{"title":"Risk Factors for Complex Hypersensitivity and Irritation Reactions after an Ultrasound-Guided Cyanoacrylate Closure","authors":"Seung goo Lee, Sungsin Cho, J. Joh","doi":"10.46268/JSU.2021.8.1.19","DOIUrl":null,"url":null,"abstract":"Purpose: Cyanoacrylate closure (CAC) has been introduced for the treatment of the incompetent saphenous vein. Although there have been no severe procedure- or device-related adverse events, the post-treatment complex hypersensitivity and irritation reactions (CHAIR) might be a troublesome complication. Methods: A retrospective review was performed from prospectively collected data of CAC patients. The CAC was performed in patients with symptomatic great saphenous veins (GSV), small saphenous veins (SSV), and/or accessory saphenous veins (ASV) in a single session. We assessed the possible risk factors for the development of a hypersensitivity reaction including the amount of injected adhesive, access site, treated segment, compression stocking application, and other clinical factors. For the statistical analyses, data were analyzed using the IBM SPSS Statistics ver. 22.0 (IBM Co., Armonk, NY, USA). P-value <0.05 was considered statistically significant. Results: During the study period, 190 saphenous veins were treated in 100 patients. Sixty-four (64%) patients were female. The mean age was 55.5 ± 12.8 years (19-84). Complete occlusion was achieved in all patients. After CAC, the mean visual analogue scale (VAS) was 2.59 and 0.32 on postoperative 0 and 7 days, respectively (P < 0.001). Post-treat-ment CHAIR occurred in 5 (5%) patients. The significant risk factors for the development of CHAIR were younger age, GSV treatment, and below-the-knee access site for the introduction of a catheter. Conclusion: CHAIR occurred when the adhesive was injected at the below-the-knee GSV segment. The mechanical irritation due to knee joint movement might be a possible mechanism for the development of the hypersensitivity reaction.","PeriodicalId":33937,"journal":{"name":"Journal of Surgical Ultrasound","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Surgical Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46268/JSU.2021.8.1.19","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: Cyanoacrylate closure (CAC) has been introduced for the treatment of the incompetent saphenous vein. Although there have been no severe procedure- or device-related adverse events, the post-treatment complex hypersensitivity and irritation reactions (CHAIR) might be a troublesome complication. Methods: A retrospective review was performed from prospectively collected data of CAC patients. The CAC was performed in patients with symptomatic great saphenous veins (GSV), small saphenous veins (SSV), and/or accessory saphenous veins (ASV) in a single session. We assessed the possible risk factors for the development of a hypersensitivity reaction including the amount of injected adhesive, access site, treated segment, compression stocking application, and other clinical factors. For the statistical analyses, data were analyzed using the IBM SPSS Statistics ver. 22.0 (IBM Co., Armonk, NY, USA). P-value <0.05 was considered statistically significant. Results: During the study period, 190 saphenous veins were treated in 100 patients. Sixty-four (64%) patients were female. The mean age was 55.5 ± 12.8 years (19-84). Complete occlusion was achieved in all patients. After CAC, the mean visual analogue scale (VAS) was 2.59 and 0.32 on postoperative 0 and 7 days, respectively (P < 0.001). Post-treat-ment CHAIR occurred in 5 (5%) patients. The significant risk factors for the development of CHAIR were younger age, GSV treatment, and below-the-knee access site for the introduction of a catheter. Conclusion: CHAIR occurred when the adhesive was injected at the below-the-knee GSV segment. The mechanical irritation due to knee joint movement might be a possible mechanism for the development of the hypersensitivity reaction.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声引导下氰基丙烯酸酯缝合术后复杂超敏反应和刺激反应的危险因素
目的:采用氰基丙烯酸酯闭合术(CAC)治疗隐静脉功能不全。虽然没有严重的程序或设备相关的不良事件,但治疗后复杂的超敏反应和刺激反应(CHAIR)可能是一个麻烦的并发症。方法:对前瞻性收集的CAC患者资料进行回顾性分析。CAC在有症状的大隐静脉(GSV)、小隐静脉(SSV)和/或副隐静脉(ASV)患者中一次进行。我们评估了可能发生过敏反应的危险因素,包括注射胶粘剂的量、接触部位、治疗节段、压缩储存应用和其他临床因素。对于统计分析,使用IBM SPSS Statistics ver对数据进行分析。22.0 (IBM Co., Armonk, NY, USA)p值<0.05认为有统计学意义。结果:研究期间,100例患者共治疗190条隐静脉。64例(64%)为女性。平均年龄55.5±12.8岁(19 ~ 84岁)。所有患者均达到完全闭塞。CAC术后第0天和第7天视觉模拟评分(VAS)分别为2.59和0.32 (P < 0.001)。5例(5%)患者出现治疗后椅子。发生椅子的重要危险因素是年龄更小,GSV治疗,以及在膝关节以下的通路部位引入导管。结论:胶粘剂在膝下GSV段注射时发生椅子。膝关节运动引起的机械刺激可能是过敏反应发生的机制之一。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
4
审稿时长
8 weeks
期刊最新文献
Treatment of Leg Ulcers Accompanied by Chronic Venous Insufficiency and Lymphedema Caused by IgG4-Related Disease Ultrasound Risk Stratification System of Thyroid Nodule Effects of Ultrasound Targeted Destruction of Echogenic Nanobubbles Containing Doxorubicin in Rat Liver Correlation of Resistive Index Values Using Spectral Doppler Ultrasound with Histopathological Results in Breast Tumors Diagnostic Utility of Artificial Intelligence in Breast Ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1