner (Somatom Emotion 6, Siemens AG, Forchheim, Germany) for two slice thicknesses of 5 and 10 mm. Our automat ed method produce d an accurate slice thickness value less than 0.5 mm different from the nominal slice thicknesses and manual measurements. Similar results were obtained when the phantom was rotated. This system is more objective and effective compared to manual systems.","PeriodicalId":8647,"journal":{"name":"Atom Indonesia","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2021-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atom Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17146/aij.2021.1111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 9

Abstract

Measurement of the slice thickness in computed tomography (CT) is usually made using a special phantom, such as the AAPM CT performance phantom. Images of the phantom are analyzed manually and subjectively. The purpose of this study is to develop an automated system for measuring the slice thickness of the CT image of the phantom using MATLAB software. The CT AAPM performance phantom was scanned by a 128 multi-slice computed tomography scanner (Revolution Evo, GE Healthcare, Waukesha, WI) at a slice thickness of 5 mm with four different phantom orientations and also scanned by a 6 multi-slice CT scanner (Somatom Emotion 6, Siemens AG, Forchheim, Germany) for two slice thicknesses of 5 and 10 mm. Our automat ed method produce d an accurate slice thickness value less than 0.5 mm different from the nominal slice thicknesses and manual measurements. Similar results were obtained when the phantom was rotated. This system is more objective and effective compared to manual systems.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
计算机断层扫描图像切片厚度的自动测量
计算机断层扫描(CT)中切片厚度的测量通常使用特殊的体模,例如AAPM CT性能体模。人工和主观地分析体模的图像。本研究的目的是使用MATLAB软件开发一个用于测量体模CT图像切片厚度的自动化系统。CT AAPM性能体模由128多层计算机断层扫描仪(Revolution Evo,GE Healthcare,Waukesha,WI)以5mm的切片厚度以四种不同的体模方向扫描,还由6多层CT扫描仪(Somatom Emotion 6,Siemens AG,Forchheim,Germany)以5mm和10mm的两种切片厚度扫描。我们的自动化方法产生的准确切片厚度值与标称切片厚度和手动测量值相差不到0.5 mm。当旋转体模时获得了类似的结果。与手动系统相比,该系统更加客观有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Atom Indonesia
Atom Indonesia NUCLEAR SCIENCE & TECHNOLOGY-
CiteScore
1.00
自引率
0.00%
发文量
20
审稿时长
16 weeks
期刊介绍: The focus of Atom Indonesia is research and development in nuclear science and technology. The scope of this journal covers experimental and analytical research in nuclear science and technology. The topics include nuclear physics, reactor physics, radioactive waste, fuel element, radioisotopes, radiopharmacy, radiation, and neutron scattering, as well as their utilization in agriculture, industry, health, environment, energy, material science and technology, and related fields.
期刊最新文献
External Bremsstrahlung Studies on Films of Lead Monoxide Filled Polycarbonate Composite Radon Concentration in Urban Areas in the North and West of Morocco Geologic Influence on Radon Concentrations Levels in Cave: A Case Study of Mimpi Cave in the Maros Karst of South Sulawesi, Indonesia Elemental Mapping and Quantities in Different Soybean Seed Colors Using Micro X-Ray Fluorescence and Their Correlations with Germination Assessment of 137Cs in the Environment of Hetauda City, Nepal by In-Situ Gamma Ray Spectrometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1