Design of Soil pH Measuring Instruments Using pH Meter Sensor Module V1.1 SEN0161 Based on Arduino Uno

Gusnul H Yakin, I. M. Satriya Wibawa, I. K. Putra
{"title":"Design of Soil pH Measuring Instruments Using pH Meter Sensor Module V1.1 SEN0161 Based on Arduino Uno","authors":"Gusnul H Yakin, I. M. Satriya Wibawa, I. K. Putra","doi":"10.24843/bf.2021.v22.i02.p08","DOIUrl":null,"url":null,"abstract":"It has been successfully made a soil pH measuring instrument using pH meter sensor module V1.1 SEN0161 based Arduino Uno. The pH result is measured through the output of the pH meter sensor output value read by the 16-bit ADC. Measurement results are displayed on a 2x16 LCD. The results of calibration test tools performed against standard measuring instruments obtained regression equation y = 0.0012x - 4.0768 with x is the output of sensor output value with accuracy level includes an average deviation of 0.13 and tool precision value of 97.98%. The results of calibration test tools carried out show the measuring instruments made have a good validity (accuracy and precision).","PeriodicalId":32375,"journal":{"name":"Buletin Fisika","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Buletin Fisika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24843/bf.2021.v22.i02.p08","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

It has been successfully made a soil pH measuring instrument using pH meter sensor module V1.1 SEN0161 based Arduino Uno. The pH result is measured through the output of the pH meter sensor output value read by the 16-bit ADC. Measurement results are displayed on a 2x16 LCD. The results of calibration test tools performed against standard measuring instruments obtained regression equation y = 0.0012x - 4.0768 with x is the output of sensor output value with accuracy level includes an average deviation of 0.13 and tool precision value of 97.98%. The results of calibration test tools carried out show the measuring instruments made have a good validity (accuracy and precision).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于Arduino Uno的pH计传感器模块V1.1 SEN0161土壤pH测量仪的设计
使用基于Arduino Uno的pH计传感器模块V1.1 SEN0161成功制作了土壤pH测量仪。pH值结果通过16位ADC读取的pH计传感器输出值的输出进行测量。测量结果显示在2x16 LCD上。校准测试工具对标准测量仪器的测试结果得到回归方程y=0.0012x-4.0768,其中x是传感器输出值的输出,精度水平包括0.13的平均偏差和97.98%的工具精度值(准确度和精密度)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
期刊最新文献
Study on the Relationship between Hotspots and Air Pollution Standard Index Based on Carbon Monoxide Concentration in West Kalimantan Analisis Fase Karbon Pada Pemutih Gigi Berbasis Arang Aktif Tempurung Kelapa Dengan Metode Difraksi Sinar-X (XRD) Identification of Metal Content in Water Samples from Natural Hot Water Sources in Ulumbu Desa Wewo Kecamatan Satar Mese Center Manggarai Regency Optical Characterization of Ferric-Doped ZnO Thin Film Deposited By Chemical Bath Deposition Method Analisis Labilitas Atmosfer Pada Peristiwa Hujan Lebat Di Wilayah Bali Selatan (Studi Kasus: Kejadian Banjir 5 dan 6 Desember 2021)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1