Evaluation of the usefulness of the Monte Carlo method for estimating the optimization of hemodialysis

Q3 Medicine Physics in Medicine Pub Date : 2021-12-01 DOI:10.1016/j.phmed.2021.100035
Agnieszka Gala-Błądzińska , Krystyna Tęcza , Wojciech Żyłka , Piotr Prach , Maciej Błądziński , Paweł Jakubczyk
{"title":"Evaluation of the usefulness of the Monte Carlo method for estimating the optimization of hemodialysis","authors":"Agnieszka Gala-Błądzińska ,&nbsp;Krystyna Tęcza ,&nbsp;Wojciech Żyłka ,&nbsp;Piotr Prach ,&nbsp;Maciej Błądziński ,&nbsp;Paweł Jakubczyk","doi":"10.1016/j.phmed.2021.100035","DOIUrl":null,"url":null,"abstract":"<div><p>Adequate hemodialysis minimizes complications and improves end-stage renal disease patient survival. Our study proposed a methodology for estimating hemodialysis parameters using two-compartment modelling together with Monte Carlo simulation of the probabilities of the model outputs. In addition, we modelled the removal of uremic toxins during hemodialysis, in comparison with the actual concentration of these toxins in the blood serum. Blood urea and phosphates were measured every 30 min throughout hemodialysis in 10 patients. Using a Monte Carlo simulation on the two-compartment model we estimated hemodialysis compatibility parameters for each patient individually. In patients with non-diabetic kidney disease, the actual urea and phosphate excretion dynamics were consistent with those predicted by the two-compartment model regardless of age, sex, non-diabetic comorbidities, duration of hemodialysis, residual diuresis, or type of vascular access. To measure compatibility, we used graph matching together with a quantitative measure given by a normalized coefficient of determination. In patients with end-stage diabetic kidney disease, the toxin elimination dynamics were significantly greater in the first 30 min of hemodialysis than in patients with non-diabetic kidney disease.</p></div>","PeriodicalId":37787,"journal":{"name":"Physics in Medicine","volume":"12 ","pages":"Article 100035"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.phmed.2021.100035","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352451021000019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

Adequate hemodialysis minimizes complications and improves end-stage renal disease patient survival. Our study proposed a methodology for estimating hemodialysis parameters using two-compartment modelling together with Monte Carlo simulation of the probabilities of the model outputs. In addition, we modelled the removal of uremic toxins during hemodialysis, in comparison with the actual concentration of these toxins in the blood serum. Blood urea and phosphates were measured every 30 min throughout hemodialysis in 10 patients. Using a Monte Carlo simulation on the two-compartment model we estimated hemodialysis compatibility parameters for each patient individually. In patients with non-diabetic kidney disease, the actual urea and phosphate excretion dynamics were consistent with those predicted by the two-compartment model regardless of age, sex, non-diabetic comorbidities, duration of hemodialysis, residual diuresis, or type of vascular access. To measure compatibility, we used graph matching together with a quantitative measure given by a normalized coefficient of determination. In patients with end-stage diabetic kidney disease, the toxin elimination dynamics were significantly greater in the first 30 min of hemodialysis than in patients with non-diabetic kidney disease.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评价蒙特卡罗方法对血液透析优化的有效性
充分的血液透析可以减少并发症,提高终末期肾病患者的生存率。我们的研究提出了一种估算血液透析参数的方法,使用双室建模以及模型输出概率的蒙特卡罗模拟。此外,我们模拟了血液透析过程中尿毒症毒素的去除,并与血清中这些毒素的实际浓度进行了比较。10例患者在血液透析过程中每30 min测定一次尿素和磷酸盐。使用蒙特卡罗模拟双室模型,我们估计每个病人的血液透析相容性参数。在非糖尿病肾病患者中,无论年龄、性别、非糖尿病合并症、血液透析持续时间、残余利尿或血管通路类型如何,实际的尿素和磷酸盐排泄动态与双室模型预测的结果一致。为了测量兼容性,我们使用图匹配和由归一化决定系数给出的定量度量。在终末期糖尿病肾病患者中,血液透析的前30分钟毒素消除动力学明显大于非糖尿病肾病患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Physics in Medicine
Physics in Medicine Physics and Astronomy-Instrumentation
CiteScore
2.60
自引率
0.00%
发文量
9
审稿时长
12 weeks
期刊介绍: The scope of Physics in Medicine consists of the application of theoretical and practical physics to medicine, physiology and biology. Topics covered are: Physics of Imaging Ultrasonic imaging, Optical imaging, X-ray imaging, Fluorescence Physics of Electromagnetics Neural Engineering, Signal analysis in Medicine, Electromagnetics and the nerve system, Quantum Electronics Physics of Therapy Ultrasonic therapy, Vibrational medicine, Laser Physics Physics of Materials and Mechanics Physics of impact and injuries, Physics of proteins, Metamaterials, Nanoscience and Nanotechnology, Biomedical Materials, Physics of vascular and cerebrovascular diseases, Micromechanics and Micro engineering, Microfluidics in medicine, Mechanics of the human body, Rotary molecular motors, Biological physics, Physics of bio fabrication and regenerative medicine Physics of Instrumentation Engineering of instruments, Physical effects of the application of instruments, Measurement Science and Technology, Physics of micro-labs and bioanalytical sensor devices, Optical instrumentation, Ultrasound instruments Physics of Hearing and Seeing Acoustics and hearing, Physics of hearing aids, Optics and vision, Physics of vision aids Physics of Space Medicine Space physiology, Space medicine related Physics.
期刊最新文献
Simulation of the Positron Emission Mammography system based on the Monte Carlo method by considering the effects of Time Of Flight (TOF) and Depth Of Interaction (DOI) Shape-preserving average frequency response curves using rational polynomials: A case study on human stapes vibration measurements Nickel-based catalysts for non-enzymatic electrochemical sensing of glucose: A review Cost-effective, scalable and smartphone-controlled 3D-Printed syringe pump - From lab bench to point of care biosensing applications Rapid electrochemical detection of levodopa using polyaniline-modified screen-printed electrodes for the improved management of Parkinson's disease
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1