Investigation of Dehydroxylated Sodium Bentonite as a Pozzolanic Extender in Oil-Well Cement

IF 1.3 4区 工程技术 Q3 ENGINEERING, PETROLEUM SPE Drilling & Completion Pub Date : 2021-04-01 DOI:10.2118/205487-PA
Stephen Adjei, S. Elkatatny, P. Sarmah, Gonzalo Chinea
{"title":"Investigation of Dehydroxylated Sodium Bentonite as a Pozzolanic Extender in Oil-Well Cement","authors":"Stephen Adjei, S. Elkatatny, P. Sarmah, Gonzalo Chinea","doi":"10.2118/205487-PA","DOIUrl":null,"url":null,"abstract":"\n Fly ash, which is a pozzolan generated as a byproduct from coal-powered plants, is the most used extender in the design of lightweight cement. However, the coal-powered plants are phasing out due to global-warming concerns. There is the need to investigate other materials as substitutes to fly ash. Bentonite is a natural pozzolanic material that is abundant in nature. This pozzolanic property is enhanced upon heat treatment; however, this material has never been explored in oil-well cementing in such form. This study compares the performance of 13-ppg heated (dehydroxylated) sodium bentonite and fly-ash cement systems.\n The raw (commercial) sodium bentonite was dehydroxylated at 1,526°F for 3 hours. Cement slurries were prepared at 13 ppg using the heated sodium bentonite as partial replacements of cement in concentrations of 10 to 50% by weight of blend. Various tests were done at a bottomhole static temperature of 120°F, bottomhole circulating temperature of 110°F, and pressure of 1,000 psi or atmospheric pressure.\n All the dehydroxylated sodium bentonite systems exhibited high stability, thickening times in the range of 3 to 5 hours, and a minimum 24-hour compressive strength of 600 psi. At a concentration of 40 and 50%, the 24-hour compressive strength was approximately 800 and 787 psi, respectively. This was higher than a 13-ppg fly-ash-based cement designed at 40% cement replacement (580 psi).","PeriodicalId":51165,"journal":{"name":"SPE Drilling & Completion","volume":"1 1","pages":"1-8"},"PeriodicalIF":1.3000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SPE Drilling & Completion","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2118/205487-PA","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, PETROLEUM","Score":null,"Total":0}
引用次数: 2

Abstract

Fly ash, which is a pozzolan generated as a byproduct from coal-powered plants, is the most used extender in the design of lightweight cement. However, the coal-powered plants are phasing out due to global-warming concerns. There is the need to investigate other materials as substitutes to fly ash. Bentonite is a natural pozzolanic material that is abundant in nature. This pozzolanic property is enhanced upon heat treatment; however, this material has never been explored in oil-well cementing in such form. This study compares the performance of 13-ppg heated (dehydroxylated) sodium bentonite and fly-ash cement systems. The raw (commercial) sodium bentonite was dehydroxylated at 1,526°F for 3 hours. Cement slurries were prepared at 13 ppg using the heated sodium bentonite as partial replacements of cement in concentrations of 10 to 50% by weight of blend. Various tests were done at a bottomhole static temperature of 120°F, bottomhole circulating temperature of 110°F, and pressure of 1,000 psi or atmospheric pressure. All the dehydroxylated sodium bentonite systems exhibited high stability, thickening times in the range of 3 to 5 hours, and a minimum 24-hour compressive strength of 600 psi. At a concentration of 40 and 50%, the 24-hour compressive strength was approximately 800 and 787 psi, respectively. This was higher than a 13-ppg fly-ash-based cement designed at 40% cement replacement (580 psi).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
脱氢钠膨润土作为油井水泥中火山灰填充剂的研究
粉煤灰是燃煤电厂产生的副产品,是轻质水泥设计中使用最多的填充剂。然而,由于对全球变暖的担忧,燃煤电厂正在逐步淘汰。有必要研究其他材料作为粉煤灰的替代品。膨润土是自然界中储量丰富的天然火山灰材料。这种火山灰性质在热处理后得到增强;然而,这种材料从未以这种形式应用于油井固井。本研究比较了13ppg加热(去羟基化)钠膨润土和粉煤灰水泥体系的性能。原料(商品)钠膨润土在1526°F下脱氢3小时。在13 ppg的条件下,使用加热的钠基膨润土作为水泥的部分替代品,以10 - 50%的混合质量浓度制备水泥浆。在井底静态温度为120°F、井底循环温度为110°F、压力为1,000 psi或大气压的条件下进行了各种测试。所有脱羟化钠膨润土体系均表现出高稳定性,增稠时间在3至5小时之间,最小24小时抗压强度为600 psi。在浓度为40%和50%时,24小时抗压强度分别约为800和787 psi。这比在40%水泥替换量(580 psi)下设计的13 ppg粉煤灰基水泥要高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
SPE Drilling & Completion
SPE Drilling & Completion 工程技术-工程:石油
CiteScore
4.20
自引率
7.10%
发文量
29
审稿时长
6-12 weeks
期刊介绍: Covers horizontal and directional drilling, drilling fluids, bit technology, sand control, perforating, cementing, well control, completions and drilling operations.
期刊最新文献
Combining Magnetic and Gyroscopic Surveys Provides the Best Possible Accuracy Applications of Machine Learning Methods to Predict Hole Cleaning in Horizontal and Highly Deviated Wells Experimental Investigation of Geopolymers for Application in High-Temperature and Geothermal Well Cementing Analysis of Riser Gas Pressure from Full-Scale Gas-in-Riser Experiments with Instrumentation Correlating Surface and Downhole Perforation Entry Hole Measurements Leads to Development of Improved Perforating Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1