Quantitative assessment of interproximal tooth reduction performed as part of Invisalign® treatment in 10 orthodontic practices

IF 0.5 4区 医学 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Australasian Orthodontic Journal Pub Date : 2021-07-01 DOI:10.21307/AOJ-2021-019
T. Weir, Arun Shailendran, B. Kerr, E. Freer
{"title":"Quantitative assessment of interproximal tooth reduction performed as part of Invisalign® treatment in 10 orthodontic practices","authors":"T. Weir, Arun Shailendran, B. Kerr, E. Freer","doi":"10.21307/AOJ-2021-019","DOIUrl":null,"url":null,"abstract":"Abstract Background Interproximal reduction (IPR) is a treatment option for orthodontic space gain. The attainment of prescribed objectives in aligner treatment may require IPR that is accurately performed both qualitatively and quantitatively. Objective This study assesses the in vivo accuracy of IPR carried out in 10 orthodontic practices as a method of orthodontic space creation. Methods A comparison of proposed and achieved amounts of IPR completed (accuracy), the accuracy of IPR within and between upper and lower dental arches, and the accuracy of IPR within and between posterior and anterior arch segments were performed using 3-dimensional digital study models gained via Align’s® ClinCheck. Results The findings indicated that IPR was routinely underperformed by all practices studied. On average, the amount of IPR achieved represented only 44.0% of the total prescribed per tooth in the sample assessed, with a mean discrepancy of 0.16 mm per tooth. There were statistically significant differences only between the overall anterior and posterior groups (p < 0.01) and between maxillary anterior and maxillary posterior groups (p < 0.01); however, these were not clinically significant. Significant differences in IPR performance were noted between different orthodontic practices. Conclusions This study demonstrates that the clinical performance of IPR in 10 orthodontic practices consistently fails to achieve the prescribed amount often by large variations. The effect of this under-performance on clinical outcomes remains to be quantified.","PeriodicalId":48559,"journal":{"name":"Australasian Orthodontic Journal","volume":"37 1","pages":"176 - 186"},"PeriodicalIF":0.5000,"publicationDate":"2021-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australasian Orthodontic Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21307/AOJ-2021-019","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 3

Abstract

Abstract Background Interproximal reduction (IPR) is a treatment option for orthodontic space gain. The attainment of prescribed objectives in aligner treatment may require IPR that is accurately performed both qualitatively and quantitatively. Objective This study assesses the in vivo accuracy of IPR carried out in 10 orthodontic practices as a method of orthodontic space creation. Methods A comparison of proposed and achieved amounts of IPR completed (accuracy), the accuracy of IPR within and between upper and lower dental arches, and the accuracy of IPR within and between posterior and anterior arch segments were performed using 3-dimensional digital study models gained via Align’s® ClinCheck. Results The findings indicated that IPR was routinely underperformed by all practices studied. On average, the amount of IPR achieved represented only 44.0% of the total prescribed per tooth in the sample assessed, with a mean discrepancy of 0.16 mm per tooth. There were statistically significant differences only between the overall anterior and posterior groups (p < 0.01) and between maxillary anterior and maxillary posterior groups (p < 0.01); however, these were not clinically significant. Significant differences in IPR performance were noted between different orthodontic practices. Conclusions This study demonstrates that the clinical performance of IPR in 10 orthodontic practices consistently fails to achieve the prescribed amount often by large variations. The effect of this under-performance on clinical outcomes remains to be quantified.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
作为Invisalign®治疗的一部分,在10种正畸实践中进行的邻间牙齿缩小的定量评估
摘要背景近端间复位(IPR)是一种治疗正畸间隙增加的方法。在对准器治疗中达到规定的目标可能需要在定性和定量上准确地执行IPR。目的评价IPR在10例正畸实践中作为正畸间隙创造方法的体内准确性。方法采用Align 's®ClinCheck获得的三维数字研究模型,比较建议和实现的IPR完成量(准确性)、上、下牙弓内和牙弓之间的IPR准确性以及后、前牙弓段内和牙弓段之间的IPR准确性。结果研究结果表明,在所有实践中,知识产权的表现通常不佳。平均而言,在评估的样本中,达到的IPR量仅占每颗牙齿规定总量的44.0%,每颗牙齿的平均差异为0.16 mm。差异有统计学意义(p < 0.01),仅整体前、后组、上颌前、后组差异有统计学意义(p < 0.01);然而,这些都没有临床意义。不同的正畸方法在IPR表现上有显著差异。结论10例正畸患者的IPR临床表现均达不到规定量,且差异较大。这种表现不佳对临床结果的影响仍有待量化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Australasian Orthodontic Journal
Australasian Orthodontic Journal Dentistry-Orthodontics
CiteScore
0.80
自引率
25.00%
发文量
24
期刊介绍: The Australasian Orthodontic Journal (AOJ) is the official scientific publication of the Australian Society of Orthodontists. Previously titled the Australian Orthodontic Journal, the name of the publication was changed in 2017 to provide the region with additional representation because of a substantial increase in the number of submitted overseas'' manuscripts. The volume and issue numbers continue in sequence and only the ISSN numbers have been updated. The AOJ publishes original research papers, clinical reports, book reviews, abstracts from other journals, and other material which is of interest to orthodontists and is in the interest of their continuing education. It is published twice a year in November and May. The AOJ is indexed and abstracted by Science Citation Index Expanded (SciSearch) and Journal Citation Reports/Science Edition.
期刊最新文献
Changes in pharyngeal airway space and hyoid bone position after Bionator treatment of skeletal Class II malocclusions Unbalanced cartilage calcification during development contributes to the formation of irregular articular surfaces as revealed by micro-CT images Twenty years of clear aligner therapy: a bibliometric analysis (2002-2022) A comparison of bond strength and adhesive remnant index of 3D-printed and metal orthodontic brackets attached using different adhesives Comparison of infrazygomatic crest bone screw position using a postero-anterior cephalogram versus cone-beam computed tomography: a cross sectional study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1